RAD Data Communications Vmux-2100 Installation And Operation Manual - General Safety Instructions

Manual is about: Voice Trunking Gateway

Summary of Vmux-2100

  • Page 1

    Vmux-2100 voice trunking gateway version 4.0 instal lation and operati on manual the access company.

  • Page 3: Vmux-2100

    Vmux-2100 voice trunking gateway version 4.0 installation and operation manual notice this manual contains information that is proprietary to rad data communications ltd. ("rad"). No part of this publication may be reproduced in any form whatsoever without prior written approval by rad data communic...

  • Page 4: Limited Warranty

    Limited warranty rad warrants to distributor that the hardware in the vmux-2100 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to distributor. If, during the warranty period...

  • Page 5: General Safety Instructions

    General safety instructions the following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety symbols this symbol may appear on the equipment or in the text. It in...

  • Page 6: Handling Energized Products

    Handling energized products general safety practices do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the off position or a fuse is blown. For dc-powered products, altho...

  • Page 7

    Before connecting the dc supply wires, ensure that power is removed from the dc circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the off position. When connecting the dc supply wires, first connect the ground wire to the corresponding terminal, then...

  • Page 8

    There are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors. To reduce the risk of fire, use only no. 26 awg or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunication...

  • Page 9: Fcc-15 User Information

    Fcc-15 user information this equipment has been tested and found to comply with the limits of the class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envir...

  • Page 10: Declaration of Conformity

    Declaration of conformity manufacturer's name: rad data communications ltd. Manufacturer's address: 24 raoul wallenberg st., tel aviv 69719, israel declares that the product: product name: vmux-2100 conforms to the following standard(s) or other normative document(s): emc: en 55022:1994 limits and m...

  • Page 11: Quick Start Guide

    Vmux-2100 ver. 4.0 installing vmux-2100 1 quick start guide installation of vmux-2100 should be carried out only by an experienced technician. If you are familiar with vmux-2100, use this guide to prepare the unit for operation. 1. Installing vmux-2100 connecting the interfaces refer to appendix a f...

  • Page 12

    Quick start guide installation and operation manual 2 configuring vmux-2100 vmux-2100 ver. 4.0 the unit has no power switch. Operation starts when the power is applied to the rear panel power connector. 2. Configuring vmux-2100 configure vmux-2100 to the desired operation mode via an ascii terminal ...

  • Page 13

    Installation and operation manual quick start guide vmux-2100 ver. 4.0 configuring vmux-2100 3 configuring voice card parameters configuring the voice card parameters: 1. From the appropriate group menu, assign an ip address to the group (main menu > configuration > card > slot n > group n). 2. From...

  • Page 14

    Quick start guide installation and operation manual 4 configuring vmux-2100 vmux-2100 ver. 4.0 configuring vmux-2100 for operation with ccs signaling configuration of the vmux-2100 units operating with the ccs signaling is similar to the configuration for operation with the cas signaling, except for...

  • Page 15: Contents

    Vmux-2100 ver. 4.0 i contents chapter 1. Introduction 1.1 overview.................................................................................................................... 1-1 product options.....................................................................................................

  • Page 16

    Table of contents installation and operation manual ii vmux-2100 ver. 4.0 connecting to e1/t1 voice ports ............................................................................. 2-4 connecting to main link............................................................................................

  • Page 17

    Installation and operation manual table of contents vmux-2100 ver. 4.0 iii configuring the t1 main link port..................................................................... 4-26 configuring the voice module................................................................................ 4-29 con...

  • Page 18

    Table of contents installation and operation manual iv vmux-2100 ver. 4.0 sanity error and warning list ................................................................................ 6-26 6.3 handling alarms .............................................................................................

  • Page 19: Chapter 1

    Vmux-2100 ver. 4.0 overview 1-1 chapter 1 introduction 1.1 overview vmux-2100 is a modular voice trunking gateway that enables up to 16 e1 or t1 circuits to be extended over a single e1, t1, serial or ip link. Vmux-2100 implements g.723.1, g.729 a, g.711 and tdmoip or aal2ompls multiplexing algorith...

  • Page 20

    Chapter 1 introduction installation and operation manual 1-2 overview vmux-2100 ver. 4.0 vmux-2100 main link also supports unbalanced e1 interfaces. This requires the use of an external rj-45-to-bnc interface adapter, cbl-rj45/2bnc/e1, as well as setting the internal jumpers (see setting the interna...

  • Page 21

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 overview 1-3 central site pstn e1/t1 trunks ip network site a vmux-2100 e1/t1 trunks pbx site a vmux-2100 e1/t1 trunks pbx site a vmux-2100 e1/t1 trunks pbx site a site b site c figure 1-3. Transmitting compressed voice in p...

