RAD Data Communications ASMi-52 Installation And Operation Manual

Manual is about: 2/4-Wire SHDSL Modem

Summary of ASMi-52

  • Page 1

    Instal lation and operati on manual asmi-52 2/4-wire shdsl modem version 2.9 the access company.

  • Page 3: Asmi-52

    Asmi-52 2/4 -wire shdsl modem version 2.9 installation and operation manual notice this manual contains information that is proprietary to rad data communications ltd. ("rad"). No part of this publication may be reproduced in any form whatsoever without prior written approval by rad data communicati...

  • Page 4: Limited Warranty

    Front matter installation and operation manual ii asmi-52 ver. 2.9 limited warranty rad warrants to distributor that the hardware in the asmi-52 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following th...

  • Page 5: Safety Symbols

    Installation and operation manual front matter asmi-52 ver. 2.9 iii general safety instructions the following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety s...

  • Page 6

    Front matter installation and operation manual iv asmi-52 ver. 2.9 handling energized products general safety practices do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in ...

  • Page 7

    Installation and operation manual front matter asmi-52 ver. 2.9 v the maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16a (20a for usa and canada). The circuit breaker in the building installation should have high breaking capacity and ...

  • Page 8

    Front matter installation and operation manual vi asmi-52 ver. 2.9 when using shielded or coaxial cables, verify that there is a good ground connection at both ends. The grounding and bonding of the ground connections should comply with the local codes. The telecommunication wiring in the building m...

  • Page 9: Fcc-15 User Information

    Installation and operation manual front matter asmi-52 ver. 2.9 vii fcc-15 user information this equipment has been tested and found to comply with the limits of the class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmf...

  • Page 10: Mise Au Rebut Du Produit

    Front matter installation and operation manual viii asmi-52 ver. 2.9 f ran çai s mise au rebut du produit afin de faciliter la réutilisation, le recyclage ainsi que d'autres formes de récupération d'équipement mis au rebut dans le cadre de la protection de l'environnement, il est demandé au propriét...

  • Page 11

    Installation and operation manual front matter asmi-52 ver. 2.9 ix f ran çai s certains produits peuvent être équipés d'une diode laser. Dans de tels cas, une étiquette indiquant la classe laser ainsi que d'autres avertissements, le cas échéant, sera jointe près du transmetteur optique. Le symbole d...

  • Page 12

    Front matter installation and operation manual x asmi-52 ver. 2.9 f ran çai s connexion au courant du secteur assurez-vous que l'installation électrique est conforme à la réglementation locale. Branchez toujours la fiche de secteur à une prise murale équipée d'une borne protectrice de mise à la terr...

  • Page 13: Declaration Of Conformity

    Installation and operation manual front matter asmi-52 ver. 2.9 xi declaration of conformity manufacturer's name: rad data communications ltd. Manufacturer's address: 24 raoul wallenberg st. Tel aviv 69719 israel declares that the product: product name: asmi-52 conforms to the following standard(s) ...

  • Page 15: Glossary

    Asmi-52 ver. 2.9 xiii glossary address a coded representation of the origin or destination of data. Agent in snmp, this refers to the managed system. Analog a continuous wave or signal (such as human voice). Analog loopback a testing technique that isolates faults in transmission equipment by perfor...

  • Page 16

    Front matter installation and operation manual xiv asmi-52 ver. 2.9 data information represented in digital form, including voice, text, facsimile and video. Dbm a measure of power in communications: the decibel in reference to one milliwatt (0 dbm = 1 milliwatt and -30 dbm = .001 milliwatt). Diagno...

  • Page 17

    Installation and operation manual front matter asmi-52 ver. 2.9 xv half duplex a circuit or device capable of transmitting in two directions, but not at the same time. Hdlc (high-level data link control) a synchronous, bit-oriented link layer protocol for data transmission. Frame relay is an example...

  • Page 18

    Front matter installation and operation manual xvi asmi-52 ver. 2.9 physical layer layer 1 of the osi model. The layer concerned with electrical, mechanical, and handshaking procedures over the interface connecting a device to the transmission medium. Port the physical interface to a computer or mul...

  • Page 19

    Multiplexer at one end of a communications link, a device that combines several lower speed transmission channels into a single high speed channel. A multiplexer at the other end reverses the process. Sometimes called a mux. See bit interleaving/multiplexing. Network (1) an interconnected group of n...

  • Page 20

    Single mode describing an optical wave-guide or fiber that is designed to propagate light of only a single wavelength (typically 5-10 microns in diameter). Space in telecommunications, the absence of a signal. Equivalent to a binary 0. Sync see synchronous transmission. Synchronous transmission tran...

  • Page 21: Quick Start Guide

    Quick start guide installation of asmi-52 should be carried out only by an experienced technician. If you are familiar with asmi-52, use this guide to prepare the units for operation. 1. Installing asmi-52 connecting the interfaces 1. Connect the line to the shdsl connector. 2. Connect the dte to th...

  • Page 22

    Quick start guide installation and operation manual configuring the master clock ³ to configure the master clock: • from the system configuration menu (main menu > configuration > system configuration > master clock), configure the central asmi-52 clock to external or internal and remote asmi-52 clo...

  • Page 23

    Installation and operation manual quick start guide yes by default). The units identical setting value of the local modem overrides the management commands of the remote supervisory terminal. ³ to configure e1 parameters: • from the e1 port configuration menu (main menu > configuration > port config...

  • Page 24

    Quick start guide installation and operation manual 4 configuring asmi-52 asmi-52 ver. 2.9.

  • Page 25: Contents

    Asmi-52 ver. 2.9 i contents chapter 1. Introduction 1.1 overview.................................................................................................................... 1-1 product options ......................................................................................................

