Quanta s100-l11sl 1u server user's guide date modified: october 18, 2012 5:15 pm document version: 1.0
C onventions conventions several different typographic conventions are used throughout this manual. Refer to the following examples for common usage. Bold type face denotes menu items, buttons and application names. Italic type face denotes references to other sections, and the names of the folders,...
A cronyms acronyms [0.3.1] t erm d efinition a/d analog to digital acpi advanced configuration and power interface asf alerting standard forum asserted active-high (positive true) signals are asserted when in the high electrical state (near power potential). Active- low (negative true) signals are a...
A cronyms ipmi intelligent platform management interface itp in-target probe kb 1024 bytes. Kcs keyboard controller style kvm keyboard, video, mouse lan local area network lcd liquid crystal display lct lower critical threshold led light emitting diode lnct lower non-critical threshold lnrt lower no...
A cronyms smm server management mode sms server management software snmp simple network management protocol sol serial over lan uart universal asynchronous receiver/transmitter uct upper critical threshold udp user datagram protocol unct upper non-critical threshold unrt upper non-recoverable thresh...
S afety i nformation safety information important safety instructions read all caution and safety statements in this document before performing any of the instructions. Warnings heed safety instructions: before working with the server, whether using this manual or any other resource as a refer- ence...
S afety i nformation with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool used to remove a jumper, or the ...
R evision h istory revision history refer to the table below for the updates made to this manual. Copyright copyright © 2012 quanta computer inc. This publication, including all photographs, illustrations and software, is pro- tected under international copyright laws, with all rights reserved. Neit...
About the server chapter 1.
A bout the s erver i ntroduction 1-1 1.2. Introduction s100-l11sl is a 1u server with the following major features: chipset intel ® c204 (cougar point) processor intel ® xeon ® processor e3-1200,e3-1200v2 & i3-2100 family, up to 95w pcie pcie x8 g3(ivy bridge only) low profile, md-2 slot memory up t...
A bout the s erver s ystem f eatures 1-2 pcie expansion slot (1) pcie x8 g3(ivy bridge only) low profile, md-2 slot sw raid options intel ® rste sata raid 0/1/10/5 hw raid options n/a network (4) intel (hartwell) 82574l rj45 gbe ports (1) intel 82599 10gb sfp+ (optional) management port (1) dedicate...
A bout the s erver p ackage c ontents 1-3 1.3. Package contents (1) 1u server chassis (4) dummy dimms (1) power supply (1) power cord utility cd (technical guide included) rail kit.
A bout the s erver a t our of the s ystem 1-4 1.4. A tour of the system system overview system component overview 4 3 1 5 2 6 component overview n o . I tem d escription 1 3.5” hdds 12 3.5” hard disk drive (hdd) 2 hdd board 3 fans fan module 4 main board 5 fixed psu fixed power supply unit (psu) 6 2...
A bout the s erver s ystem f ront v iew 1-5 system front view system front view control panel control panel system front view no feature description 1 control panel control system control panel features n o . I con n ame yyz d escription 1 reset button base system on push button to reset system 2 hd...
A bout the s erver s ystem r ear v iew 1-6 system rear view configuration system rear view i/o features system rear i/o view system rear view n o f eature d escription 1 psu main power supply unit (psu) 2 mainboard mainboard (mb) 1 2 system rear i/o view n o f eature d escription 1 nic1/nic2 1 g or ...
A bout the s erver p ower s ub -s ystem 1-7 power sub-system psu to mainboard module description a system has two power supply units (psu). Within the chassis are two power distribution boards (pdb), one per psu. Each psu supplies power to two mainboard modules as indicated in the preceding illustra...
A bout the s erver led s tatus d efinitions 1-8 control panel led hdd led control panel led description n o n ame s tatus d escription 3 bmc led green lan link to nic5(82599) or nic6(9303), only. Green blink- ing lan link to nic5(82599) or nic6(9303) active, only. Off nic5(82599) and nic6(9303) do n...