  • Page 22

    Chapter 1 introduction installation and operation manual 1-4 overview vmux-2100 ver. 4.0 features main link ports e1 main link balanced redundant e1 main link ports use hdb3 coding and comply with g.703, g.704, g.706, g.732 and g.823 standards. The e1 framers support pass-through g.732n framing with...

  • Page 23

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 overview 1-5 when a lan or tdm network fails, vmux-2100 supports automatic switching from the failed network to the alternate network. This backup feature works only between the non-channelized tdm ports on the main module a...

  • Page 24

    Chapter 1 introduction installation and operation manual 1-6 overview vmux-2100 ver. 4.0 aal2ompls multiplexing when using non-ip based ethernet networks, the aal2ompls format can be used instead of tdmoip. The aal2ompls header is smaller than the tdmoip header, saving about 5% in bandwidth (dependi...

  • Page 25

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 overview 1-7 • built-in bandwidth control - the built-in bandwidth control mechanism works on the same principle as the q.50 protocol, without using the protocol. At times when bandwidth is limited, some voice packets are di...

  • Page 26

    Chapter 1 introduction installation and operation manual 1-8 overview vmux-2100 ver. 4.0 diagnostics vmux-2100 supports local (internal) and remote (external) loopback activation on e1/t1 links. You can also perform tone injection towards the local pbx. In addition, a ping utility is included to con...

  • Page 27

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 physical description 1-9 management sessions can be limited to a predefined list of remote hosts (defined by their ip addresses). Power vmux-2100 can be ordered with one or two hot-swappable power supplies, supporting load s...

  • Page 28

    Chapter 1 introduction installation and operation manual 1-10 physical description vmux-2100 ver. 4.0 vmux 2100 ps1 ps2 1 loc rem 2 3 4 1 loc rem 2 3 4 vca-4e1 1 loc rem power power 2 3 4 4 2 3 1 4e1 1 loc rem 2 3 4 vca-4e1 loc rem a eth/e1 control eth act link tst alm e1 b voice modules channelized...

  • Page 29

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 physical description 1-11 control port basic main module configuration rj-45 ethernet port e1 main module configuration t1 main module configuration serial main module configuration rj-45 e1 ports 50-pin scsi port eth contro...

  • Page 30

    Chapter 1 introduction installation and operation manual 1-12 functional description vmux-2100 ver. 4.0 1.3 functional description figure 1-8 shows a block diagram of vmux-2100. Ethernet main link optional e1/t1/serial main link control port host main module module group 1 group 1 group 2 group 2 vo...

  • Page 31

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 functional description 1-13 serial main link when using the serial main link, vmux-2100 adds hdlc flags to the ethernet frames and transmits them over a tdm network. The serial main link interface of vmux-2100 is fully redun...

  • Page 32

    Chapter 1 introduction installation and operation manual 1-14 functional description vmux-2100 ver. 4.0 signaling signaling information is processed according to signaling mode: cas for e1, robbed bit mf for t1, or ccs for e1 and t1. • cas/robbed bit mf – the signaling data is processed by a separat...

  • Page 33

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 functional description 1-15 • multiple hdlc channels – vmux-2100 supports up to four independent hdlc data streams per e1/t1. Each data stream may occupy one or more consecutive timeslots. • ss7 channels – vmux-2100 supports...

  • Page 34

    Chapter 1 introduction installation and operation manual 1-16 functional description vmux-2100 ver. 4.0 the vmux-2100 continues filling the tdmoip frame until one of the conditions defined by the above parameters is met. Ethernet frame at a later stage, the tdmoip frame becomes part of the standard ...

  • Page 35

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 functional description 1-17 table 1-1. Ethernet frame fields layer field length [bytes] field note 7 preamble 1 sfd 6 destination mac address mac layer 6 source mac address llc layer 2 type ieee 802.1d&q vlan tagging (additi...

  • Page 36

    Chapter 1 introduction installation and operation manual 1-18 functional description vmux-2100 ver. 4.0 ethernet frame when using aal2ompls format the aal2ompls format may be used when using non-ip based ethernet networks. The aal2ompls header is smaller than the ip header, which typically yields a ...

  • Page 37

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 functional description 1-19 channelized e1/t1 main link modules the channelized e1/t1 main link module provides for channelized (bridged) tdm connections between the vmux-2100 and the e1/t1 network. Each module supports up t...