  • Page 26

    Table of contents installation and operation manual ii asmi-52 ver. 2.9 initiating a control session ................................................................................. 3-9 navigating the management menus .................................................................... 3-9 correcti...

  • Page 27

    Installation and operation manual table of contents asmi-52 ver. 2.9 iii displaying the system status ........................................................................... 4-37 displaying the port status ................................................................................ 4-38 acce...

  • Page 28

    Table of contents installation and operation manual iv asmi-52 ver. 2.9 6.3 software upgrade options ......................................................................................... 6-1 6.4 prerequisites ..........................................................................................

  • Page 29: Chapter  1

    Asmi-52 ver. 2.9 overview 1-1 chapter 1 introduction 1.1 overview asmi-52 is an shdsl modem that operates in full-duplex over 2/4-wire lines and offers a cost-effective solution for delivering digital data to customer premises over existing copper cables. Asmi-52 handles multiple data rates in the r...

  • Page 30

    Chapter 1 introduction installation and operation manual 1-2 overview asmi-52 ver. 2.9 unit enclosure asmi-52 is available in a plastic, metal, or rail-mount enclosure. Applications figure 1-1 illustrates a typical asmi-52 application, in which standalone modems operate opposite each other. Figure 1...

  • Page 31

    Installation and operation manual chapter 1 introduction asmi-52 ver. 2.9 overview 1-3 4-wire public network central site nms 4-wire remote site a e1 router asmi-52 v.35 router remote site b lan router asmi-52 v.35 router e1 router asmi-52 v.35 router asmi-52 remote site c asmi-52 4-wire 2-wire 2-wi...

  • Page 32

    Chapter 1 introduction installation and operation manual 1-4 overview asmi-52 ver. 2.9 line interface asmi-52 extends the range of data transmission over 2/4-wire lines up to 7.0 km (4.3 miles), by employing shdsl tc-pam technology. Asmi-52 operation complies with the requirements of the itu-t g.991...

  • Page 33

    Installation and operation manual chapter 1 introduction asmi-52 ver. 2.9 overview 1-5 asmi-52 supports multiple data rates between the range of 64 kbps and 4608 kbps. The data rate depends on the following factors: • unit rate mode (regular or low speed) • line interface type (2-wire or 4-wire) • d...

  • Page 34

    Chapter 1 introduction installation and operation manual 1-6 overview asmi-52 ver. 2.9 multiplexer functionality • the multiplexer unit cannot be configured as a device with only a lan port. It must have a dte or ir port. • the hardware of a single unit-based product with a lan port manager is diffe...

  • Page 35

    Installation and operation manual chapter 1 introduction asmi-52 ver. 2.9 overview 1-7 co/cpe e1 serial dte lan e1+serial dte e1+lan serial dte+lan e1+lan↔e1 e1↔e1 e1↔serial dte e1↔e1+lan e1↔serial dte+lan e1+lan↔e1 e1+lan↔e1 e1+lan↔ e1+lan rial dte+lan serial dte↔e1 serial dte↔ serial dte serial dt...

  • Page 36

    Chapter 1 introduction installation and operation manual 1-8 overview asmi-52 ver. 2.9 • external, supplied by the attached dte • receive, recovered from the received line signal (cpe mode). Management asmi-52 supports the following management options: • ascii terminal or easy config hand-held devic...

  • Page 37

    Installation and operation manual chapter 1 introduction asmi-52 ver. 2.9 physical description 1-9 statistics collection asmi-52 supports shdsl and e1/t1 statistics collection and standard g.826. Alarm reporting asmi-52 alarms are relayed via a dedicated 6-pin terminal block connector. Shdsl repeate...

  • Page 38

    Chapter 1 introduction installation and operation manual 1-10 technical specifications asmi-52 ver. 2.9 1.4 functional description the asmi-52 modem consists of the following major modules: dte interface – prepares the digital data coming from the dte into a data stream for modem glue logic. In addi...

  • Page 39

    Installation and operation manual chapter 1 introduction asmi-52 ver. 2.9 technical specifications 1-11 connectors x.21: 15-pin, d-type, female v.35: 34-pin, female rs-530: 25-pin, d-type, female ethernet (10/100baset bridge with vlan support): rj-45 e1/t1 interface data rate e1: 2048 kbps t1: 1544 ...

  • Page 40

    Chapter 1 introduction installation and operation manual 1-12 technical specifications asmi-52 ver. 2.9 diagnostics loopbacks itu v.54: • local analog loopback, activated via the management software or by the dte interface signal (v.35 and rs-530 only) • remote digital loopback, activated via the ma...

  • Page 41

    Installation and operation manual chapter 1 introduction asmi-52 ver. 2.9 technical specifications 1-13 rail-mount metal enclosure height width depth weight 150 mm (5.9 in) 70 mm (2.7 in) 163 mm (6.4 in) 0.9 kg (1.9 lb) power wide range power supply 24 vdc 100–240 vac, 50/60 hz or 48/60 vdc nominal ...

  • Page 42

    Chapter 1 introduction installation and operation manual 1-14 technical specifications asmi-52 ver. 2.9.

  • Page 43: Chapter  2

    Chapter 2 installation and setup this chapter describes installation and setup procedures for the standalone asmi-52 modem. After installing the unit: • refer to chapter 3 for the operating instructions. • refer to chapter 4 for the detailed system configuration procedures using an ascii terminal co...

  • Page 44

    Chapter 2 installation and setup installation and operation manual the plastic and metal enclosures are also available in -20°–70°c (-4°–158°f) extended temperature versions (by special request). 2.2 package contents the asmi-52 package includes the following items: • one asmi-52 unit • technical do...

  • Page 45

    Installation and operation manual chapter 2 installation and setup figure 2-1. Rack mount fittings ³ to remove a rail mounted unit: 1. Insert a small flat screwdriver into the hole at the end of the spring-loaded mounting bracket at the bottom rear of the unit (see figure 2-2 .) insert screwdriver h...

