Quikserv SST-4035E Service Manual - Sst-4035E

Manual is about: 15" opening

Summary of SST-4035E

  • Page 1

    Operation and maintenance procedures 2 component rack assembly 3 limit switch and door flag adjustment 4 window does not operate 5 motor runs, but door does not operate 5 door or doors stay in the open position 6 motor will run for a short period then stops 7 doors are dragging or binding 7 electric...

  • Page 2: Sst-4035E

    Operation procedures : • unlock all locking mechanisms and ensure that the doors are free of obstructions. • turn the power switch to the “on” position, located on the upper left hand corner. • proper operation of the “up-eye” unit requires the attendant to be directly in front of and over all 3 pho...

  • Page 3: Figure 2

    To remove the component rack assembly - see figure 2 : . Unplug power cord from the internal outlet. . Remove the lower 5-pin connector. 3. Disconnect the flag bracket(s) from the door bracket. 4. Loosen the two () 7/6” nuts at each end of the component rack. 5. Remove component rack assembly by sli...

  • Page 4: Figure 3

    The location of the limit switch can be adjusted by loosening the two () screws in the bracket and by moving the bracket up or down in the adjustment holes. When set properly the switch should clear the flag by approximately 1/16”. When the flag is positioned within the switch, the red led door trav...

  • Page 5: Figure 4

    Trouble probable cause probable solution 1. Motor shaft pulley or block pulley is loose tighten pulley or replace (fig. 4-d (bottom of motor) & k) 2. Broken drive belt replace the defective part (fig. 4-h) motor runs, but the door does not operate 3.Door bracket disconnected from the drive belt conn...

  • Page 6: Figure 4

    Trouble probable cause probable solution 1. Close limits switch is defective or disconnected replace or reconnect (fig. 4-e) 2. Eye assembly is unplugged or disconnected check connection points and connect (fig. 6-c) remove obstructions 4. Faulty wire connection check all connections - repair or rep...

  • Page 7: Figure 4

    Trouble probable cause probable solution clean and oil or tighten (fig. 4-l) 2. Door bracket loose tighten screws (fig. 4-m) doors are dragging or binding 1. Slide rail has dirt or debris build-up or the rail is loose trouble probable cause probable solution 1. No power to the unit check the circuit...

  • Page 8: Figure 7

    Figure 7 service manual sst-4035e 8 quikserv corp. © quikserv.Com • -800-388-8307 • fax (73) 849-5708 electrical component layout.

  • Page 9: Figure 7

    Figure 7 a service manual sst-4035e 9 quikserv corp. © quikserv.Com • -800-388-8307 • fax (73) 849-5708 electrical component layout after serial no. 38600

  • Page 10: Figure 8

    Key no. Part no. Description a 4413 on/off switch c 4425 1/2a 250v in line fuse d 5615 drive motor assembly e/j 4451 limit switch (2) f 4460 p.C. Board h 1052 drive belt i 4401 capacitor l 1917 slide n 5548 complete component rack p 4430 500ma 250v p.C. Board fuse figure 8 service manual sst-4035e 0...

  • Page 11: Figure 9

    Key no. Part no. Description a 5602 thru-beam eye set assembly a 5604 photo-electric up-eye set assembly (shown above) key no. Part no. Description b 4414 open / close switch c 5323 protective plastic ring d 4403 set of thru-beam eyes d 4404 set of up-eyes figure 9 service manual sst-4035e quikserv ...

  • Page 12: Warranty Service Policy

    1. Quikserv corp. Must be notified of a war - ranty situation before any work is performed. Otherwise, quikserv corp will not be respon- sible to pay for unauthorized work. . Quikserv corp. Requires the following on each invoice submitted: an itemized account of work performed detailing hours charge...