    Installation and operation manual sps-6, sps-12 multiprotocol frad/pad packet switches.

  • Page 3: Notice

    Sps-6, sps-12 multiprotocol frad/pad packet switches installation and operation manual notice this manual contains information that is proprietary to rad data communications ltd. ("rad"). No part of this publication may be reproduced in any form whatsoever without prior written approval by rad data ...

  • Page 4: Limited Warranty

    Limited warranty rad warrants to distributor that the hardware in the sps-6, sps-12 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to distributor. If, during the warranty pe...

  • Page 5: Product Disposal

    Product disposal to facilitate the reuse, recycling and other forms of recovery of waste equipment in protecting the environment, the owner of this rad product is required to refrain from disposing of this product as unsorted municipal waste at the end of its life cycle. Upon termination of the unit...

  • Page 6: Handling Energized Products

    In some cases, the users may insert their own sfp laser transceivers into the product. Users are alerted that rad cannot be held responsible for any damage that may result if non-compliant transceivers are used. In particular, users are warned to use only agency approved products that comply with th...

  • Page 7

    The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16a. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35a. Before connecting the dc supply wires,...

  • Page 8

    Some selv and non-selv circuits use the same connectors. Use caution when connecting cables. Extra caution should be exercised during thunderstorms. When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connections s...

  • Page 9: Fcc-15 User Information

    Fcc-15 user information this equipment has been tested and found to comply with the limits of the class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envir...

  • Page 10: Declaration of Conformity

    Declaration of conformity manufacturer's name: rad data communications ltd. Manufacturer's address: 24 raoul wallenberg st. Tel aviv 69719 israel declares that the product: product name: sps-6, sps-12 conforms to the following standard(s) or other normative document(s): emc : en 55022 (1994) limits ...

  • Page 11: Contents

    Sps-6, sps-12 i contents chapter 1. Introduction 1.1 overview..................................................................................................................... 1-1 1.2 technical specifications............................................................................................

  • Page 12

    Table of contents installation and operation manual ii sps-6, sps-12.

  • Page 13: Chapter 1

    Sps-6, sps-12 overview 1-1 chapter 1 introduction 1.1 overview the sps-6, sps-12 multiprotocol frad/switches provide easy, cost-effective access to a packet switching network. They also provide packet switching capability for both x.25 and frame relay. Sps-6, sps-12 has six or twelve ports, respecti...

  • Page 14

    Chapter 1 introduction installation and operation manual 1-2 technical specifications sps-6, sps-12 1.2 technical specifications synchronous links number of links 6 for sps-6 12 for sps-12 data rate each 3 links aggregate up to 2.15 mbps interface rs-232/v.24, x.21, v.35, v.36/rs-449, or rs-530 (sel...

  • Page 15

    Installation and operation manual chapter 1 introduction sps-6, sps-12 technical specifications 1-3 led indicators power link activity (for each link) sub-channels activity loss of synchronization (for each link) error overflow test power supply supply voltage: 115 or 230 vac (in accordance with ord...

  • Page 16

    Chapter 1 introduction installation and operation manual 1-4 technical specifications sps-6, sps-12.

  • Page 17: Chapter 2

    Sps-6, sps-12 site requirements 2-1 chapter 2 installation and setup 2.1 introduction this chapter provides mechanical and electrical installation procedures for sps-6, sps-12, and basic operating procedures. Sps-6, sps-12 is delivered completely assembled. It is designed for installation as a deskt...

  • Page 18

    Chapter 2 installation and setup installation and operation manual 2-2 hardware configuration information sps-6, sps-12 main links connections the sps-6 has six main links connectors and the sps-12 has twelve main links connectors. The main links connector depends on the ordered interface: • rs-232/...

  • Page 19

    Installation and operation manual chapter 2 installation and setup sps-6, sps-12 hardware configuration information 2-3 figure 2-1. Sps-12 internal boards internal jumpers access inside the equipment is only permitted to qualified and authorized service personnel. To avoid the danger of electrical s...

  • Page 20

    Chapter 2 installation and setup installation and operation manual 2-4 hardware configuration information sps-6, sps-12 ir-eth jumper, j13 when set to nor, this jumper enables the ir-eth interface at links 7. Ir-eth jumper, jp44 when set to nor, this jumper enables the ireth interface at links 1. Fi...

  • Page 21

    Installation and operation manual chapter 2 installation and setup sps-6, sps-12 hardware configuration information 2-5 the v.24/v.35/rs-530/x.21 interface board can be configured as dce or dte by changing the main jumper. The main jumper consists of multiple jumpers that must be changed together. E...