  • Page 38

    Chapter 1 introduction installation and operation manual 1-20 functional description vmux-2100 ver. 4.0 bandwidth utilization when using tdmoip by using tdmoip multiplexing and the voice activity detection, vmux-2100 supports a higher number of voice channels over tdm than is possible by utilizing c...

  • Page 39

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 technical specifications 1-21 1.4 technical specifications main module ethernet main link standards ieee 802.3, 802.3u, ethernet 802.1d&q data rate 10 or 100 mbps, half duplex or full duplex, autonegotiation support statisti...

  • Page 40

    Chapter 1 introduction installation and operation manual 1-22 technical specifications vmux-2100 ver. 4.0 t1 main link number of links two (one active, other backup) data rate 1.544 mbps standards ansi t1.403, at&t tr-62411, itu-t rec. G.703 line code ami, b8zs framing sf, esf, transparent timing in...

  • Page 41

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 technical specifications 1-23 voice modules e1 voice ports ports per module two or four data rate 2.048 mbps per port standards itu-t rec. G.703, g.704, g.706, g.732, g.823 framing g.732s and g.732n with or without crc-4, in...

  • Page 42

    Chapter 1 introduction installation and operation manual 1-24 technical specifications vmux-2100 ver. 4.0 voice processing compression algorithms g.723.1 (5.3 or 6.4 kbps), g.729 a (8 kbps), g.711 (a-law/μ-law) silence suppression g.723.1a, g.729b echo cancellation 32 ms per channel as per g.168 fax...

  • Page 43

    Installation and operation manual chapter 1 introduction vmux-2100 ver. 4.0 technical specifications 1-25 receive signal level 0 to -36 db with csu 0 to -30 db without csu transmit signal level 0, -7.5, -15, or -22.5 db with csu ±2.7v (±10%) at 0–655 ft without csu jitter performance per at&t tr-624...

  • Page 44

    Chapter 1 introduction installation and operation manual 1-26 technical specifications vmux-2100 ver. 4.0 diagnostics tests local and remote loopbacks, tone injection towards the local pbx, ping utility statistics collection main link module: • cpu utilization • ethernet link (as per rfc 3638) • tdm...

  • Page 45: Chapter 2

    Vmux-2100 ver. 4.0 site requirements and prerequisites 2-1 chapter 2 installation and setup this chapter describes installation and setup procedures for the vmux-2100 device. 2.1 introduction after installing the unit: • refer to chapter 3 for the operating instructions. • refer to chapter 4 for the...

  • Page 46

    Chapter 2 installation and setup installation and operation manual 2-2 setting the internal jumpers and switches vmux-2100 ver. 4.0 2.3 package contents the vmux-2100 package includes the following items: • one vmux-2100 unit • vmux-2100 installation and operation manual/cd • cbl-rj45/2bnc/e1, rj-45...

  • Page 47

    Installation and operation manual chapter 2 installation and setup vmux-2100 ver. 4.0 setting the internal jumpers and switches 2-3 setting the main link e1 internal jumpers when using the e1 main link, set the e1 main link board internal jumpers to match the e1 connection type: balanced or unbalanc...

  • Page 48

    Chapter 2 installation and setup installation and operation manual 2-4 connecting to interfaces vmux-2100 ver. 4.0 2.6 mounting the unit vmux-2100 is designed for installation as a desktop or wall-mounted unit. It can also be mounted in a 19" rack. • for rack mounting instructions, refer to the rm-3...

  • Page 49

    Installation and operation manual chapter 2 installation and setup vmux-2100 ver. 4.0 connecting to interfaces 2-5 connecting to main link the vmux-2100 ethernet main link interface terminates in an 8-pin rj-45 connector. Appendix a specifies the pinout of the ethernet connector. The ethernet main l...

  • Page 50

    Chapter 2 installation and setup installation and operation manual 2-6 connecting to power vmux-2100 ver. 4.0 connecting to an ascii terminal the vmux-2100 control port terminates in a 9-pin d-type female interface connector. Appendix a specifies the pinout of the control port connector. To connect ...

  • Page 51

    Installation and operation manual chapter 2 installation and setup vmux-2100 ver. 4.0 connecting to power 2-7 connecting to ac power ac power is supplied to vmux-2100 through a standard 3-prong plug with an integral fuse holder (see figure 2-2 ). Ac power should be supplied through the 5 ft (1.5m) s...

  • Page 52

    Chapter 2 installation and setup installation and operation manual 2-8 connecting to power vmux-2100 ver. 4.0

  • Page 53: Chapter 3

    Vmux-2100 ver. 4.0 indicators 3-1 chapter 3 operation this chapter provides the following information for vmux-2100: • vmux-2100 front-panel indicators • operating procedures (turn-on, front-panel indications, performance monitoring, and turn-off). Installation procedures given in chapter 2 must be ...

