RAB Lighting floodinator Installation Instructions - Floodinator
FLOODINATOR
TM
INSTALLATION INSTRUCTIONS
®
Page 3
TROUBLESHOOTING
1. Is the proper lamp is installed? Check the wattage
and ANSI code on the fi xture label against markings
on the lamp. Refer to Replacement Lamp table
above for verifi cation.
2. Make sure the lamp is not defective. Try a lamp
known to be in operating condition.
3. Check that the line voltage at fi xture is correct. Refer
to wiring directions.
4. Is there voltage at the lamp socket? If there is no
voltage, check all connections.
5. Is the fi xture grounded properly?
6. Is the photocell functioning properly (if used)
?
Note: These instructions do not cover all details or variations
in equipment nor do they provide for every possible situation
during installation, operation or maintenance.
FN-IN-0408
REPLACEMENT LAMPS AND
BALLASTS
RAB Lamp
ANSI
RAB Ballast
Wattage Catalog# Code
Catalog#
High Pressure Sodium
400 LHPS400
S51
BHPSH400QT
1000 LHPS1000
S52
BHPSH1000QT
Metal Halide
400 LMH400
M59
BMHH400QT
400PS LMH400PS
M155
BMHH400PSQ
1000 LMH1000
M47
BMHH1000QT
480V Ballasts are available, consult factory.
LAMP INSTALLATION
CAUTION: Prior to installing, check that the lamp is
the correct ANSI type and wattage. Observe lamp
manufacturer’s recommendations on lamp operation,
ballast type and burning positions.
1. Disconnect power. Make sure fi xture and lamp are
cool enough to touch.
2. Loosen (4) screws from the door of the fi xture.
Screws will remain captive to door. Open and
swing door down on hinges.
3. Fully screw lamp into socket.
4. Before closing door, make sure door gasket is
properly seated all around the door.
5. Check that all mounting bolts are tight.
6. Close door. Tighten screws.
ACCESSORIES
Wire
Guard:
GDFN
6”
Hood FNH6
12”
Hood
FNH12
Factory Installed Photo Cells
120V
Swivel
/PCS
277V
Swivel
/PCS2
480V Swivel
/PCS4
RAB fi xture designs are protected under
U.S. and International Intellectual Property laws.
Patent Pending
WIRING
All units are factory wired for 277V, except for units
with a requested 120V Photocell(“/PC”). If voltages
other than 277V are required, remove ballast cover and
rewire for the appropriate voltage.
1. Connect the black fi xture lead to the (+) LINE
supply lead.
2. Connect the white fi xture lead to the (-) COMMON
supply lead.
3. Connect the Ground wire from fi xture to supply
ground.
4. All unused leads must be capped and insulated.
Supply