Installation and assembly safety instructions chapter 2.
I nstallation and a ssembly s afety i nstructions i nstallation a ssembly s afety i nstructions 2-1 2.1. Installation assembly safety instructions guidelines the power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or ...
I nstallation and a ssembly s afety i nstructions g uidelines 2-2 safety steps: whenever you remove the chassis covers to access the inside of the system, follow these steps: 1. Turn off all peripheral devices connected to the system. 2. Turn off the system by pressing the power button. 3. Unplug al...
I nstallation and a ssembly s afety i nstructions g uidelines 2-3 for proper cooling and airflow, always reinstall the chassis covers before turning on the system. Operating the system without the covers in place can damage system parts. To install the covers: 1. Check first to make sure you have no...
I nstallation and a ssembly s afety i nstructions g uidelines 2-4 the system is designed to operate in a typical office environment. Choose a site that is: clean and free of airborne particles (other than normal room dust). Well ventilated and away from sources of heat including direct sunlight. Awa...
Safety information chapter 3.
S afety i nformation s erver s afety i nformation 3-1 3.1. Server safety information to reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warn- ings and precautions in this guide before installing or maintain- ing your server product. ...
S afety i nformation i ntended a pplication u ses 3-2 intended application uses this product was evaluated as information technology equip- ment (ite), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product...
S afety i nformation s ite s election 3-3 site selection the system is designed to operate in a typical office environ- ment. Choose a site that is: clean, dry, and free of airborne particles (other than nor- mal room dust). Well-ventilated and away from sources of heat including direct sunlight and...
S afety i nformation p ower and e lectrical w arnings 3-4 power and electrical warnings power cord warnings if an ac power cord was not provided with your product, pur- chase one that is approved for use in your country. Caution! T he power button , indicated by the stand - by power mark - ing , doe...
S afety i nformation s ystem a ccess w arnings 3-5 system access warnings caution! T he power supply cord ( s ) is / are the main disconnect device to ac power . T he socket outlet ( s ) must be near the equipment and readily accessible for disconnection . Caution! T he power supply cord ( s ) must ...
S afety i nformation r ack m ount w arnings 3-6 rack mount warnings the following installation guidelines are required by ul for maintaining safety compliance when installing your system into a rack. The equipment rack must be anchored to an unmovable sup- port to prevent it from tipping when a serv...
S afety i nformation e lectrostatic d ischarge (esd) 3-7 reliable earthing - reliable earthing of rack-mounted equip- ment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.G. Use of power strips). Electrostatic di...
S afety i nformation o ther h azards 3-8 cooling and airflow laser peripherals or devices caution! C arefully route cables as directed to minimize airflow blockage and cooling problems . F or proper cooling and airflow , operate the system only with the chassis covers installed . O perating the syst...
Regulatory and compliance infor- mation chapter 4.
R egulatory and c ompliance i nformation e lectromagnetic c ompatibility n otices 4-1 4.1. Electromagnetic compatibility notices fcc verification statement (usa) this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause ha...
R egulatory and c ompliance i nformation e urope (ce d eclaration of c onformity ) 4-2 europe (ce declaration of con- formity) this product has been tested in accordance too, and complies with the low voltage directive (73/23/eec) and emc directive (89/336/eec). The product has been marked with the ...
R egulatory and c ompliance i nformation r estriction of h azardous s ubstances (r o hs) c ompliance 4-3 modem telecommunication circuitry must be ul listed. In addition, the modem must have the appropriate telecom- munications, safety, and emc approvals for the region in which it is sold. Periphera...
R egulatory and c ompliance i nformation p roduct r egulatory c ompliance m arkings 4-4 4.2. Product regulatory compliance markings this product is marked with the following product certification markings: product regulatory compliance markings r egulatory c ompliance r egion m arking culus listing ...