  • Page 22

    Chapter 2 installation and setup installation and operation manual 2-6 installation in 19" racks sps-6, sps-12 2.5 installation in 19" racks sps-6, sps-12 can be installed in a 19" rack. Unit height corresponds to 1u (1.75"). The width of the unit is slightly less than the available mounting width. ...

  • Page 23

    Installation and operation manual chapter 2 installation and setup sps-6, sps-12 cable connections 2-7 figure 2-4. Installation of sps-12 in 19" rack 2.6 cable connections general sps-6 has six connectors and sps-12 has twelve connectors located on the rear panel that serve as the synchronous links....

  • Page 24

    Chapter 2 installation and setup installation and operation manual 2-8 cable connections sps-6, sps-12 synchronous links connection the sps-6, sps-12 synchronous links interfaces are configured as dte interfaces, intended for connection to synchronous modems that are capable of providing the clock s...

  • Page 25: Chapter 3

    Sps-6, sps-12 controls, indicators and connectors 3-1 chapter 3 operation 3.1 general sps-6, sps-12 supports a wide range of applications, such as: • backbone for a low-cost private synchronous network with optional connection to the public network • expansion of the number of asynchronous channels,...

  • Page 26

    Chapter 3 operation installation and operation manual 3-2 controls, indicators and connectors sps-6, sps-12 table 3-1. Controls, indicators and connectors item control, indicator or connector function 1 pwr indicator lights when the unit is powered. 2 main links activity indicators indicators, one f...

  • Page 27

    Installation and operation manual chapter 3 operation sps-6, sps-12 operating instructions 3-3 rear panel controls and connectors table 3-2 lists the functions of the sps-12 rear panel controls and connectors. The numbers under the heading “item” refer to the identification numbers in figure 3-2 . T...

  • Page 28

    Chapter 3 operation installation and operation manual 3-4 upgrading the software sps-6, sps-12 normal operation during normal operation, the pwr, sync and main indicators light continuously and the test, ovf and err indicators remain off. Channel activity indicators flash according to the traffic lo...

  • Page 29

    Installation and operation manual chapter 3 operation sps-6, sps-12 upgrading the software 3-5 3. In the system control menu, select option 12. The following screen appears: this action will enable you to download a new software version after reset in order to do so, please connect a terminal config...

  • Page 30

    Chapter 3 operation installation and operation manual 3-6 what to do in case of malfunction sps-6, sps-12 3.5 what to do in case of malfunction preliminary checks in case a problem occurs, the following actions will help you return the sps-6/sps- 12 to normal operation. • check if the sps-6/sps-12 i...

  • Page 31: Appendix A

    Sps-6, sps-12 interface connectors a-1 appendix a connector pinouts this appendix provides information needed for the sps-6, sps-12 interface connections. The information presented in this appendix includes a description of the control connector, connector pin functions and where applicable – the re...

  • Page 32

    Appendix a connector pinouts installation and operation manual a-2 interface connectors sps-6, sps-12 v.35 port pinouts v.36 port pinouts.

  • Page 33

    Installation and operation manual appendix a connector pinouts sps-6, sps-12 control connector a-3 rs-530 port pinouts a.2 control connector the control connector of sps-6, sps-12 is an rj-45 8-pin female connector with a serial rs-232 dce interface, intended for connection to an ascii-based termina...

  • Page 34

    Appendix a connector pinouts installation and operation manual a-4 control connector sps-6, sps-12 figure a-1. Wiring rj-45 to db-9 adapter cable (cbl-rj45/db9/f/str).

  • Page 35: Customer Response Form

    24 raoul wallenberg st., tel aviv 69719, israel tel: +972-3-6458181, fax: +972-3-6483331, +972-3-6498250 e-mail: , web site: customer response form rad data communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us a...

  • Page 37: Error Report

    Error report type of error(s) incompatibility with product or problem(s): difficulty in understanding text regulatory information (safety, compliance, warnings, etc.) difficulty in finding needed information missing information illogical flow of information style (spelling, grammar, references, etc....

  • Page 40

    Publication no. 216-201-10/06 www.Rad.Com international headquarters: 24 raoul wallenberg street, tel aviv 69719, israel, tel: 972-3-6458181 fax: 972-3-6498250, 972-3-6474436, email: market@rad.Com north america headquarters: 900 corporate drive, mahwah, n.J. 07430, tel: (201) 529-1100 toll free: 1-...