    1 7063-513e august 3, 2015 voyageur wood insert automatic combustion control (acc) model(s): voyageur-mbk voyageur-pmh hot surfaces! Glass and other surfaces are hot during operation and cool down. Hot glass will cause burns. • do not touch glass until it is cooled • never allow children to touch gl...

  • Page 2

    2 7063-513e august 3, 2015 voyageur table of contents safety alert key: • danger!Indicates a hazardous situation which, if not avoided will result in death or serious injury. • warning! Indicates a hazardous situation which, if not avoided may result in death or serious injury. • caution!Indicates a...

  • Page 3

    August 3, 2015 7063-513e 3 voyageur model: voyageur wood insert laboratory: intertek report no: 100116597 type: solid fuel type, listed room heater standard: ul1482 and ulc s628-93 and (um) 84-hud, mobile home approved. The quadra-fire voyageur (acc) meets the u.S. Environ- mental protection agency’...

  • Page 4

    4 7063-513e august 3, 2015 voyageur e. Non-combustible materials material which will not ignite and burn, composed of any combination of the following: - steel - plaster - brick - iron - concrete - tile - glass - slate materials reported as passing astm e 136, standard test method for behavior of me...

  • Page 5: Install Guide

    August 3, 2015 7063-513e 5 voyageur install guide 2 getting started a. Design and installation considerations before installing, determine the following: • type of chimney connector to be used · single wall, 6 inch (152mm) diameter, stainless steel, or · double wall, 6 inch (152mm) diameter, stainle...

  • Page 6

    6 7063-513e august 3, 2015 voyageur c. Negative pressure negative pressure results from the imbalance of air avail- able for the appliance to operate properly. It can be stron- gest in lower levels of the house. Causes include: • exhaust fans (kitchen, bath, etc.) • range hoods • combustion air requ...

  • Page 7

    August 3, 2015 7063-513e 7 voyageur attention installer: follow this standard work checklist this standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. Customer: date installed: lot/address: location of fir...

  • Page 8

    8 7063-513e august 3, 2015 voyageur figure 8.1 top view figure 8.2 front view figure 8.4 - side view a b 20-34/ in. (527mm) 30 in. (762mm) front 16-7/16 in. (418mm) 12-3/4 in. (324mm) 29-3/16 in. (741mm) 19-1/8 in. (486mm) 18-1/8 in. (460mm) 5 in. (127mm) 9-1/4 in. (235mm) 9-7/8 in. (251mm) c l 33 i...

  • Page 9

    August 3, 2015 7063-513e 9 voyageur note: clearances may only be reduced by means approved by the regulatory authority having jurisdiction fire risk. • comply with all minimum clearances to combustibles as specifi ed. • failure to comply may cause house fi re. Warning in canada a full length 6 inch ...

  • Page 10

    10 7063-513e august 3, 2015 voyageur thermal protection required 0 to 7 inch (0 to 178mm) 1 inch (25)mm) r value = 2.04 usa & canada only hearth height 0 to 7 inch figure 10.2 - thermal protection required factory-build solid fuel fireplace floor protection under hearth extension figure 10.1 - therm...

  • Page 11

    August 3, 2015 7063-513e 11 voyageur c. Calculating alternate floor protection material thermal conductivity: k value the k value indicates the amount of heat (in btu’s) that will fl ow in 1 hour through 1 square foot of a uniform material 1 inch thick for each degree (f) of temperature difference f...

  • Page 12

    12 7063-513e august 3, 2015 voyageur recommended location marginal location location not recommended recommended location location not recommended multi-level roofs windward leeward outside air kit termination cap figure 12.1 e. Chimney termination requirements follow manufacturer’s instructions for...

  • Page 13

    August 3, 2015 7063-513e 13 voyageur 3 ft. (91cm) minimum less than 10 ft. (305cm) 2 ft. (61cm) 3 ft. (91cm) minimum 10 ft. (305cm) to nearest roofline 2 ft. (61cm) figure 13.1 pitched roof figure 13.2 flat roof 10 ft. (305cm) or more 3 ft. (91cm) minimum less than 10 ft. (305cm) 2 ft. (61cm) minimu...

  • Page 14

    14 7063-513e august 3, 2015 voyageur 4 chimney systems d. Masonry chimney • must meet minimum standards of nfpa 211. • must have at least 5/8 inch (16mm) fi reclay lining joined with refractory cement. (installations into a clay fl ue without a stainless steel liner may reduce draw which affects per...

