Quantum Data 700 Quick Start Manual

Manual is about: Video Test Generators

Summary of 700

  • Page 1

    1.

  • Page 2

    2 model 700, 701 video test generators quick start guide getting started ........................................................................................................... 2 computer interfaces ....................................................................................................

  • Page 3

    3 getting started using ac power use only the ac adaptor provided with the generator to avoid operator injury and damage to the generator. Using battery power the generator uses six aa rechargeable nickel metal hydride (nimh) batteries, which can be re- charged about 1000 times. You may use alkaline...

  • Page 4

    4 computer interfaces rs-232 9-pin d-sub plug pin signal 1 no connection 2 data in (rx) 3 data out (tx) 4 dtr out 5 ground 6 no connection 7 rts out 8 cts in external dc power / battery recharge input warning: using an external power source other than the quantum data supplied ac power supply may in...

  • Page 5

    5 user interface lcd display the lcd window displays messages and menu options. Function buttons _ item _ 1 ______ item _ 5* _ item _ 2 ______ item _ 6 _ item _ 3 ______ item _ 7 _ item _ 3 ______ item _ 8 asterisk indicates active menu item. I tem 1 i tem 2 i tem 3 i tem 4 i tem 5 i tem 6 i tem 7 i...

  • Page 6

    6 selecting formats viewing formats by signal type press the signal type button, and then select a signal type, to list formats based on the selected signal type. Vesa red, green, blue component color video per vesa standards. (dvi-to-vga adaptor used for outputs.) ntsc/pal composite color baseband ...

  • Page 7

    7 selecting images gating outputs press the gating button to gate outputs, and to switch sync types. Note: color gating works for all images except ramp. *cutoff ________ _ graybar _ window regulate _ focus checker _ colorbar ______ dot_12 selecting images press the image button to select from list ...

  • Page 8

    8 options menu press the options button to set system-level options. Setting power save preferences pwr save:on ntsc_cal ___ calibrate clr _ fmts __ reloadfmts power save - sets power saver preference calibrate - displays calibration menu for setting rg b analog video and sync amplitudes. Appears on...

  • Page 9

    9 calibrating model 700 and 701 generators use programmable hardware to set the amplitude calibration factors for analog video outputs. These calibration factors are stored in flash eprom, and are not lost if the batteries are run down or removed. Quantum data calibrates the analog video and sync ou...

  • Page 10

    10 calibrating calibrating outputs 1. Select options > calibrate > reset to set the generator’s calibration factors to default nominal values. 2. Press options > calibrate > full scale. 3. Set the voltmeter’s scale factor to be able to measure a nominal 1000 millivolts dc. 4. Using a vga-to-bnc cabl...

  • Page 11

    11 calibrating locking calibration settings the generator uses an internal hardware jumper to enable and disable changes to calibration settings. If the options > calibration option is available, the jumper is set to enable re-calibration. To prevent users from changing calibration settings: 1. Turn...

  • Page 12

    12 _______ reading _____ monitor edid _______ complete details show details of edid after successful read back from display under test complete indicates edid data was read back correctly. Failed indicates unable to read back valid edid data learn monitor if the generator is connected to a vesa dcc-...

  • Page 13

    13 test menu press the test button to select special test operating modes. Using test sequences running test sequence manually the generator includes a test sequence, which specifies a series of format and image combinations. To run the test sequence, select test > sequence > run, and then press the...

  • Page 14

    14 running test sequence in burn-in mode select test > burn-in > run to automatically cycle through the test sequence. When the burn-in mode is stopped, you can use the menu buttons to gate video color information, change sync types, and turn all signal outputs on and off. Note: the burn-in mode dis...

  • Page 15

    15 using generator with cs-1 probe the test > cs1 probe option uses the quantum data cs-1 color sensor to measure the chromaticity and luminance (brightness) of a display. The cs-1 probe connects to the generator’s serial port. Chromaticity is shown as x,y c.I.E. Coordinates and the luminance (y) ca...

  • Page 16

    16 special tests 2. Choose a dvi video format supported by the device. 3. Press test > hdcp > start to output hdcp encrypted content. The display on the generator indicates if the test passed or failed. If the test passed, the currently selected pattern is displayed on the device under test. Noise i...

  • Page 17

    17 about vgm video generator manager (vgm) is a windows-based application for creating and editing formats and test sequences. As many as 132 formats and one test sequence can be stored in the generator. Vgm was originally created for use with quantum data 80x video generators. The 700-series genera...

  • Page 18

    18 creating video formats editing video formats you can use vgm to create your own video formats. You can start with a default format in the vgm format editor, or copy an existing format. To create a video format: 1. Connect the generator with vgm, and then double-click the generator name. 2. Click ...

  • Page 19

    19 modifying test sequence editing the test sequence the generator has a default sequence, which you can edit in vgm. One sequence can be stored in the generator at the same time. To modify the test sequence: 1. Connect the generator with vgm, and then double-click the generator name. 2. In the gene...

  • Page 20

    20 flat_wht/(r,g,b) description - fills the screen with white, blue (b), green (g) or red (r). Application - use to test chrominence. Grid decription - white crosshatch on a black background. The lines form square boxes. A single pixel dot is located in the center of each crosshatch box. Application...

  • Page 21

    21 present across the entire screen, in a large portion of the screen, or localized in a very small area. Raster description - black display (nothing being displayed). Application - useful for centering the raster on a crt. Many monitor applications require that the displayed image or text fit compl...

  • Page 22

    22 regulate description - the image has a pair of white outlined boxes which surround a blinking solid white box. Application - tests for proper high voltage regulation. Checker description - the image’s active video area is equally divided into a 6x6 checkerboard of black and white boxes. Applicati...

  • Page 23

    23 ramp description - this image provides an active video area starting from full black (+7.5 ire for ntsc) at one edge of the screen to full white (+100 ire) at or near the opposite end of the screen. Application - useful for testing pixel anomolies and chrominance. Pulsebar description - the image...

  • Page 24

    24 updating firmware the generator’s operating system firmware is stored in flash eprom, which you can update via the serial port. Firmware updates are available from http://www.Quantumdata.Com/support/downloads/. To install a firmware update: 1. Turn off generator, and connect it to your pc using a...

  • Page 25

    25 specifications video formats storage: 132 total press signal type button to view signal types. Edit method: windows-based vgm software test images (patterns) press image button to list images. Horizontal timing frequency: 1 khz to 250 khz total pixels: 144 to 4096 active range: 16 to 4096 pixels ...

  • Page 26

    26 service and support contacts to contact technical support, see http://www.Quantumdata.Com/contact/support.Asp. For factory-authorized service centers, see http://www.Quantumdata.Com/contact/locations.Asp. Model 700, 701 quick start guide 68-00198-d (12-dec-2004) copyright © 2003 by quantum data, ...

  • Page 27

    27.