  • Page 54

    Chapter 3 operation installation and operation manual 3-2 indicators vmux-2100 ver. 4.0 table 3-1. Vmux-2100 leds name function location tst (yellow) on – a test is active flashes – connection loss is detected on the tdm uplink (only if the tdm line check feature is enabled) front panel and main lin...

  • Page 55

    Installation and operation manual chapter 3 operation vmux-2100 ver. 4.0 default settings 3-3 3.3 default settings vmux-2100 is managed by an ascii terminal or pc running a terminal emulation program via menu-driven embedded software. Table 3-3 lists the default settings of the vmux-2100 configurati...

  • Page 56

    Chapter 3 operation installation and operation manual 3-4 default settings vmux-2100 ver. 4.0 table 3-3. Vmux-2100 default settings (cont.) parameter default value control port set baud rate (bps) 9600 timeout (minutes) 3 dial-in modem disable alarm operations set alarm led severity event hub main b...

  • Page 57

    Installation and operation manual chapter 3 operation vmux-2100 ver. 4.0 default settings 3-5 table 3-3. Vmux-2100 default settings (cont.) parameter default value connect no clock mode dte speed (n*64) 1 control signals (only when interface type is v35 and clock mode is dte) ignore hdlc mode transp...

  • Page 58

    Chapter 3 operation installation and operation manual 3-6 default settings vmux-2100 ver. 4.0 table 3-3. Vmux-2100 default settings (cont.) parameter default value caller id tx delay (msec) (available only if coder/rate is g.729a/8) 400 msec volume 0 db modem (for all modems except relay, which will...

  • Page 59

    Installation and operation manual chapter 3 operation vmux-2100 ver. 4.0 default settings 3-7 table 3-3. Vmux-2100 default settings (cont.) parameter default value q.50 bits pair (only if q.50 protocol is not disabled) a & b profile (only when frame type is g732s or g732s-crc) 1 external t1 paramete...

  • Page 60

    Chapter 3 operation installation and operation manual 3-8 configuration and management alternatives vmux-2100 ver. 4.0 table 3-3. Vmux-2100 default settings (cont.) parameter default value channelized main link module e1 parameters internal switching (only when main link is serial or e1/t1) enable c...

  • Page 61

    Installation and operation manual chapter 3 operation vmux-2100 ver. 4.0 configuration and management alternatives 3-9 3.4 configuration and management alternatives vmux-2100 can be managed using different ports and applications: • local out-of-band management via an ascii terminal connected to rs-2...

  • Page 62

    Chapter 3 operation installation and operation manual 3-10 configuration and management alternatives vmux-2100 ver. 4.0 levels of security vmux-2100 supports a four-level security and user authentication system: • administrator – allowed to configure all the parameters of vmux-2100. • operator – all...

  • Page 63

    Installation and operation manual chapter 3 operation vmux-2100 ver. 4.0 configuration and management alternatives 3-11 login to prevent unauthorized modification of the operating parameters, vmux-2100 supports a four-level security and user authentication system as described in chapter 1 . Vmux-210...

  • Page 64

    Chapter 3 operation installation and operation manual 3-12 configuration and management alternatives vmux-2100 ver. 4.0 navigating the management menus this section provides a general description of the conventions for navigating the software menus accessible from either the local console or via tel...

  • Page 65

    Installation and operation manual chapter 3 operation vmux-2100 ver. 4.0 turning off the unit 3-13 using terminal hot keys terminal hot keys are provided per screen to enhance the functionality that is required of that screen. The available hot keys are listed in the lower part of each screen. The f...

  • Page 66

    Chapter 3 operation installation and operation manual 3-14 turning off the unit vmux-2100 ver. 4.0

  • Page 67: Chapter 4

    Vmux-2100 ver. 4.0 configuring vmux-2100 for management 4-1 chapter 4 configuration the configuration of vmux-2100 is performed via menu-driven embedded software, using a standard ascii terminal or a pc running a terminal emulation application connected to the rear panel control port. Alternatively,...

  • Page 68

    Chapter 4 configuration installation and operation manual 4-2 configuring vmux-2100 for management vmux-2100 ver. 4.0 system 1. Management 2. Control port 3. Date & time update 4. Factory default 5. Show partition information 6. Set the active application 7. Reset card 8. Alarm operations> @ - db up...

  • Page 69

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for management 4-3 the host ip menu appears (see figure 4-4 ). Host ip 1. Set host ip address ... (170.185.190.15) 2. Set subnet mask ... (255.255.255.0) 3. Set default gateway ... (170.185.190.1) 4. R...

