Quietside QSVMI-09A Service Manual

Manual is about: Trendy Series

Summary of QSVMI-09A

  • Page 1

    1 summary and features summary and features model service manual qsvmi-09a qsvmi-12a qsvmi-18a.

  • Page 3: Technical Specifications

    Model qsvmi-09a qsvmi-12a qsvmi-18a i fan motor speed (r/min) (sh/h/m/l) 1150/1050/900/750 1150/1050/900/750 1250/1050/950/800 output of fan motor (w) 20 20 20 input power of heater (w) / / / fan motor capacitor (uf) 1 1 1 fan motor rla(a) 0.26 0.26 0.26 fan type-piece cross flow fan – 1 cross flow ...

  • Page 4: Part Name

    Front panel air inlet displayer air guide board air out remote control heating cooling setting temp. Auto power/run fan dehumidify remote control receiving window water drainage pipe connection pipe and connection wire wrapping tape amplified sketch for displayer part name part name 3.

  • Page 5

    Air inlet grid mark for left outlet pipe hole top view diagram mark for right outlet pipe hole back view ceiling 4 outline and installation dimension outline and installation dimension qsvmi-09a qsvmi-12a 9.84 inch 30.32 inch 7.48 inch 7.87 inch 2.76 inch 7.87 inch.

  • Page 6

    Air inlet grid mark for left outlet pipe hole top view diagram mark for right outlet pipe hole back view ceiling qsvmi-18a 11.22 inch 32.68 inch 7.87 inch 7.87 inch 2.76 inch 7.87 inch.

  • Page 7: Electrical Circuit Diagram

    Electrical circuit diagram electrical circuit diagram 5 5 5 5 5 these circuit diagrams are subject to change without notice, please refer to the one supplied with the unit. Qsvmi-09a qsvmi-12a qsvmi-18a.

  • Page 8

    6 6 6 6 6 controller function manual and operating method controller function the unit for temperature is centigrade in this function manual. If there's fahrenheit, the transition relation is tfahrenheit =tcentigrade 1.8+32. Temperature parameter indoor ambient temperature (t amb. ) indoor copper tu...

  • Page 9

    In cooling and fan mode, after setting sleep procedure 1h, tpreset will increase 33.8 ; 2h later, tpreset will increase 35.6 , then remain the temperature, tpreset will not exceed 86 ; under heating, after setting sleep procedure 1h, tpreset will decrease 33.8 ; 2h later, tpreset will decrease 35.6 ...

  • Page 10

    4. Display 4.1 basic display (1) when the unit is energized, the display symbol display, then only power lamp is light. (2) when use remote control to turn on the unit, the running led is light, and the current setting running mode lamp displayed at the same time. Cooling: running lamp and cooling l...

  • Page 11: Dissassembly Procedures

    Disassemble front panel lift the front panel upward. Firstly, screw off a screw fixing the upper protection plate at the receiving window and remove the protection plate. Then, pull away the connection terminal. Pull the panel outward with force along the groove fixing the panel of the panel body to...

  • Page 12

    Disassemble lower guide louver manually bend the lower guide louver to loose the clasp at the guide louver. Remove the lower guide louver.(note:to remove the upper guide louver,you must open the front case first, then screw off the screws fixing the upper guide louver and the water tray , bend the u...

  • Page 13

    Operating procedures / photos loosen the three clasps, and pull upward to remove the cover of the electric box. Disassemble cover of electric box cover of the electric box clasp disassemble electric box remove the grounding wire of the evaporator. Take out the pipe temp. Sensor. Unplug the plugging ...

  • Page 14

    Operating procedures / photos evaporator clasp screw screw evaporator disassemble motor use screwdriver to unscrew the two screws fixing the motor clamp, and remove the motor clamp. Unscrew the three holding screws at the shaft sleeve, and remove the motor. Motor clamp screw screw motor axial fan.

  • Page 15

    Disassemble cross flow fan after remove the motor, pull out it from the left bearing holder. Cross flow fan bearing holder operating procedures / photos.

  • Page 16

    8 explosive view and spare parts list explosive view and spare parts list exploded view of component 1.

  • Page 17

    1 wall-mounting frame 1 2 rear case 1 3 evaporator assy 1 4 cross flow fan 1 5 ring of bearing 1 6 / / 7 drainage pipe 1 8 water tray 1 9 swing louver 12 10 swing linkage 1 1 11 swing linkage 2 1 12 front case 1 13 front panel 1 14 decorate piece 1 15 remote control yt1f 1 16 filter 2 17 receiver bo...

  • Page 18

    Exploded view of component 2.

  • Page 19

    Part code qsvmi-12a 1 wall-mounting frame 01252384 1 2 rear case 222020503 1 3 evaporator assy 01002250 1 4 cross flow fan 10352005 1 5 ring of bearing 76712015 1 6 \ \ \ 7 drainage pipe 0523001401 1 8 water tray 201820306 1 9 swing louver 105120413 12 10 swing linkage 105824397 1 11 front case `200...

  • Page 20

    Exploded view of component 3.

  • Page 21

    Part code qsvmi-18a 1 wall-mounting frame 01252004 1 2 rear case 22202329 1 3 fan bearing 76512203 1 4 screw cover 24252015 3 5 swing louverb 105120472 11 5 swing louver 10512430 1 6 swing link 1 10582057 1 7 swing link 2 10582058 1 8 water tray 20182057 1 9 guide louver (up) 10512085 1 10 guide lou...

  • Page 24

    Quietside corporation www.Quietside.Com west office 8750 pioneer blvd. Santa fe springs, ca 90670 usa phone: 562-699-6066 fax: 562-699-4351 east office 6 pine hill drive carlisle, pa 17013 phone: 886-243-6498/ 717-243-2535 fax: 717-243-7917 tx office 3001 northern cross blvd. Suite 361 fort worth, t...