RAB Lighting STL360H Installation Manual

Summary of STL360H

  • Page 1

    Specifications: switching capacity 8 amps 1000 watts incandescent and 250 watts fluorescent voltage: 120 volts protection pattern: 180° forward 360° below and to all sides time adjustment: 5 seconds to 12 minutes power consumption: 1 watt surge protection: 6000 volts cautions: turn off all power at ...

  • Page 2

    How does the super stealth 360 work? The stl360’s infrared sensor “sees” temperature changes caused by the motion of people or cars within its protection zone and turns on lights automatically. It welcomes visitors and may deter intruders. Total coverage. Two sensors in one. Two powerful detectors c...

  • Page 3

    Choosing a location the best location is where the sensor can “see” all paths of movement. The sensor may be wall or soffit mounted. As distance from the sensor increases, larger movement will be required for detection. For instance, at 10 feet, a half step will be enough, while at 50 feet several s...

  • Page 4

    Choosing a location locations near roads cars and passing traffic may activate the sensor if it is aimed at the road. To improve performance in locations near roads: • reduce sensitivity by turning the sens knob counterclockwise. • mask the lens in the direction of the traffic using the lens mask pr...

  • Page 5

    Stl360 kit assembly and wiring stl360 floodlight kits come pre-wired and assembled on the rab cu4 ez plate, allowing for mounting on round, rectangular or octagonal surface or recessed boxes. Mounting wiring stl360 kit assembly and wiring 1. Attach the universal mounting bar with the bar screws (pro...

  • Page 6

    Stl360 assembly and wiring ■ to install a stl360 sensor with separately purchased floodlights, start at #1. ■ to install stl360 pre-wired floodlight kits, see page 7. 1. Screw the threaded arms of each floodlight into the rab cu4 ez plate. ( see diagram on page 7) 2. Screw the threaded arm of the se...

  • Page 7

    Adjusting the settings time sets the time that lights will remain on after the detection zone is vacated. Adjustable from approximately 5 seconds to 12 minutes. The factory setting is 12 minutes. Photocell for night-only operation, turn the knob completely counterclockwise to (to the moon symbol). F...

  • Page 8

    Sensor modes automatic mode lights will turn on when there is movement with- in the detection zone after dusk. Evening timer mode keeps lights on for 1-8 hours after dusk. Sensor then reverts to automatic mode until dawn. If you set the evening timer mode during daylight, the sensor will be prepared...

  • Page 9

    Walk testing stl360’s full coverage pattern reduces the need for aiming and adjustment. The purpose of the walk test is to check and adjust the coverage pattern. The stl360 has a test period which allows the sensor to be walk tested day or night. To enter test mode: the sensor is in test mode when p...

  • Page 10

    1. Make sure the sensor is installed on its own dedicated circuit, free of motor loads such as hvac equipment, kitchen appliances or garage door openers. 2. It is not recommended to wire sensors in parallel. More than one sensor wired together makes them difficult to troubleshoot. Disconnect multi- ...

  • Page 11

    Technical tips: lights turn off too quickly 1. Check if sensor is being “tricked” by reflected light. If lights controlled by the sensor shine or reflect into the photocell (locat- ed behind the lens) the unit will go on briefly, see its own light, and turn off “thinking” that it is daytime: problem...

  • Page 12

    Replacement lamps stl360q1 150 watt double-ended quartz flood stl360q2 (2 lamps) 150 watt double-ended quartz flood stl360q3 300 watt double-ended quartz flood stl360h (2 lamps) 150 watt par38 stl360hb (2 lamps) 150 watt par38 note: all double ended quartz fixtures must be mounted with the lamp hori...