  • Page 46

    Chapter 2 installation and setup installation and operation manual 2.4 connecting the interfaces figure 2-3 illustrates a typical rear panel of asmi-52 in a plastic enclosure with a 4-wire line interface, e1 dte interface, user lan interface, alarm relay port, and the control port. E1/t1 shdsl dce v...

  • Page 47

    Installation and operation manual chapter 2 installation and setup connecting to shdsl equipment the asmi-52 line interface on a standard (metal or plastic enclosure) terminates in an 8-pin rj-45 connector. On the rail-mount version, the shdsl line connector is a terminal block. ³ to connect the shd...

  • Page 48

    Chapter 2 installation and setup installation and operation manual 2.5 connecting to power asmi-52 is equipped with a dual input ac/dc power supply. Ac or dc power is supplied to asmi-52 via a standard 3-prong power input connector on the rear panel (see figure 2-3 ). Before connecting this unit to ...

  • Page 49: Chapter  3

    Chapter 3 operation this chapter provides the following information for the asmi-52 modem: • asmi-52 front-panel indicators • operating procedures (turn-on, front-panel indications, performance monitoring and turn-off) • asmi-52 default settings. Installation procedures given in chapter 2 must be co...

  • Page 50

    Chapter 3 operation installation and operation manual asmi-52 figure 3-1. Asmi-52 front panel, e1 interface (2 wire) figure 3-2. Asmi-52 front panel, e1 interface (4 wire) figure 3-3. Asmi-52 front panel, t1 interface (4 wire) asmi-52 figure 3-4. Asmi-52 front panel, dte serial interface (4 wire) fi...

  • Page 51

    Installation and operation manual chapter 3 operation table 3-1 lists and describes the front panel indicators. Table 3-1. Front panel leds name color state description pwr green on power is on tst red on a loopback test is active in a local or remote unit sync a/b red/green on (red) on (green) flas...

  • Page 52

    Chapter 3 operation installation and operation manual if the above led indications do not appear following initial power activation, refer to chapter 5 for the diagnostic test instructions. 3.3 default settings asmi-52 is managed by an ascii terminal or a pc running a terminal emulation program via ...

  • Page 53

    Installation and operation manual chapter 3 operation asmi-52 ver. 2.9 default settings 3-5 type parameter default value data 8 parity none interface dce cts =rts dsr on port control mode terminal user name – password 1234 pop alarm off security timeout 10 min call out mode none number of retries 1 ...

  • Page 54

    Chapter 3 operation installation and operation manual 3-6 configuration and management alternatives asmi-52 ver. 2.9 type parameter default value llb from dte disable rlb from dte disable e1/e1+ethernet/e1+serial dte interface framed mode unframed sync ccitt crc-4 no idle code ff units identical set...

  • Page 55

    Installation and operation manual chapter 3 operation ³ to prepare asmi-52 for network management: 1. Connect a lan network management station to the asmi-52 ethernet port designated 10/100baset. 2. Configure the host ip parameters of the asmi-52 unit via an ascii terminal. 3. Run an snmp management...

  • Page 56

    Chapter 3 operation installation and operation manual control port interface characteristics asmi-52 includes a v.24 (rs-232) asynchronous dce port, designated as control and terminating in a 9-pin d-type female connector. The control port continuously monitors the incoming data stream and immediate...

  • Page 57

    Installation and operation manual chapter 3 operation navigating the management menus this section provides a general description of the software menu operation and conventions for navigating the menus. Choosing options ³ to choose an option: • type the number corresponding to the option, and press ...

  • Page 58

    Chapter 3 operation installation and operation manual verifying the application software version before continuing the management session, verify that the unit is running version 2.8 of the application software. ³ to verify the application software version: 1. From the main menu, select inventory. 2...

  • Page 59

    Installation and operation manual chapter 3 operation 3. Enter the ip address of the asmi-52 in the address field of the browser in the following format: http:// and then press to command the browser to connect (ip address stands for the actual asmi-52 ip address which has to be assigned via an asci...

  • Page 60

    Chapter 3 operation installation and operation manual working with radview radview-ems/tdm is a user-friendly and powerful snmp-based application for management and service provisioning. It offers pseudowire service provisioning, as well as embedded element management capabilities. Radview-ems/tdm p...

  • Page 61

    Installation and operation manual chapter 3 operation figure 3-10. Inventory and configuration menus asmi-52 ver. 2.9 configuration and management alternatives 3-13.

  • Page 62

    Chapter 3 operation installation and operation manual figure 3-11. Monitoring, diagnostics and file utilities menus 3-14 configuration and management alternatives asmi-52 ver. 2.9.

  • Page 63

    Installation and operation manual chapter 3 operation 3.5 turning off asmi-52 ³ to turn off asmi-52: • remove the power cord from the power source. Asmi-52 ver. 2.9 turning off asmi-52 3-15.

  • Page 64

    Chapter 3 operation installation and operation manual 3-16 turning off asmi-52 asmi-52 ver. 2.9.

  • Page 65: Chapter  4

    Asmi-52 ver. 2.9 configuring asmi-52 for management 4-1 chapter 4 configuration 4.1 configuring asmi-52 for management the configuration of asmi-52 is performed via a menu-driven embedded software, using a standard ascii terminal or a pc running a terminal emulation application connected to the rear...

  • Page 66

    Chapter 4 configuration installation and operation manual 4-2 configuring asmi-52 for management asmi-52 ver. 2.9 entering device information the device information menu allows you to assign a name to asmi-52, define its location, and contact person. These entries may include up to 20 characters. To...

