Quasar HQ2061QH Install And Operation Instructions

Manual is about: Panasonic Communications Co., Ltd. Operating Instructions Room Air Conditioner HQ2061QH, HQ2081QH

Summary of HQ2061QH

  • Page 1

    Room air conditioner installation and operating instructions model hq2061qh hq2081qh english espaÑol please read these operating instructions thoroughly before using your air conditioner and keep them for future reference. For assistance, please call: 1-800-211-pana (7262) or send e-mail to consumer...

  • Page 2: Important

    Close vent open close vent open this quasar room air conditioner has been designed to keep your room comfortably cool with maximum energy efficiency and minimal noise. Este acondicionador de aire quasar ha sido diseñado para mantener la habitación a una temperatura comfortable con máxima eficiencia ...

  • Page 3: Contents

    1 contents contenido contents contenido ■ safety precautions ........................................................ 2 ~ 5 ■ precauciones de seguridad • installation precautions precauciones de instalación • operation precautions precauciones de operación ■ air conditioner installation ...............

  • Page 4: Safety Precautions

    2 • please observe the following safety precautions when using your air conditioner. Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury. • por favor observe las siguientes precauciones de seguridad cuando use su acondicionador de aire. S...

  • Page 5

    3 this sign warns of risk of death or serious injury. Esta señal indica riesgo de peligro de muerte o lesiones serias. Warning advertencia operation precautions precauciones de operaciÓn • do not modify the length of the power cord or use an extension cord. • no modifique el largo de cable de sumini...

  • Page 6: Safety Precautions

    4 this sign warns of injury or damage to property. Esta señal indica peligro de lesiones o daño a la propiedad. Operation precautions precauciones de operaciÓn safety precautions precauciones de seguridad safety precautions precauciones de seguridad caution cuidado • switch off the breaker and remov...

  • Page 7

    5 this sign warns of injury or damage to property. Esta señal indica peligro de lesiones o daño a la propiedad. Caution cuidado • do not operate the unit without the air filter or when the front intake grille has been removed. • no opere sin el filtro de aire o cuando la rejilla frontal de toma de a...

  • Page 8: Air Conditioner Installation

    6 air conditioner installation instalaciÓn del acondicionador de aire air conditioner installation instalaciÓn del acondicionador de aire caution cuidado please remove the shipping blocks fixed to the compressor and front grille before installation. Por favor remueva los tacos de envío fijados en el...

  • Page 9

    7 • hot sun rays hitting the outside surface of the cabinet will create considerable heat load. If the outside of the cabinet is in direct sunlight, consider building an awning to shade the cabinet while providing ample area for the heated air to be exhausted from the condenser (both sides) and the ...

  • Page 10: Air Conditioner Installation

    8 air conditioner installation instalaciÓn del acondicionador de aire air conditioner installation instalaciÓn del acondicionador de aire how to assemble the expandable panels (left & right) como armar los paneles expansibles (izquierdo y derecho) unscrew and remove the chassis locking brackets (1 c...

  • Page 11

    9 cabinet installation instalaciÓn del caja • expand the expandable panel fully into the grooves of the window frame, secure the expandable panel left and right and top mounting frames to the bottom of the window sash using 6 type a screws and 2 type c screws. • secure the cabinet using 2 type a woo...

  • Page 12: Air Conditioner Installation

    10 air conditioner installation instalaciÓn del acondicionador de aire air conditioner installation instalaciÓn del acondicionador de aire installation of the front grille instalaciÓn de la rejilla frontal depending upon the location of the ac outlet, route the ac cord to either the left or right si...

  • Page 13

    11 how to attach the drain pan (optional) como instalar la bandeja de drenaje (opcional) 13/32” maximum máxima de 13/32” condensed water agua condensada close vent ope n drain water drenaje de agua to get the maximum cooling efficiency, this air conditioner is designed to splash the condensed water ...

  • Page 14: Part Identification

    12 part identification identificaciÓn de los componentes part identification identificaciÓn de los componentes front intake grille rejilla frontal de toma de aire air filter (behind the front intake grille) filtro de aire (detras de la rejilla frontal de toma de aire) main unit unidad principal fron...

  • Page 15

    13 off o low cool low fan high fan high cool thermostat 10 9 8 7 6 5 4 3 1 2 main control panel control del panel principal main control knob perilla del control principal off o low cool low fan high fan high cool thermostat control knob perilla del control de termostato thermostat 10 9 8 7 6 5 4 3 ...

  • Page 16: Air Conditioner Operation

    14 off o low cool low fan high fan high cool thermostat 10 9 8 7 6 5 4 3 1 2 air conditioner operation operaciÓn del acondicionador de aire air conditioner operation operaciÓn del acondicionador de aire 1. Open the control panel cover 1. Abra la cubierta del panel de control off o low cool low fan h...

  • Page 17: Care And Maintenance

    15 ;;; ; ;; ; ; ; ;;; ;; ; ; ; ; ;; ; ; ; ;; ; ; ;; ; ; ; ; ; ; ; ; ; ;; ; ; ; ; ; ; ;; ; ; ; ; ;; ;;; ; ; ; ; ;; ; ; ; ; ;; ; ; ;; ; ; ;; ; ;;; ; ; ; ;; ;;; ;; ; ; ; ;;;; ;; ; ;; ; ; ; ; ;; ;;; ;; ;;; ; ;;; ; ;; ; ; ; ; ;; ;;;; ; ; ; ; ; ; ; ; ; ; ; ; ; ;;;; ; ; ; ; ;; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;...

  • Page 18: Care And Maintenance

    16 dolore magna aliquam erat volutpat wisi enim veniam quis nostr ud. Hendr erit in vulputate velit elitesse molescorpu at sanconsequat dolor e desperdiciado air filter removal in order to clean the air filter, just lift up the front intake grille until it is supported by the stopper. Tilt up and pu...

  • Page 19: Energy Saving Hints

    17 avoid direct sunlight and heat ensure that curtains and drapes are always closed to keep out direct sunlight during cooling operation. Avoid heat. Evite la luz solar directa y el calor asegúrese que cortinas estén siempre cerradas para mantenerlo fuera de la luz solar directa durante la operación...

  • Page 20: Condition

    18 close vent open close vent open humm… sssssss… kack! …… possible causes of the above problems posibles causas de los problemas arriba mencionados condition condición the following sounds are normal during operation: • a low humming sound indicating that the unit is operating. • a soft clicking so...

  • Page 21: Condition

    19 • the thermostat control knob is set at below 6. • the room is too big for the unit’s cooling capacity. • the ventilation lever is set to open. • the air circulation is impeded by curtains or furniture. • after 15 minutes of operation, it is normal for the temperature difference between intake an...

  • Page 22: Product Specifications

    20 * specifications are subject to change without notice for further improvement. * las especificaciones están sujetas a cambios por mejoras sin previo aviso. Product specifications especificaciones del producto product specifications especificaciones del producto model hq-2061qh hq-2081qh modelo co...

  • Page 23

    21.

  • Page 24: Quasar Room Air Conditioner

    F563100 printed in malaysia f0010-4 panasonic consumer electronics company, division of matsushita electric corporation of america one panasonic way secaucus, new jersey 07094 quasar room air conditioner limited warranty panasonic consumer electronics company or panasonic sales company (collectively...