QUANTA S200-X12TS User Manual

Manual is about: S200 Series 2-Socket General Purpose 1U Server

Summary of S200-X12TS

  • Page 1

    Stratos s200 series s200-x12ts 2-socket general purpose 1u server 8vhuv guide document version: 1.0

  • Page 2: Conventions

    C onventions conventions several different typographic conventions are used throughout this manual. Refer to the following examples for common usage. Bold type face denotes menu items, buttons and application names. Italic type face denotes references to other sections, and the names of the folders,...

  • Page 3: Acronyms

    A cronyms acronyms t erm d efinition a/d analog to digital acpi advanced configuration and power interface asf alerting standard forum asserted active-high (positive true) signals are asserted when in the high electrical state (near power potential). Active- low (negative true) signals are asserted ...

  • Page 4

    A cronyms ipmi intelligent platform management interface itp in-target probe kb 1024 bytes. Kcs keyboard controller style kvm keyboard, video, mouse lan local area network lcd liquid crystal display lct lower critical threshold led light emitting diode lnct lower non-critical threshold lnrt lower no...

  • Page 5

    A cronyms smm server management mode sms server management software snmp simple network management protocol sol serial over lan uart universal asynchronous receiver/transmitter uct upper critical threshold udp user datagram protocol unct upper non-critical threshold unrt upper non-recoverable thresh...

  • Page 6: Safety Information

    S afety i nformation safety information important safety instructions read all caution and safety statements in this document before performing any of the instructions. Warnings heed safety instructions: before working with the server, whether using this manual or any other resource as a refer- ence...

  • Page 7

    S afety i nformation with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool used to remove a jumper, or the ...

  • Page 8: Revision History

    R evision h istory revision history refer to the table below for the updates made to this manual. Copyright copyright © 201 4 quanta computer inc. This publication, including all photographs, illustrations and software, is pro- tected under international copyright laws, with all rights reserved. Nei...

  • Page 9: About The Server

    About the server chapter 1.

  • Page 10: 1.1. Introduction

    A bout the s erver i ntroduction 1-1 1.1. Introduction main features quanta stratos s200-x12ts is a 2-socket general purpose 1u server, supporting two intel ® xeon ® processor e5-2400 family and twelve ddr3 dimm slots. It is designed with opti- mized cost suitable for fast growing small and medium b...

  • Page 11

    A bout the s erver m ain f eatures 1-2 memory (12) ddr3 800/1066/1333/1600 mhz ecc udimm/rdimm/lrdimm slots per node, up to 384 gb storage 2.5” 1 to 1 sku (10) 2.5" hot-plugable hdd(mezz *8+ ahci *2 6gb) + (2) fixed sataii (ahci 3gb) or ssd (ahci 3gb) (1) usb flash module for os installation per nod...

  • Page 12

    A bout the s erver m ain f eatures 1-3 hw raid options 2.5” 1 to 1 sku / 3.5” 1 to 1 sku quanta lsisas2108/2208 pd-8 mezzanine card for raid 0/1/10/5 (optional) quanta lsisas2108/2208 pd-8 mezzanine card + lsi raid 6 key for raid 0/1/10/5/6/ 50/60 (optional) 2.5” expander sku quanta lsisas2108/2208 ...

  • Page 13: 1.2. Package Contents

    A bout the s erver p ackage c ontents 1-4 1.2. Package contents the following list includes the package components: 1u chassis system mainboard modules 2 x processor heatsinks power supply power cord (optional) cd (technical guide included) rail kit important: server configurations may vary. Confirm...

  • Page 14: 1.3. A Tour of The System

    A bout the s erver a t our of the s ystem 1-5 1.3. A tour of the system system overview the s200-x12ts is available as a 2.5” or a 3.5” form factor. 2.5” hdd system 2.5” hdd system component overview 1 2 4 5 6 7 3 2.5” sku system component description n o . I tem d escription 1 psus 2x power supply ...

  • Page 15

    A bout the s erver s ystem f ront f eatures 1-6 3.5” hdd system 3.5” hdd system component description system front features configuration 2.5” hdd configuration 2.5” hdd configuration 3.5” sku system component description n o . I tem d escription 1 psus (2) power supply units (psu) 2 2.5” or 3.5” hd...

  • Page 16

    A bout the s erver s ystem f ront f eatures 1-7 3.5” hdd configuration 3.5” hdd configuration control panel 2.5” hdd sku control panel 2.5” hdd sku control panel features system configuration i tem n ame d escription 1 control panel control system 2 hdd bays hdds arrays 1 2 2.5” hdd sku control pane...