  • Page 67

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring asmi-52 for management 4-3 configuring the host parameters asmi-52 can be managed by a network management station, which is located on the lan connected to the 10/100baset port. In order to establish a proper conn...

  • Page 68

    Chapter 4 configuration installation and operation manual 4-4 configuring asmi-52 for management asmi-52 ver. 2.9 3. Type a number corresponding to a subnet mask of the already defined network management station, and enter a new value. 4. Repeat step 2 and step 3 to define additional management stat...

  • Page 69

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring asmi-52 for management 4-5 asmi-52 management access 1. Telnet allowed ( access allowed ) 2. Web allowed (access allowed) > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-6. Management access menu configur...

  • Page 70

    Chapter 4 configuration installation and operation manual 4-6 configuring asmi-52 for management asmi-52 ver. 2.9 asmi-52 dts configuration dts mode (disable) 1. Dts to cpe (on) 2. Dts ip address ... (0.0.0.0) 3. Dts ip mask ... (0.0.0.0) 4. Rem agent table []> > esc-prev.Menu; !-main menu; &-exit; ...

  • Page 71

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring asmi-52 for management 4-7 asmi-52 vlan encapsulation 1. Host tagging (untagged) 2. Vlan management id [1 – 4094] (1) 3. Vlan priority (0-7) (0) > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-9. Vlan enc...

  • Page 72

    Chapter 4 configuration installation and operation manual 4-8 configuring asmi-52 for management asmi-52 ver. 2.9 asmi-52 rate (9600 kbps) 1. 9600 kbps 2. 19200 kbps 3. 38400 kbps 4. 57600 kbps 5. 115200 kbps > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-11. Control port rate menu 2. Sele...

  • Page 73

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring asmi-52 for management 4-9 configuring the terminal port the port control menu allows you to do the following: • set the port mode (terminal or dial out) • manage the user name and password • enable or disable pop...

  • Page 74

    Chapter 4 configuration installation and operation manual 4-10 configuring asmi-52 for management asmi-52 ver. 2.9 asmi-52 port control mode (terminal) 1. Terminal 2. Dial out > esc-prev.Menu; !-main menu; &-exit; @-scroll figure 4-13. Port control mode menu 2. From the port control mode menu, selec...

  • Page 75

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring asmi-52 for management 4-11 asmi-52 change access 1. User name ...() 2. Password ... 3. Clear user name ... 4. Clear password ... > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-15. Change access menu 2. ...

  • Page 76

    Chapter 4 configuration installation and operation manual 4-12 configuring asmi-52 for management asmi-52 ver. 2.9 • call set up in response to the connect string (at x0) • no echo (at e0) • verbose mode (no codes, e.G., connect string instead of 0) (at v1). 1. From the configuration>system configur...

  • Page 77

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-13 3 to specify the time (in sec) asmi-52 waits for an answer after each dialing attempt. If the called station does not answer within the specified time, asmi-52 disconnects. If additional call at...

  • Page 78

    Chapter 4 configuration installation and operation manual 4-14 configuring for operation asmi-52 ver. 2.9 • configuring the local/remote card • enabling or disabling low speed operation • defining management parameters (ip parameters, system information, etc.) • defining control port parameters • re...

  • Page 79

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-15 asmi-52 master clock (internal) 1. Receive 2. Internal 3. External e1 4. External ir > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-19. Master clock menu configuring local/remote card ...

  • Page 80

    Chapter 4 configuration installation and operation manual 4-16 configuring for operation asmi-52 ver. 2.9 single, or serial dte single may be configured as an e1 or serial dte unit. A multiplexer unit configured as a single unit does not behave as a multiplexer unit. The following applies in remote ...

  • Page 81

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-17 setting the g.704 interface type the g.704 interface type refers to the remote side hardware and is applicable for e1 only. To set the g.704 interface type: 1. From the system configuration menu...

  • Page 82

    Chapter 4 configuration installation and operation manual 4-18 configuring for operation asmi-52 ver. 2.9 asmi-52 shdsl remote port configuration 1. Transmission mode (annex_ab) 2. Power backoff (enable) 3. Asym psd (asym/sym enable) 4. Line prob (adaptive rate) 5. Snext margin (disable snext margin...

  • Page 83

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-19 considered the worst case). This setting is available only if the rate adaptation is enabled (see the line probing configuration below). • disabling the snext margin parameter allows the use of ...

  • Page 84

    Chapter 4 configuration installation and operation manual 4-20 configuring for operation asmi-52 ver. 2.9 2. Select the current margin by typing the number corresponding to the required value, and press . The shdsl remote port menu appears. 3. Select save to save the changes. Configuring the power s...

  • Page 85

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-21 minor alarm (loop attn. Over line a/b) when the selected loop attenuation threshold value is exceeded. To set the loop attenuation threshold: 1. From the configuration>shdsl configuration>shdsl ...

  • Page 86

    Chapter 4 configuration installation and operation manual 4-22 configuring for operation asmi-52 ver. 2.9 configuring the dte interface data rate asmi-52 supports multiple data rates between the range of 64 kbps and 4608 kbps, depending on the clock mode and line/dte interface of the local and remot...

  • Page 87

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-23 4096 kbps multiplexed rate is supported starting from sw version 2.96 and in 4-wire mode only. Configuring the e1 interface the following are commonly used acronyms: • co – central office, where...

  • Page 88

    Chapter 4 configuration installation and operation manual 4-24 configuring for operation asmi-52 ver. 2.9 to access the e1 port configuration menu: • from the configuration>e1 configuration menu, select e1 local port/e1 remote port. The e1 local port/e1 remote port menu appears. Asmi-52 e1 local por...

  • Page 89

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-25 to select e1 framing mode: 1. From the configuration>e1 configuration>e1 local port menu, select framed mode. The framed mode menu appears (see figure 4-28 ). 2. From the framed mode menu, selec...