  • Page 71

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for management 4-5 telnet 1. Disable 2. Enable 3. Enable managers only > please select item @ - db update; # - db undo esc-prev.Menu; !-main menu; &-exit figure 4-6. Telnet menu 2. From the telnet menu...

  • Page 72

    Chapter 4 configuration installation and operation manual 4-6 configuring vmux-2100 for operation vmux-2100 ver. 4.0 configuring the timeout the timeout specifies a time interval after which vmux-2100 automatically disconnects from the supervisory terminal if no input from the user is detected. The ...

  • Page 73

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-7 • set parameters for the main module tdm uplink bandwidth control • set parameters for the serial port running the ascii terminal • set date and time to the internal time base • reset...

  • Page 74

    Chapter 4 configuration installation and operation manual 4-8 configuring vmux-2100 for operation vmux-2100 ver. 4.0 signaling configuration 1. Signaling profile configuration 2. Ss7 keep-alive suppression rate (0% - no suppression / not ss7) @ - db update; # - db undo esc-prev.Menu; !-main menu; &-...

  • Page 75

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-9 signaling table configuration a bit b bit c bit d bit abcd bits a b c d idle signal 1 0 1 1 oos signal 1 0 1 1 1. 0 8. Not c 2. 1 9. D 3. A 10. Not d 4. Not a 5. B 6. Not b 7. C @ - d...

  • Page 76

    Chapter 4 configuration installation and operation manual 4-10 configuring vmux-2100 for operation vmux-2100 ver. 4.0 configuring keep-alive suppression rate when vmux-2100 with ccs signaling is connected to the pbxs operating with the ss7 signaling, the pbxs use one or more timeslots to transmit si...

  • Page 77

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-11 ss7 keep-alive suppression rate (0% - no suppression / not ss7) 1. 0% - no suppression / not ss7 2. 10% 3. 20% 4. 30% 5. 40% 6. 50% 7. 60% 8. 70% 9. 80% 10. 90% > please select item ...

  • Page 78

    Chapter 4 configuration installation and operation manual 4-12 configuring vmux-2100 for operation vmux-2100 ver. 4.0 to configure link backup: 1. From the management menu ( figure 4-3 ), choose backup configuration. The backup configuration menu appears displaying only the backup parameter. 2. Choo...

  • Page 79

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-13 the primary link is the link that is normally active. Vmux-2100 monitors the primary link and, should it fail, directs voice traffic to the secondary network link. Should the seconda...

  • Page 80

    Chapter 4 configuration installation and operation manual 4-14 configuring vmux-2100 for operation vmux-2100 ver. 4.0 to restrict the type of lan information that is passed over tdm: 1. From the management menu ( figure 4-3 ), choose inhibit lan. The inhibit lan menu appears (see figure 4-15 ). Inhi...

  • Page 81

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-15 management 1. Host ip 2. Manager list 3. Host mux name... (.190.15) 4. User administration 5. Signaling configuration 6. Backup configuration 7. Inhibit lan> (enable lan) 8. Tdm upli...

  • Page 82

    Chapter 4 configuration installation and operation manual 4-16 configuring vmux-2100 for operation vmux-2100 ver. 4.0 for the tdm line check to function, the vmux-2100 on the opposite side must also have the tdm line check feature enabled. To enable or disable the tdm line check: • from the manageme...

  • Page 83

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-17 the discard voice packets threshold level must always be higher than the q.50 stop new calls threshold level. 4. Set the block new modem vbd calls threshold — this object indicates t...

  • Page 84

    Chapter 4 configuration installation and operation manual 4-18 configuring vmux-2100 for operation vmux-2100 ver. 4.0 vca-4e1 – four e1 ports vca-2t1 – two t1 ports vca-4t1 – four t1 ports io-ml-2e1 – channelized main link module with two e1 ports io-ml-4e1 – channelized main link module with four e...

  • Page 85

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-19 set backup bundles for port 1’s bundles (if necessary) assign timeslots to the configured bundles. Configuring the main module the main link module of vmux-2100 may include the follo...

  • Page 86

    Chapter 4 configuration installation and operation manual 4-20 configuring vmux-2100 for operation vmux-2100 ver. 4.0 the lan parameters menu appears (see figure 4-22 ). Lan parameters 1. Set auto negotiation (disable) 2. Set default type > (100baset full duplex) @ - db update; # - db undo esc-prev....

  • Page 87

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-21 main board 1. Lan parameters 2. Serial parameters > please select item @ - db update; # - db undo esc-prev.Menu; !-main menu; &-exit figure 4-23. Main board menu for the m-ipserial c...

