Ac-35ch-ff bio nordic ac-35ch-fc bio iceberg ac-51ch-fc bio iceberg.
Notices for installation install indoor unit install outdoor unit check after installation and test operation 1 6 8 10 12 15 18 21 installation service 9 contents operation and maintenance safety precautions notices for use names of each part clean and care troubleshooting note: all the pictures in ...
Safety precautions incorrect installation or operation by not following these instructions may cause harm or damage to people, properties, etc. The seriousness is classified by the following indications: caution this symbol indicates the possibility of injury or damage to properties. This symbol ind...
The air conditioner must be grounded. Incomplete ground- ing may result in electric shocks. Do not connect the earth wire to the gas pipeline, water pipeline, lightning rod, or telephone earth wire. Pull out the plug (or cut off the main power switch) when the unit is not in use for long time so as ...
Don't install air conditioner in a place where there is flammable gas or liquid. The distance between them should above 1m. It may cause fire. Above 1m don't use liquid or corrosive cleaning agent wipe the air conditioner and sprinkle water or other liquid either. No! Doing this may case electric sh...
Safety precautions this product contains fluorinated greenhouse gases. Weee warning do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical applianc...
Caution ! don't apply the cold air to the body for a long time. It will deteriorate your physical conditions and cause health problems. Don’t stand on the top of the outdoor unit or place heavy things on it. This cloud cause personal injuries or damage the unit. Don’t use the air conditioner for oth...
Notes for heating * the fan of the indoor unit will not start running immediately after the heating is started to avoid blowing out cool air. * when it is cold and wet outside, the outdoor unit will develop frost over the heat exchanger which will compromise the heating capacity. This is when the ai...
* if the remote controller is lost or broken, use force switch button to operate the air conditioner. * if this button is pushed with the unit off, the air conditioner will operate in auto mode. * if this button is pushed with the unit on, the air conditioner will stop running. Emergency operation 1...
Ifeel force switch power cord pipe protection ring air inlet indoor unit panel air inlet grille air filter air louver air vent air outlet connecting pipe drain hose air inlet air outlet air outlet grille outdoor unit remoter controller note: all the pictures in this manual are just schematic diagram...
Clean the panel when the panel of the indoor unit is contaminated, clean it gently with a wrung towel using tepid water below 45℃, and do not remove the panel while cleaning. Clean the air filter ■ remove the air filter 1. Use both hands to open the panel for an angle from both ends of the panel in ...
■ mount the filter 1. Check whether all the air inlets and outlets of the units are unblocked. 2. Check whether there is blocking in the water outlet of the drain pipe, and immediately clean it up if any. 3. Check the ground wire is reliably grounded. 4. Check whether the remote control batteries ar...
Remote controller is not available. ● is the remote controller out of effective distance to the indoor unit? ● are there any obstructions between the controller and the signal receptor? ● is the battery exhausted? Indoor unit does not operate immediately when the air conditioner is restarted. There ...
Important notices ■ before installating, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may not solved,due to discommodious contact. ■ the air conditioner must be installed by professionals according to the nati...
Electrical safety requirements ● be sure to use the rated voltage and air conditioners dedicated circuit for the power supply, and the power cord diameter must meet the national requirements. ● when the maximum current of air conditioner is ≥16a, it must use the air switch or leakage protection swit...
● the connection method of the air conditioner and the power cord and the interconnection method of each independent element shall be subject to the wiring diagram affixed to the machine. ● the model and rating value of the fuse shall be subject to the silkscreen on corresponding controller or fuse ...
1. Make a hole with an electric hammer or a water drill at the predetermined position on the wall for piping, which shall slant outwardly by 5°-10°. 2. To protect the piping and the cables from being damaged running through the wall, and from the rodents that may inhabit in the hollow wall, a pipe p...
1. Depending on the position of the unit, the piping may be routed sideway from the left or the right ( fig 1 ), or vertically from the back( fig 2 )(depending on the pipe length of the indoor unit). In the case of sideway routing, cut off the outlet cutting stock of the opposite side. 2. The power ...
