Quintezz EGP-Q48 User Manual - D/c Operation
- GB-6 -
•
After sufficient cooling (approximately 5 hours), the thermostat position can be
set to a lower temperature. the thermostat will now automatically regulate the
set temperature.
To turn off
•
turn thermostat knob (10) anticlockwise to position MiN (a slight resistance will
be felt just before this position).
•
Pull out mains plug.
D/C OPERATION
Do not use any additional form of energy (mains/gas).
there is a replaceable 10 A fuse inside the cigarette plug. if the cigarette plug is not used,
a safety fuse must be installed in the electricity supply between battery and refrigerator in
a duct.
24 v: maximum 7.5 amps.
cable cross section
Max. cable length
2.5 mm²
until
5 m
4.0 mm²
until
8 m
6.0 mm²
until
12 m
it is not necessary to consider the polarity when connecting the unit. check that the
battery voltage corresponds with the line-voltage data on the cooling unit type-plate. if
no battery is used independently of the vehice, the cooling unit is only to be used when
the vehicle is in motion, since, when the engine is not running, the battery can discharge
to such an extent that the engine will not restart. recommendation: Before a journey, pre-
cool the unit using the supply voltage.
To turn on
the car plug fitted to the connecting cable is to be plugged into the socket/cigar lighter.
When using battery operation, the cooling performance is not thermostatically regulated,
i.e. knob (10) is ineffective.
Turn off unit
Pull out plug from socket.
LIQUID GAS OPERATION
Do not use any additional form of energy (mains/battery). the unit must not be connected
to town or natural gas pipelines. It is only suitable for use with propane/butane gas (e.g.
calor Gas, camping Gaz, caravangas, etc).
the specified gas-connection pressure is given in mbar on the type plate (see back of
appliance). it is important that a non adjustable pressure regulator is used to reduce the
pressure in the gas cylinder to the operating pressure specified on the rating-plate, no other
pressure may be used.
Needle valve operated gas control taps are NOT suitable for use with this appliance and
must not be used as a substitute for a pressure regulator.