  • Page 88

    Chapter 4 configuration installation and operation manual 4-22 configuring vmux-2100 for operation vmux-2100 ver. 4.0 rs232 (v.28) rs449 (v.36) rs530 (eia530) rs530a (eia530a). All interfaces require the use of an adapter cable. For more information, see appendix a . 6. Choose connect. The connect m...

  • Page 89

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-23 e1 parameters 1. Main link 1 2. Main link 2 3. Time slot assignment @ - db update; # - db undo esc-prev.Menu; !-main menu; &-exit figure 4-26. E1 parameters menu 2. From the e1 param...

  • Page 90

    Chapter 4 configuration installation and operation manual 4-24 configuring vmux-2100 for operation vmux-2100 ver. 4.0 g.732s-crc4 (256s multiframe, 16 frames per multiframe, crc-4 function enabled). Restoration time (time required for the e1 port to return to normal operation after sync loss): 1 sec...

  • Page 91

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-25 time slot table ts# 1 2 3 4 5 6 7 8 9 10 11 12 yes yes yes no no no no no no no no no ts# 13 14 15 16 17 18 19 20 21 22 23 24 no no no no yes no no no no no no no ts# 25 26 27 28 29 ...

  • Page 92

    Chapter 4 configuration installation and operation manual 4-26 configuring vmux-2100 for operation vmux-2100 ver. 4.0 since vmux-2100 uses only one e1 main link at a time, the timeslot mapping is applicable also for the inactive e1 port. Configuring the t1 main link port the procedure for configurin...

  • Page 93

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-27 • tx gain level (csu mode only, relative t1 output transmit level): 0 db (no attenuation) -7.5 db (attenuation of -7.5 db relative to the nominal transmit level) -15 db (attenuation ...

  • Page 94

    Chapter 4 configuration installation and operation manual 4-28 configuring vmux-2100 for operation vmux-2100 ver. 4.0 time slot table ts# 1 2 3 4 5 6 7 8 9 10 11 12 yes yes yes no no no no no no no no no ts# 13 14 15 16 17 18 19 20 21 22 23 24 no no no no yes no no no no no no no 1. No 2. Yes @ - db...

  • Page 95

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-29 configuring the voice module you have to assign an ip address to each e1/t1 group. To assign an ip address to a group: 1. From the card menu (see figure 4-20 ), select the slot to wh...

  • Page 96

    Chapter 4 configuration installation and operation manual 4-30 configuring vmux-2100 for operation vmux-2100 ver. 4.0 the bundles parameters menu appears (see figure 4-39 ). Bundles parameters >slot 1> group 1 1. Display bundles 2. Bundle configuration @ - db update; # - db undo esc-prev.Menu; !-mai...

  • Page 97

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-31 2. From the bundles parameters menu, choose bundle configuration. The bundle configuration menu appears (see figure 4-40 ). Bundle configuration >slot 1> group 1 1. Add bundle [1 – 3...

  • Page 98

    Chapter 4 configuration installation and operation manual 4-32 configuring vmux-2100 for operation vmux-2100 ver. 4.0 no –bundle is not connected function: tdmoip: tdmoip format must be selected for ip-based networks. Tdmoip+ (default): further header optimization that saves 4 bytes per voice packet...

  • Page 99

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-33 signaling tos: the hexadecimal byte to be inserted to the signaling tos field of all the frames of this bundle – all non-media frames will be set with signaling tos (0x00 to 0xfc) me...

  • Page 100

    Chapter 4 configuration installation and operation manual 4-34 configuring vmux-2100 for operation vmux-2100 ver. 4.0 disconnected bundle. This notification allows the attached pbx to stop transmitting over a faulty e1/t1 and switch to a backup link. Since some routers might discard the ping message...

  • Page 101

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-35 voice parameters >slot 1> group 1> bundle 1 1. Coder/rate (kbps)> (g.723.1/6.4) 2. Caller id type 3. Tx delay for caller id 4. Volume (to line)> (0 db) 5. Volume (from line)>(0 db) 6...

  • Page 102

    Chapter 4 configuration installation and operation manual 4-36 configuring vmux-2100 for operation vmux-2100 ver. 4.0 volume (from line) – sets the volume gain transmitted upon entry from line to the dsp: -6 db to 6 db in steps of 1 db -12 db and 12 db (-12 db should not be used) fax/modem parameter...

  • Page 103

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-37 tone frequency - specific tone to be detected and relayed. In each of the options, the dsp will not compress the selected tones in order to enable the pbx to perform the custom tone ...

