10
Drilling hole
• The tap should be located in one corner of the basin(s).
• N.B. It must be possible to move the tap outlet freely up and down.
When the outlet is in its lowest position it projects approx.25 cm below the sink.
Bear this in mind when fitting the inlet combination, sockets and the like.
• The radius of the outlet is a good 16 cm from the centre of the tap hole,
which determines how far the outlet extends into the basin.
1
A
1 Drilling hole
Allowing for the basin and the mixer
tap, select a suitable location for the
Quooker tap (see examples). Using the
correct drill bit, drill a hole of 32-35
mm in the sink.
164
±
70
Ø50
Maximum thickness 50
Hole Ø32-35
d=50
Basin
Max. 256
Dimensions in mm
Quooker
tap
Q
M
Mixer
tap