  • Page 15

    August 3, 2015 7063-513e 15 voyageur ul 1777 insulated stainless steel liner or other approved lining system follow manufacturer’s instructions on insulation and support for zero or other non-code clearances, follow approved liner manufacturer’s specific insulation requirements: different clearances...

  • Page 16

    16 7063-513e august 3, 2015 voyageur figure 16.1 f. Prefabricated metal chimney the chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements: • must be minimum 6 inch (152mm) inside diameter of high temperature chimney listed to ul 103 ht (2100 o f) o...

  • Page 17

    August 3, 2015 7063-513e 17 voyageur inches millimeters minimum width of cavity opening - front 32-7/8* 835 minimum width of cavity opening - rear 19-1/8* 486 minimum height 21-1/2* 546 minimum depth from front to rear 18-1/8* 460 damper smoke shelf or baffl e ember catches fire grate viewing screen...

  • Page 18

    18 7063-513e august 3, 2015 voyageur j. Ovalizing round stainless steel liners ovalizing round stainless steel liners to accommodate the liner passing through the damper region of a fi replace is an allowable and acceptable practice. Ensure that the ovalization is minimized to the extent required to...

  • Page 19

    August 3, 2015 7063-513e 19 voyageur figure 19.1 grille hinges downward remove screws & pull access assembly away from insert remove outside cover plate a (discard) figure 19.2 outside air cover plate b (discard) termination cap flex adapter items needed for installation (not supplied) • 4 inch fl e...

  • Page 20

    20 7063-513e august 3, 2015 voyageur flue collar stove pipe/liner gasket figure 20.1 b. Securing stove pipe/liner to flue collar 1. There are 4 pre-drilled holes in the fl ue collar 90 degrees apart. Attach the fl ue collar to the stove pipe/liner. If the seal is questionable use high temperature se...

  • Page 21

    August 3, 2015 7063-513e 21 voyageur corner brackets figure 21.2 figure 21.3 strain relief for blower cord and cover plug for hole in each side secure 2 sides to top mounting tabs slide into slots on firebox face secure to firebox face heat deflector 5/16 nuts attachment bar 5/16 bolts figure 21.1 e...

  • Page 22

    22 7063-513e august 3, 2015 voyageur standard size: 42-1/2 in. W x 30 in. H large size: 48 in. W x 34 in. H included in surround kit: (2) side pieces, left and right; (1) l top piece; (1) fastener package. Included in cast trim kit: (2) cast trim legs, left and right; (1) cast trim header; (2) cast ...

  • Page 23

    August 3, 2015 7063-513e 23 voyageur size: 40 in. W x 30 in. H included in surround kit: (2) side pieces, left and right; (1) l top piece; (1) fastener package. Tools needed:powered 4 to 6 inches long phillips head screw driver; pliers 1. Remove contents from box being careful not to scratch or dama...

  • Page 24

    24 7063-513e august 3, 2015 voyageur figure 24.1 blower access assembly grille hinges downward remove screws & pull access assembly away from insert hold down bracket remove screws from hold down bracket and pull blower assembly forward. Do not remove blower from the hold down bracket placement slot...

  • Page 25

    August 3, 2015 7063-513e 25 voyageur 8. The power cord is now disconnected from the blower control plate. Pull the cord out through the right side of the appliance. Route cord through retainer clip grommet 9. Insert the power cord through the left side of the appliance in the hole contains the gromm...

  • Page 26

    26 7063-513e august 3, 2015 voyageur figure 26.1 spark arestor cap roof flashing storm collar joist shield/firestop double wall connector pipe 8. Burn wood only. Other types of fuels may generate poisonous gases (e.G., carbon monoxide). 9. If unit burns poorly while an exhaust blower is on in home, ...

  • Page 27

    August 3, 2015 7063-513e 27 voyageur surround, all metal standard sp-voya-std surround, all metal, large sp-voya-lrg trim kit black trimkit-4331-bk gold trimkit-4331-gd nickel trimkit-4331-nl trim kit black trimkit-5134-bk gold trimkit-5134-gd nickel trimkit-5134-nl surround,cast-metal standard sp-v...

  • Page 28

    28 7063-513e august 3, 2015 voyageur b. Service and maintenance log date of service performed by description of service.

  • Page 29

    August 3, 2015 7063-513e 29 voyageur.

  • Page 30

    30 7063-513e august 3, 2015 voyageur.

  • Page 31

    August 3, 2015 7063-513e 31 voyageur.

  • Page 32

    32 7063-513e august 3, 2015 hearth & home technologies 1445 north highway colville, wa 99114 division of hni industries we recommend that you record the following pertinent information for your heating appliance. Date purchased/installed: serial number: location on appliance: dealership purchased fr...