  • Page 104

    Chapter 4 configuration installation and operation manual 4-38 configuring vmux-2100 for operation vmux-2100 ver. 4.0 cdis/cng detection time (n*10 msec) - the amount of time in which 1100 hz & 2100 hz are detected before switching to modem or fax (relevant only to vca cards) 10…100 (default is 40, ...

  • Page 105

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-39 e1 parameters >slot 1> group 1> external 1 1. Connect > (no) 2. Frame > (g.732s) 3. Interface type> (ltu) 4. Restoration time> (1 second (fast)) 5. Clock source> (lbt (local)) 6. Idl...

  • Page 106

    Chapter 4 configuration installation and operation manual 4-40 configuring vmux-2100 for operation vmux-2100 ver. 4.0 ltu (maximum attenuation of 43 db, relative to the nominal transmit level of 0 db, operates at longer ranges) dsu (maximum attenuation of 12 db, relative to the nominal transmit leve...

  • Page 107

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-41 2. From the slot menu (see figure 4-35 ), choose the group containing the port you want to configure. 3. From the group menu (see figure 4-36 ), choose the external port you want to ...

  • Page 108

    Chapter 4 configuration installation and operation manual 4-42 configuring vmux-2100 for operation vmux-2100 ver. 4.0 frame - t1 framing mode: esf (24 frames per multiframe) sf (d4) (12 frames per multiframe). Interface type: dsu (dsu interface) csu (csu interface) line code - line code and zero sup...

  • Page 109

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-43 robbed bit multi-frame (rbmf) ccs (ss7, isdn-pri). The two e1/t1 ports in a group must be configured with the same signaling mode. If you intend to change e1/t1 signaling, it is reco...

  • Page 110

    Chapter 4 configuration installation and operation manual 4-44 configuring vmux-2100 for operation vmux-2100 ver. 4.0 the distribution of framer time slots menu appears (see figure 4-50 ). Distribution of framer time slots >slot 1> group 1> external 1 1. Display time slots 2. Time slots configuratio...

  • Page 111

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-45 ss7 - timeslot carries ss7 signaling data. If ss7 signaling compression is configured (see configuring signaling profiles), compression is performed on this timeslot range. When this...

  • Page 112

    Chapter 4 configuration installation and operation manual 4-46 configuring vmux-2100 for operation vmux-2100 ver. 4.0 vmux-2100 supports up to eight separate transparent sub-data streams. Set destination transp sub ch id to identify which sub-data stream is being configured on this timeslot range (t...

  • Page 113

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-47 configuring the channelized e1/t1 main link module configuring a channelized e1/t1 main link module (io-ml-2e1, io-ml-4e1, io-ml-2t1, io-ml-4t1) consists of the following: • configur...

  • Page 114

    Chapter 4 configuration installation and operation manual 4-48 configuring vmux-2100 for operation vmux-2100 ver. 4.0 e1 parameters >slot 1> group 1> external 1 1. Connect > (no) 2. Frame > (g.732n) 3. Restoration time> (1 second (fast)) 4. Clock source> (lbt (local)) 5. Interface type> (ltu) 6. Idl...

  • Page 115

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-49 interface type - maximum attenuation of the rx signal that can be compensated for by the port rx path, to obtain ber performance required by the standards: ltu (maximum attenuation o...

  • Page 116

    Chapter 4 configuration installation and operation manual 4-50 configuring vmux-2100 for operation vmux-2100 ver. 4.0 no (t1 link is disabled). Clock mode: lbt (derived from the received t1 signal) internal (received from the vmux-2100 internal oscillator). Frame - t1 framing mode: esf (24 frames pe...

  • Page 117

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-51 the following values are illegal, and are replaced by the software with the appropriate default value: 0x00, 0x08, 0x10, 0x12, 0x21, 0x24, 0x42, 0x49, 0x84, 0x92. Configuring bundles...

  • Page 118

    Chapter 4 configuration installation and operation manual 4-52 configuring vmux-2100 for operation vmux-2100 ver. 4.0 the edit bundle menu appears (see figure 4-58 ). Edit bundle >slot 1> group 1> external 1> bundle 1 1. Enter bundle number > (bundle 1 ) 2. Connect> (no) 3. Function> (data relay) 4....

  • Page 119

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 configuring vmux-2100 for operation 4-53 ts bit mask mode - select between bit mask mode insertion (relevant only for ml-t1 cards): menu (default) user defined auto rate selection - select the rate for the timeslot (relevan...