  • Page 90

    Chapter 4 configuration installation and operation manual 4-26 configuring for operation asmi-52 ver. 2.9 to select resynchronization time: 1. From the configuration>e1 configuration/t1 configuration>e1 local port/t1 local port menu, select sync mode. The sync mode menu appears (see figure 4-29 ). 2...

  • Page 91

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-27 3. Repeat step 2 for all timeslots that you want to assign. Alternatively, you can assign all timeslots to carry data at once by selecting full, or disconnect all timeslots by selecting clear. •...

  • Page 92

    Chapter 4 configuration installation and operation manual 4-28 configuring for operation asmi-52 ver. 2.9 • for e1 + serial dte interfaces, when asmi-52 works opposite megaplex-4100 in 2m mode = (2048 kbps – serial dte data rate) / 64 kbps • for e1 + serial dte interfaces when asmi-52 works with meg...

  • Page 93

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-29 • the unit identical set is permanently set to yes, the parameters are copied to the remote unit. If the frame mode is not g732s: • the unit identical setting can be set to yes or no when the lo...

  • Page 94

    Chapter 4 configuration installation and operation manual 4-30 configuring for operation asmi-52 ver. 2.9 • interface: dsu – dsu interface csu – csu interface • transmit signal mask (dsu mode) – length of a cable in feet between the asmi-52 t1 port connector and the network access point: 0 feet – 0 ...

  • Page 95

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-31 asmi-52 t1 local port configuration 1. Framed mode >(sf) 2. Line code (b8zs/ami) 3. Receive gain (long/short) 4. Interface >(dsu/csu) 5. Transmit signal mask (7.5 db) 6. Fbit configuration (tran...

  • Page 96

    Chapter 4 configuration installation and operation manual 4-32 configuring for operation asmi-52 ver. 2.9 asmi-52 local lan configuration operation mode (bridge) bridging mode (access only) 1. Admin status (up) 2. Bridge table []> 3. Aging timeout(sec)[10 - 1000000] ... (10) 4. Auto negotiation (ena...

  • Page 97

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-33 asmi-52 bridge table mac address port type 0010b340500 lan static 0040e108070 dsl static 00000000000 static > esc-prev. Menu; !-main menu; &-exit; ?-help figure 4-34. Bridge static table, normal...

  • Page 98

    Chapter 4 configuration installation and operation manual 4-34 configuring for operation asmi-52 ver. 2.9 to configure aging timeout: 1. From the configuration>lan configuration>local lan configuration menu, select aging timeout. The lan rate menu appears. 2. Enter a new aging timeout value in secon...

  • Page 99

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 configuring for operation 4-35 asmi-52 user priority 5 (traffic class 0) traffic class 0 = low traffic class 1 traffic class 2 traffic class 3 = high > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 4-37. User priority ...

  • Page 100

    Chapter 4 configuration installation and operation manual 4-36 configuring for operation asmi-52 ver. 2.9 asmi-52 data rate (2304 kbps) 1. 64 kbps 12. 768 kbps 23. 1472 kbps 2. 128 kbps 13. 832 kbps 24. 1536 kbps 3. 192 kbps 14. 896 kbps 25. 1600 kbps 4. 256 kbps 15. 960 kbps 26. 1664 kbps 5. 320 kb...

  • Page 101

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 performing additional tasks 4-37 2. If the autonegotiation is enabled, choose max autoneg capability from the local lan configuration menu. The set capability menu appears. 3. Select the required lan operation mode by choosin...

  • Page 102

    Chapter 4 configuration installation and operation manual 4-38 performing additional tasks asmi-52 ver. 2.9 the monitoring menu appears (see figure 4-39 ). Asmi-52 monitoring 1. Total alarms [] > 2. System monitoring > 3. Physical ports status > 4. Physical ports statistics > 5. Repeater status > 6....

  • Page 103

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 performing additional tasks 4-39 displaying the port status to display the port status information: 1. From the physical port status menu, select port status (main menu > monitoring > physical port status > port status) to di...

  • Page 104

    Chapter 4 configuration installation and operation manual 4-40 performing additional tasks asmi-52 ver. 2.9 to close a virtual terminal • from the monitoring menu of the second asmi-52, select close virtual connection. The main menu of the first asmi-52 is displayed. Displaying the asmi-52 inventory...

  • Page 105

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 performing additional tasks 4-41 asmi-52 inventory 1 index 1001 description rad-local asmi-52_m shdsl modem vendor type contained in 0 class 3 rel pos 0 name shdsl modem hw ver 2.01 sw ver 2.97 ->> > esc-prev. Menu; !-main me...

  • Page 106

    Chapter 4 configuration installation and operation manual 4-42 performing additional tasks asmi-52 ver. 2.9 to enter the user name and password: 1. Type in your user name and press . • you can leave the user name field empty (default), the default password is 1234. 2. Type in your password at the > ...

  • Page 107

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 performing additional tasks 4-43 asmi-52 tftp tftp status (no operation) tftp error (no error) 1. Tftp ip server (172.17.160.103) 2. Tftp file name (201e24.Img) 3. Tftp retry timeout (sec) [0-300] (15) 4. Tftp total timeout (...

  • Page 108

    Chapter 4 configuration installation and operation manual 4-44 performing additional tasks asmi-52 ver. 2.9 to install a new software release via xmodem: 1. From the file utilities>sw & file transfer menu, select xmodem. Asmi-52 responds with the following string: please open xmodem application. For...

  • Page 109

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 performing additional tasks 4-45 asmi-52 auto configuration 1. Xmodem 2. Tftp 3. Command (upload/download full/download part) esc-prev. Menu; !-main menu; &-exit figure 4-46. Software version screen 4. From the file utilities...