  • Page 17

    A bout the s erver s ystem f ront f eatures 1-8 3.5” hdd sku control panel 3.5” hdd sku control panel features 3 power but- ton with led green on based on system off, push button to psu and system on based on system on, push button to psu and system off 4 id button with led blue on, selected unit id...

  • Page 18

    A bout the s erver s ystem r ear f eatures 1-9 system rear features configuration system rear configuration i/o features system rear i/o features system rear configuration n o . I tem d escription 1 main power sup- ply unit main power supply unit (psu) 2 dummy psu dummy psu 3 mainboard mainboard (mb...

  • Page 19

    A bout the s erver p ower s ub -s ystem 1-10 power sub-system psu description a system can have two power supply units (psu). The primary psu and a redundant backup. The redundant backup is optional. Led status definitions i/o led description power supply units by model m odel psu ac i nput s200-x12...

  • Page 20

    A bout the s erver led s tatus d efinitions 1-11 lan1 led (upper) link/act green on lan link green black blinking lan access (off when there is traf- fic) -- off disconnect speed green on link speed is 100mbits/ sec amber on link speed is 1000mbits/ sec -- off off, link speed is 10mbits/sec i/o led ...

  • Page 21

    A bout the s erver led s tatus d efinitions 1-12 i/o led description - 10gbe lan i con n ame c olor c onditi on d escriptio n identification led blue on unit selected for identification -- off no identifi- cation requested lan1 led (upper) link/act green on lan link green black blinking lan access (...

  • Page 22

    A bout the s erver led s tatus d efinitions 1-13 lan led the system mainboard has one i350gbe ethernet controller and two 1gbe ports. Each rj45 connector has two built-in leds. See the following illustration and table for details. Rj45 lan connector service port (lan 3) led link/act green on lan lin...

  • Page 23

    A bout the s erver led s tatus d efinitions 1-14 control panel led 3.5” hdd sku control panel led 3.5” hdd sku control panel led 3.5 sku led f unction and b ehavior i con n ame c olor c ondition d escription power led green on system power on -- off system power off identific- aiton blue on unit sel...

  • Page 24

    A bout the s erver led s tatus d efinitions 1-15 2.5” hdd sku control panel led 2.5” hdd sku control panel led 3.5 sku led f unction and b ehavior i con n ame c olor c ondition d escription power led green on system power on -- off system power off identific- aiton blue on unit selected for identifi...

  • Page 25

    A bout the s erver led s tatus d efinitions 1-16 hdd led 3.5” hdd sku one to one ami led behav- ior note: ses-2 command card is not supported. 3.5” hdd sku one to one ami led behavior s imple led p attern s lot /d evice s tates hdd a ccess i dentificaiton s tatus led (g reen ) f ault led (r ed ) a c...

  • Page 26

    A bout the s erver led s tatus d efinitions 1-17 3.5” hdd sku one to one backplane led behavior the 4-disk backplane supports up to 4 drive slots and provides the leds that are used to light the hdd status indicators as in the fol- lowing table. 3.5” hdd sku one to one backplane led pattern o ne to ...

  • Page 27

    A bout the s erver led s tatus d efinitions 1-18 device rebuilding the disk is being written to, create a virtual disk on 400 msec off 100 msec off hdd r/w access the active led on hdd no r/w access the active led off control by hw direct to hdd active pin rebuild abort the disk has been spun down b...

  • Page 28

    A bout the s erver led s tatus d efinitions 1-19 2.5” hdd sku simple led using on board ahci/scu port (pch) note: the led pattern follows the dcs led pattern spec. Design. The led pattern is only for megaraid card. Sas2008, sas2308 mezzanine card no support full led, so only support simple led mode....

  • Page 29

    A bout the s erver led s tatus d efinitions 1-20 2.5” hdd sku one to one backplane (2.5”x10 sku) note: applies to quanta sas2008 and sas2108 mezzanine card. The pattern only on the raid mode. The backplane included ami 9086 backplane controller, led decode from sgpio singles. 2.5” hdd sku one to one...

  • Page 30

    A bout the s erver led s tatus d efinitions 1-21 device rebuilding the disk is being written to, create a virtual disk on 400 msec off 100 msec off blinking when activity rebuild abort the disk has been spun down by a user request (pre- pare to remove operation), or had a rebuild operation on it abo...

  • Page 31

    A bout the s erver led s tatus d efinitions 1-22 2.5” hdd sku expander led mode (2.5” x10 sku) the 10-disks backplane supports up to 10 drive slots and provides the leds that are used to light the hdd status indicators as shown in the following table. 2.5” hdd sku expander led mode (2.5” x10 sku) e ...

  • Page 32

    A bout the s erver led s tatus d efinitions 1-23 predicted fail (smart function) prdfail indicates that a predictive failure event has been reported by the disk on 500 msec off 500 msec off 1000 msec off 500 msec on 500 msec off 1000 msec hdd r/w access the active led on hdd no r/w access the active...

