QUINCY HYDRONIC TECHNOLOGY Riva ADVANCE COMBI User Manual And Instructions - 4. Lcd General Features
10 RIVA ADVANCE COMBI USER MANUAL
4. LCD General Features
The LCD (5 in Fig. 3.2) give detailed indication regarding the operation of the boiler.
Figure 4.1
LEGEND
The symbol indicates that the boiler
can be directly reactivated by the
user, by pressing the reset button
The symbol indicates that the fault
requires intervention on behalf of
specialised technical assistance
All symbols represented with lines
that surround them, indicate that the
symbol is flashing
SIGNAL DISPLAYED BY THE LCD
LCD
FUNCTION
E01 +
Lack of burner ignition on safety
lockout
E02 +
Safety thermostat intervention
lockout
E03 +
General lockout
E10 +
Flue probe intervention lockout
E11 +
Flame detection error
E04 +
Faulty primary circuit (no water or
absence of flow)
E05 +
Faulty fan control system
E06 +
Faulty c.h. temp. probe NTC
E07 +
Faulty d.h.w. temp. probe NTC
E08 +
Faulty external temp. probe NTC
E09 +
Faulty flue temp. probe NTC
(interruption)
L01
Primary circuit temp. limit during
D.h.w. operation
The flashing symbol indicates
the communication between LCD
and the card
Boiler in winter mode
(C.h.+ D.h.w.)
Boiler in summer mode (D.h.w.)
Boiler in winter standby
Hot water + heating mode
(symbol flashing)
Boiler in summer standby
Hot water mode
(symbol flashing)
OFF
Boiler powered and selector OFF
(symbol flashing)
bar
Remote connected
bar
External temperature control
probe connected