  • Page 110

    Chapter 4 configuration installation and operation manual 4-46 performing additional tasks asmi-52 ver. 2.9 currently used by asmi-52, and also details on the passive software kept for backup purposes. To display the software version: • from the file utilities>file system menu, select sw files to di...

  • Page 111

    Installation and operation manual chapter 4 configuration asmi-52 ver. 2.9 performing additional tasks 4-47 resetting asmi-52 asmi-52 supports four types of reset: • reset to the default setting • shdsl interface reset • shdsl repeater line reset • overall reset. Resetting to default settings you ca...

  • Page 112

    Chapter 4 configuration installation and operation manual 4-48 performing additional tasks asmi-52 ver. 2.9 3. Type y to confirm the reset. Asmi-52 resets all configuration parameters, except for the master clock (and ip values), to their default settings and restarts the system. Resetting the asmi-...

  • Page 113: Chapter  5

    Asmi-52 ver. 2.9 monitoring performance 5-1 chapter 5 monitoring and diagnostics this chapter describes the asmi-52 diagnostic functions, which include: • status indications, alarms, power-up self-test • statistics collection • bit error rate test (bert) • diagnostic tests (loopbacks and leds test)....

  • Page 114

    Chapter 5 monitoring and diagnostics installation and operation manual 5-2 monitoring performance asmi-52 ver. 2.9 2. From the physical port statistics menu, select shdsl port performances to display the unit’s sdhsl statistics. The sdhsl port performances menu appears (see figure 5-2 ). Asmi-52 shd...

  • Page 115

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 monitoring performance 5-3 asmi-52 shdsl current day performances local a local b remote a remote b port number (1) (1) (1) (1) 24 hour es (1) (1) (1) (1) 24 hour uas (1401) (1401) (1401) (1401) 24 hour ses (0) (...

  • Page 116

    Chapter 5 monitoring and diagnostics installation and operation manual 5-4 monitoring performance asmi-52 ver. 2.9 asmi-52 shdsl all intervals local/remote performances ... Line a line b int crc losws es ses uas crc losws es ses uas esc-prev. Menu; !-main menu; &-exit; ?-help; @-scroll figure 5-5. S...

  • Page 117

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 monitoring performance 5-5 • for details on enabling the crc-4 function, refer to chapter 4 . • for the details on configuring t1 framing, refer to configuring t1 interface in chapter 4. Displaying the current e1...

  • Page 118

    Chapter 5 monitoring and diagnostics installation and operation manual 5-6 monitoring performance asmi-52 ver. 2.9 asmi-52 e1/t1 current day performance local remote port number (1) no statistics collection esc-prev. Menu; !-main menu; &-exit; @-scroll figure 5-9. E1/t1 current day performances scre...

  • Page 119

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 monitoring performance 5-7 table 5-2. E1 statistics parameters (cont.) display description range current dm number of degraded minutes in which the ber exceeded 1×10 -6 . This value is updated every minute for 15...

  • Page 120

    Chapter 5 monitoring and diagnostics installation and operation manual 5-8 handling events asmi-52 ver. 2.9 5.2 detecting errors power-up self-test asmi-52 performs a hardware self-test upon power-up. The self-test sequence checks the critical circuit functions of the modem. The results of the hardw...

  • Page 121

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 handling events 5-9 2. Press to refresh the display. Asmi-52 total alarms source name num severity status remote 1 psd not connected 8 major on > esc-prev. Menu; !-main menu; &-exit; @-scroll figure 5-11. Total a...

  • Page 122

    Chapter 5 monitoring and diagnostics installation and operation manual 5-10 handling events asmi-52 ver. 2.9 in addition, the system monitoring menu provides access to dts configuration display (rem agent table). For description of table parameters see chapter 4. Displaying the port status 1. Follow...

  • Page 123

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 handling events 5-11 no. Terminal message port description severity 5 rlb from dte dte remote loopback has been activated by a physical connector (units with v.35 dte interface only) warning 6 prop prot fail shds...

  • Page 124

    Chapter 5 monitoring and diagnostics installation and operation manual 5-12 handling events asmi-52 ver. 2.9 no. Terminal message port description severity 28 e1 bpv err exc t1 bpv err exc dte e1 or t1 bipolar violation errors exceed the threshold minor 29 e1 frame slip exc dte e1 frame slips exceed...

  • Page 125

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 handling events 5-13 no. Terminal message port description severity 46 snr margin over network side shdsl signal-to-noise margin at the network side of the repeater has exceeded the alarm threshold. Major (all) 4...

  • Page 126

    Chapter 5 monitoring and diagnostics installation and operation manual 5-14 handling events asmi-52 ver. 2.9 terminal message description crc event line b crc errors are detected on line b sw download fail software download failed buffer overflow more than 100 entries registered in the log file wd r...

  • Page 127

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 handling events 5-15 to clear the log file: 1. From the physical port status menu, select port clear log file (monitoring > physical port status > port clear log file) to clear the log file. A confirmation messag...

  • Page 128

    Chapter 5 monitoring and diagnostics installation and operation manual 5-16 performing diagnostic tests asmi-52 ver. 2.9 5.4 troubleshooting use the chart shown in table 5-6 to identify and remedy problems in unit operation. Table 5-6. Troubleshooting chart fault probable cause remedial action power...

  • Page 129

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 performing diagnostic tests 5-17 the bert, rlb + bert can be set only if there is a connection to the fe unit. The following are the bert test patterns that can be selected: • 2e15-1 • mark • space • alternate be...

  • Page 130

    Chapter 5 monitoring and diagnostics installation and operation manual 5-18 performing diagnostic tests asmi-52 ver. 2.9 asmi-52 bert bert (on/off) bert + rlb (on/off) bert pattern > save bert parameters > esc-prev. Menu ; !–main menu ; &–exit terminal figure 5-15. Bert menu 3. From the bert menu, s...

