Quooker Combi E Installation Manual - page 16
COLD
COLD
Connecting water
• Note: The COMBI E operates under mains water pressure and must always
be fitted with the supplied inlet combination and pressure reducing valves.
• The Nordic single tap, the Fusion or the Flex tap must be installed according
to the locally applicable regulations.
• The inlet combination valve will release drips of expansion water while the
water in the tank is heating up in order to regulate the pressure inside the
tank.
• Position the inlet combination valve as high as possible to create a sufficient
height distance between the valve and the point where the waste hose connects
to the waste pipe. This is necessary to allow the expansion water to flow away
and to prevent water from backing up from the waste pipe (see figure at step D4).
1 Fitting pressure
reducing valve
Close the main shut-off valve. Fit the
pressure reducing valve to the T-joint
and subsequently to the cold water pipe
(Ø 15 mm). Note: The pressure reducing
valve must be fitted in the correct direc-
tion . Fit the cold water inlet hose of the
mixer tap the Fusion or the Flex tap to
the T-joint with the inlet hose screen.
2 Fitting inlet
combination valve
Connect the inlet combination valve
to the pressure reducing valve with a
piece of copper piping (Ø 15mm).
3 Fitting mixing
valve
Connect the mixing valve to the inlet
combination valve with the large fibre
washer supplied. Allow for the tempe-
rature setting knob. Connect the hot
water inlet hose of the mixer tap, the
Fusion or the Flex tap to the mixing
valve with the inlet hose screen.
4 Temperature
setting
Turn the temperature setting knob of
the mixing valve to the temperature
you require (between 40°C and 60°C).
1
2
3
4
C