  • Page 33

    A bout the s erver led s tatus d efinitions 1-24 slot empty by expabder control the slot is empty, an unsupported disk is present, the disk has been spun down for removal (ready for removal), or a new disk has been inserted (the disk phy not ready), and the state has not been updated by the storage ...

  • Page 34

    A bout the s erver led s tatus d efinitions 1-25 2.5” hdd sku simple led mode (2.5” x10 sku) for lsi 9210-8i and sas2008, sas2308 mezzanine card. Psu led psu led 2.5” hdd sku simple led mode s imple led p attern s lot /d evice s tates hdd a ccess i ndication s tatus led (g reen ) f ault led (r ed ) ...

  • Page 35: Instructions

    Installation and assembly safety instructions chapter 2.

  • Page 36

    I nstallation and a ssembly s afety i nstructions i nstallation a ssembly s afety i nstructions 2-1 2.1. Installation assembly safety instructions guidelines the power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or ...

  • Page 37

    I nstallation and a ssembly s afety i nstructions g uidelines 2-2 safety steps: whenever you remove the chassis covers to access the inside of the system, follow these steps: 1. Turn off all peripheral devices connected to the system. 2. Turn off the system by pressing the power button. 3. Unplug al...

  • Page 38

    I nstallation and a ssembly s afety i nstructions g uidelines 2-3 the system is designed to operate in a typical office environment. Choose a site that is: clean and free of airborne particles (other than normal room dust). Well ventilated and away from sources of heat including direct sunlight. Awa...

  • Page 39: Safety Information

    Safety information chapter 3.

  • Page 40

    S afety i nformation s erver s afety i nformation 3-1 3.1. Server safety information to reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warn- ings and precautions in this guide before installing or maintain- ing your server product. ...

  • Page 41

    S afety i nformation i ntended a pplication u ses 3-2 intended application uses this product was evaluated as information technology equip- ment (ite), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product...

  • Page 42

    S afety i nformation s ite s election 3-3 site selection the system is designed to operate in a typical office environ- ment. Choose a site that is: clean, dry, and free of airborne particles (other than nor- mal room dust). Well-ventilated and away from sources of heat including direct sunlight and...

  • Page 43

    S afety i nformation p ower and e lectrical w arnings 3-4 power and electrical warnings power cord warnings if an ac power cord was not provided with your product, pur- chase one that is approved for use in your country. Caution! T he power button , indicated by the stand - by power mark - ing , doe...

  • Page 44

    S afety i nformation s ystem a ccess w arnings 3-5 system access warnings caution! T he power supply cord ( s ) must be plugged into socket - outlet ( s ) that is / are provided with a suitable earth ground . ! Caution! T o avoid personal injury or property damage , the follow - ing safety instructi...

  • Page 45

    S afety i nformation r ack m ount w arnings 3-6 rack mount warnings the following installation guidelines are required by ul for maintaining safety compliance when installing your system into a rack. The equipment rack must be anchored to an unmovable sup- port to prevent it from tipping when a serv...

  • Page 46

    S afety i nformation e lectrostatic d ischarge (esd) 3-7 reliable earthing - reliable earthing of rack-mounted equip- ment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.G. Use of power strips). Electrostatic di...

  • Page 47

    S afety i nformation o ther h azards 3-8 cooling and airflow laser peripherals or devices caution! C arefully route cables as directed to minimize airflow blockage and cooling problems . F or proper cooling and airflow , operate the system only with the chassis covers installed . O perating the syst...

  • Page 48: Mation

    Regulatory and compliance infor- mation chapter 4.

  • Page 49

    R egulatory and c ompliance i nformation p roduct r egulatory c ompliance m arkings 10-1 4.1. Product regulatory compliance markings this product is marked with the following product certification markings: product regulatory compliance markings r egulatory c ompliance r egion m arking culus listing...

  • Page 50

    R egulatory and c ompliance i nformation e lectromagnetic c ompatibility n otices 4-2 4.2. Electromagnetic compatibility notices fcc verification statement (usa) this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause ha...

  • Page 51

    R egulatory and c ompliance i nformation e urope (ce d eclaration of c onformity ) 4-3 europe (ce declaration of con- formity) this product has been tested in accordance too, and complies with the low voltage directive (73/23/eec) and emc directive (89/336/eec). The product has been marked with the ...

  • Page 52

    R egulatory and c ompliance i nformation r estriction of h azardous s ubstances (r o hs) c ompliance 4-4 modem telecommunication circuitry must be ul listed. In addition, the modem must have the appropriate telecom- munications, safety, and emc approvals for the region in which it is sold. Periphera...