  • Page 131

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 performing diagnostic tests 5-19 the bert result window is displayed, (see figure 5-18 ) asmi-52 bert results local remote run time (seconds) 2000 sync loss state sync loss sync run time (seconds) 2000 sync loss ...

  • Page 132

    Chapter 5 monitoring and diagnostics installation and operation manual 5-20 performing diagnostic tests asmi-52 ver. 2.9 figure 5-19. Loopback with multiplexer units running the local loopback the local loopback (llb) checks the performance of the local asmi-52 modem, the local dte and the connectio...

  • Page 133

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 performing diagnostic tests 5-21 2. From the diagnostics menu, select: local test to run the llb on the local asmi-52 remote test to run the llb on the remote asmi-52. The local/remote test menu appears (see figu...

  • Page 134

    Chapter 5 monitoring and diagnostics installation and operation manual 5-22 performing diagnostic tests asmi-52 ver. 2.9 running the remote loopback the remote loopback (rlb) checks the performance of both the local and remote asmi-52 modems, and the lines connecting them (see figure 5-23 ). Asmi-52...

  • Page 135

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 performing diagnostic tests 5-23 to activate the remote loopback at the shdsl repeater: 1. From the diagnostics menu, select repeater test (main menu > diagnostics > repeater test). The repeater test menu appears...

  • Page 136

    Chapter 5 monitoring and diagnostics installation and operation manual 5-24 frequently asked questions asmi-52 ver. 2.9 the tst indicator turns off. Running the leds test the user can perform the front-panel led test to verify that the local unit indicators are functioning properly. To run the leds ...

  • Page 137

    Installation and operation manual chapter 5 monitoring and diagnostics asmi-52 ver. 2.9 frequently asked questions 5-25 qhow to provide an external clock when working with x.21 interface? Ain x.21 interface, when working in external clock mode (at the asmi-52), you will need to provide an external c...

  • Page 138

    Chapter 5 monitoring and diagnostics installation and operation manual 5-26 technical support asmi-52 ver. 2.9 athe "prop protocol fail" alarm indicates that the local modem has lost management communication with the remote modem. It is an alarm that normally appears when there are error bits on the...

  • Page 139: Chapter  6

    Chapter 6 software upgrade software upgrade is required to fix product limitations, enable new features, or to make the unit compatible with other devices that are already running the new software version. The information includes the following: • detailed conditions required for the upgrade • any i...

  • Page 140

    Chapter 6 software upgrade installation and operation manual 6.4 prerequisites this section details the asmi-52 software and versions compatible with version 2.9. It also lists the software file names and outlines system requirements needed for the upgrade procedure. Software files version 2.9 relea...

  • Page 141

    Installation and operation manual chapter 6 software upgrade figure 6-1. Downloading a software application file to asmi-52 via tftp use the following procedure to download software release 2.0 to asmi-52 via the file utilities menu. 1. Verify that the asmi52_2.9x.Img file is stored on the pc with t...

  • Page 142

    Chapter 6 software upgrade installation and operation manual asmi-52 host ip host ip address (172.17.161.73) host ip mask (255.255.255.0) host default gateway (172.17.161.1) read community (public) write community (public) trap community (public) > esc-prev. Menu; !-main menu; &-exit; @-scroll figur...

  • Page 143

    Installation and operation manual chapter 6 software upgrade if a failure occurs during downloading or decompression, the new version is erased from the flash and the backup version becomes active. In this case, only one version is left stored in the flash memory. If the active software becomes corr...

  • Page 144

    Chapter 6 software upgrade installation and operation manual resets itself. This causes the new software to be loaded into the modem's ram. Installing a new software release via xmodem notes • • installation of the new software releases via xmodem is not possible over telnet. • to minimize the softw...

  • Page 145

    Installation and operation manual chapter 6 software upgrade two software downloading options are available from the boot menu: • downloading using the xmodem protocol. This is usually performed by downloading from a pc directly connected to the control port of the unit. Figure 6-5. Downloading a so...

  • Page 146

    Chapter 6 software upgrade installation and operation manual rad asmi_52 boot version 1.00 (nov 9 2004) rad boot manager version 7.01 (nov 9 2004) 0 - exit boot-manager 1 - dir 2 - set active software copy 3 - delete software copy 4 - download files or an application by xmodem 5 - format flash 6 - s...

  • Page 147

    Installation and operation manual chapter 6 software upgrade loading ... Decompressing to ram. Processing archive: flash extracting asmi52.Bin .......................................................... .................................................................... Crc ok running ... **********...

  • Page 148

    Chapter 6 software upgrade installation and operation manual 3. Select perform reset to the board to reset asmi-52. The new parameters take effect only after the resetting is completed. ³ to download software from the boot menu using tftp: 1. From the boot menu, select download an application by tft...

  • Page 149: Chapter  7

    Chapter 7 application tutorial this chapter describes how to build a typical application using an lrs-16 and asmi-52 units. Figure 7-1 illustrates a typical application using an asmi-52 unit with lrs-16 on the central site. Figure 7-1. One lrs-16 unit performing backbone data transmission to asmi-52...

  • Page 150

    Chapter 7 application tutorial installation and operation manual installing lrs-16 before starting configuration, install the unit as follows: 1. Connect the lan to the mng-eth port of the lrs-16 device using straight ethernet cable with rj-45 connector. Ethernet copper cable with rj-45 connectors l...

  • Page 151

    Installation and operation manual chapter 7 application tutorial split e1 cable with rj-45 connectors rj-45 shdsl port on asmi-52 rj-45 shdsl port on asmi-52 figure 7-4. Connecting shdsl to asmi-52 4. Connect a supervisory terminal to the control port of the lrs-16 device using straight copper rs-23...