Fixing the indoor unit 1. Hang the indoor unit on the peg board, and move the unit from left to right to ensure that the hook is properly positioned in the peg board. 2. Push toward the lower left side and the upper right side of the unit toward the peg board, until the hook is embedded in the slot ...
A left installation feet right installation feet air inlet h w1 b d air outlet w2 dimension drawing of outdoor unit installation 20cm above space to the obstruction 10cm above air in side 30cm above space to the obstruction 200cm above air out side 30cm above connect the outdoor unit with connecting...
1.Loosen the screws and remove e-parts cover from the unit. 2.Connect the cables respectively to the corresponding terminals of the terminal board of the outdoor unit (see the wiring diagram), and if there are signals connected to the plug, just conduct butt joint. 3.Ground wire: remove the groundin...
Expelling the air after the pipe side connection is complete, proceed as follows. ★outdoor unit refrigerant discharging method quickly tighten and connect the nut. The installing torque is the same as that of the gas end of the indoor unit. Fully open the spindles of the liquid end and of the other ...
Test operation preparation ※v erify that all piping and connection cables are well connected. ※c onfirm that the values at the gas side the liquid-side are fully open. ※c onnect the power cord to an independent power socket. ※i nstall batteries in remote control. Test operation method 1. Turn on the...
Set temperature(℃) 自动 自 动 自动 制冷 制 冷 制冷 除湿 除 湿 除湿 制热 制 热 制热 set on/off mode clean speed sleep health strong swing dust feeling fungusproof screen timer auto fan cool high dry mid heat low air-conditioner remote controller instructions ● read this “instructions” carefully so that you can use the air-c...
Usage--------------------------------------------------------- fix batteries ---------------------------------------------- night luminous function of remote controller ---- automatic operation mode------------------------------ attention ----------------------------------------------------- buttons...
Buttons description set temperature(℃) 自 动 自 动 自 动 制 冷 制 冷 制 冷 除 湿 除 湿 除 湿 制 热 制 热 制 热 set on/off mode clean speed sleep strong swing feeling dust fungusproof screen timer auto fan cool high dry mid heat low 1 8 10 12 2 3 4 5 6 7 14 13 11 9 1.“on/off” button you can start or stop the air-conditioner...
2 press this button can be used to set the feeling function. The lcd shows the actual room temperature when the function set and it shows the setting temperature when the function cancelled. This function is invalid when the appliance at the fan mode. 4.“feeling” button 5.“health” button when it dis...
3 press the “+”or “-”button,you can set the temperature range from ℃ ℃ 16 to 32 ,display will change when you touch the button. 8.“ ”or “ ” button △ △ 9.“clean” button a. When remote controller is at the off state, press clean “ ” button, the wind guiding bars turn to initial postions for cooling, t...
4 12.“swing” button press this button, the horizontal wind direction vanes can swing automatically, when you have the desired vertical wind direction, press it again, the horizontal wind direction vanes will be stopped at the situation of your choice. 13.“dust” button this button is invalid. 14.“fun...
5 fix batteries 1.Slide open the cover according the direction indicated by arrowhead. 2.Put into two brand new batteries (7#), position the batteries to right electric poles (+&-). 3.Put back the cover. Automatic operation mode 1.Press the mode button, select the automatic operation mode. 2.Press t...
6 △ △ fan operation mode drying operation mode 1.Press the mode button, select the cooling or heating operation mode. 2.Press the speed button, you can select fan speed. You can select fan speed from low, mid, high. 3.Press the on/off button, the operation indicator is on, the air-conditioner starts...
7 1.Aim the remote controller towards the receiver on the air- conditioner. 2.The remote controller should be within 8 meters away from the receiver. 3.No obstacles between the remote controller and receiver. 4.Do not drop or throw the remote controller. 5.Do not put the remote controller under the ...