  • Page 152

    Chapter 7 application tutorial installation and operation manual copper cable with db-15 connectors station clock port figure 7-6. Connecting station clk to clock generator 6. Power up the lrs-16 unit. Verify that the ps1 and/or ps2 leds in the front panel are lit. 7. Verify lrs-16 correct startup b...

  • Page 153

    Installation and operation manual chapter 7 application tutorial mode for optimal view of system menus (properties> settings> terminal setup> 132 column mode). Lrs-16 user name: password esc-clear; &-exit 1m/ 1c ³ to enter as a superuser: 1. Enter su for user name. 2. Enter 1234 for password. The ma...

  • Page 154

    Chapter 7 application tutorial installation and operation manual 2. Enter the following parameters (for example): • ip address – 172.17.152.131 • ip mask – 255.255.255.0 • default gateway – 172.17.152.1 3. Press to save the parameters. The changes are saved in the unit. Configuring the network manag...

  • Page 155

    Installation and operation manual chapter 7 application tutorial setting management access ³ to set telnet, snmp, or web access permissions for a user: 1. Select main menu> configuration> system> management> management access. The management access screen appears. Lrs-16 configuration>system>managem...

  • Page 156

    Chapter 7 application tutorial installation and operation manual lrs-16 configuration>system>terminal>baud rate (9600 bps) 1. 9600 bps 2. 19200 bps 3. 38400 bps 4. 57600 bps 5. 115200 bps > esc-previous menu; !-main menu; &-exit 1m/ 1c figure 7-12. Baud rate screen 3. Select the desired baud rate (9...

  • Page 157

    Installation and operation manual chapter 7 application tutorial 3. Set the other parameters required by your system if needed. 4. Press to save the changes. Lrs-16 configuration>physical layer>e1 1. E1 link number[1 - 16] ... (1) 2. Administrative status (up) 3. User name ... (e1-1) 4. Interface ty...

  • Page 158

    Chapter 7 application tutorial installation and operation manual configuring the station clock transmitted data can be clocked either from an internal clock within the lrs-16, or from an external clock via the shdsl or e1 links. ³ to configure the clock source: 1. Navigate to main menu> configuratio...

  • Page 159

    Installation and operation manual chapter 7 application tutorial lrs-16 utilities>file transfer>tftp 1. Server ip address ... (172.17.152.46) 2. Remote file name ... (remote_lrs_16.Cfg) 3. File type (configuration) 4. Command > > esc-previous menu; !-main menu; &-exit 1 m/ 1 c figure 7-17. Tftp scre...

  • Page 160

    Chapter 7 application tutorial installation and operation manual 2. From the main menu, select diagnostics> local tests. The local tests screen appears. Lrs-16 diagnostics>local tests 1. Link number[1 - 16] ... (1) 2. Test type > (disable) 3. Test time out[0 - 4096] ... (0) 4. Bert pattern > (2e-15)...

  • Page 161

    Installation and operation manual chapter 7 application tutorial lrs-16 diagnostics>remote test 1. Link number[1 - 16] ... (1) 2. Test type > (disable) 3. Test time out[0 - 4095] ... (0) > esc-prev.Menu; !-main menu; &-exit 1 m/ 1 c figure 7-20. Remote test screen 3. Select the link (port) number. 4...

  • Page 163

    Installation and operation manual chapter 7 application tutorial the events are layered hierarchically, for example physical layer events/traps for loop attenuation and snr margin are threshold triggered, so that an event/trap is sent only if the threshold was exceeded. Threshold can be configured f...

  • Page 164

    Chapter 7 application tutorial installation and operation manual 7-16 equipment list asmi-52 ver. 2.9.

  • Page 165: Appendix  A

    Appendix a connection data a.1 dte interface connectors v.35, x.21, and rs-530 interface connectors the v.35 interface of the asmi-52 modem terminates in a 34-pin female connector. The x.21 interface terminates in a 15-pin, d-type female connector. The rs-530 interface terminates in a 25-pin, d-type...

  • Page 166

    Appendix a connection data installation and operation manual a-2 dte interface connectors asmi-52 ver. 2.9 signal function v.35 rs-530 x.21 description 34-pin db-25 db-15 pin circuit pin circuit pin circuit (function) data set ready e dsr 107 6 22 cc(a) cc(b) a positive level from asmi-52 when power...

  • Page 167

    Installation and operation manual appendix a connection data e1 and t1 interface connector the balanced e1 and t1 interfaces terminate in rj-45 connector. Table a-2 lists the balanced connector pin assignment. Table a-2. E1/t1 connector pinout pin function 1, 2 transmit (output) 4, 5 receive (input)...

  • Page 168

    Appendix a connection data installation and operation manual a.3 control connector the control terminal interface terminates in a v.24/rs-232 9-pin d-type female connector that can be configured as dce or dte (see the selecting the control port interface section in chapter 4). Table a-6 lists the co...

  • Page 169

    Installation and operation manual appendix a connection data asmi-52 ver. 2.9 alarm relay connector a-5 table a-6. Control connector signal direction control signal interface type dce dte cts out not used dcd out out dsr out out dtr in in ri not used in rts in in when connected and turned on, the te...

  • Page 170

    Appendix a connection data installation and operation manual alarm connector minor-no 1 2 3 4 5 6 major-no major alarm relay minor alarm relay minor-nc major-nc minor-com major-com figure a-2. Alarm pin functions a-6 alarm relay connector asmi-52 ver. 2.9.

  • Page 172

    Publication no. 148-200-04/12 order this publication by catalog no. 803471 international headquarters 24 raoul wallenberg street tel aviv 69719, israel tel. 972-3-6458181 fax 972-3-6498250, 6474436 e-mail market@rad.Com north america headquarters 900 corporate drive mahwah, nj 07430, usa tel. 201-52...