  • Page 120

    Chapter 4 configuration installation and operation manual 4-54 configuring vmux-2100 for operation vmux-2100 ver. 4.0 bundle number (the number of the bundle to which the specified time slot range is to be assigned). 4. Choose update time slot to save your changes. 5. Check the resulting timeslot co...

  • Page 121

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 additional tasks 4-55 4.3 additional tasks updating the database you must save the selected values by updating the vmux-2100 database. If the database is not updated, vmux-2100 discards all the user settings when it is rese...

  • Page 122

    Chapter 4 configuration installation and operation manual 4-56 additional tasks vmux-2100 ver. 4.0 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!! Attention ! !!!!! !!!!!! ----------- !!!!! !!!!!! !!!!! !!!!!! Db upd failed !!!! Data base was not changed !!!!! !!...

  • Page 123

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 additional tasks 4-57 to undo the changes: 1. Type # and press . Vmux-2100 displays the following confirmation screen. ????????????????????????????????????????????????????????????????????????????? ??????????????????????????...

  • Page 124

    Chapter 4 configuration installation and operation manual 4-58 additional tasks vmux-2100 ver. 4.0 inventory slot number name hw revision sw revision main module main link e1 02.00 04.00a2 slot 1 group 1 2t1 voice 01.00 04.00a2 slot 1 group 2 2t1 voice 01.00 04.00a2 slot 2 group 1 not exist slot 2 g...

  • Page 125

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 additional tasks 4-59 factory defaults 1. Clean bundles db 2. Clean slots db > please select item @ - db update; # - db undo esc-prev.Menu; !-main menu; &-exit figure 4-66. Factory defaults menu 2. Select the desired option...

  • Page 126

    Chapter 4 configuration installation and operation manual 4-60 additional tasks vmux-2100 ver. 4.0 managing the user database an administrator manages the database of the users who are allowed to operate or monitor the vmux-2100 system. This allows the administrator to do the following: • add a new ...

  • Page 127

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 additional tasks 4-61 user names are case-sensitive. 5. Choose enter access level to define the new user access level. 6. Select the desired level (monitor, technician, operator or administrator). The access level of a new ...

  • Page 128

    Chapter 4 configuration installation and operation manual 4-62 additional tasks vmux-2100 ver. 4.0 change user details 1. Enter username (to change) ... () 2. Change password ... 3. Confirm and save password ... 4. Change access level > (x) 5. Confirm and save access level ... @ - db update; # - db ...

  • Page 129

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 additional tasks 4-63 resetting the vmux-2100 modules the vmux-2100 management software allows you to re-initialize a single e1/t1 group of each voice module or the main board cpu. Resetting the main board is equivalent to ...

  • Page 130

    Chapter 4 configuration installation and operation manual 4-64 additional tasks vmux-2100 ver. 4.0 time (hh:mm) ... (16:58) date ... (28/2/2007) 1. Clock source > (ntp) 2. Date format > (european format [dd/mm/yyyy]) 3. Ntp server ip address ... (172.17.150.1) 4. Gmt (+/- xx) > (+2 [jerusalem, kyiv]...

  • Page 131

    Installation and operation manual chapter 4 configuration vmux-2100 ver. 4.0 additional tasks 4-65 table 4-3. Date & time parameters - internal clock source parameter description possible values/reference clock source sets the clock source ntp internal default: ntp time displays the current time val...

  • Page 132

    Chapter 4 configuration installation and operation manual 4-66 additional tasks vmux-2100 ver. 4.0

  • Page 133: Chapter 5

    Vmux-2100 ver. 4.0 configuration sequence 5-1 chapter 5 configuring typical applications this chapter gives detailed instructions for configuring vmux-2100 for a typical application in which two vmux-2100 units operate point-to-point over a tdm network. Figure 5-1 illustrates a typical tdm applicati...

  • Page 134

    Chapter 5 configuring typical applications installation and operation manual 5-2 configuring vmux-2100 for operation with cas vmux-2100 ver. 4.0 • saving the configuration file (cnfg.Dat) of the local unit at the management station. • downloading the configuration file to the remote vmux-2100 and up...

  • Page 135

    Installation and operation manual chapter 5 configuring typical applications vmux-2100 ver. 4.0 configuring vmux-2100 for operation with cas 5-3 8. Display the hub menu and enter the existing main link card (m-ipe1) and the voice card (vca-4e1) into the unit’s database (main menu > configuration > h...

  • Page 136

    Chapter 5 configuring typical applications installation and operation manual 5-4 configuring vmux-2100 for operation with cas vmux-2100 ver. 4.0 packetizing interval – 30 connectivity parameters > connectivity mode – with ping connectivity parameters > connectivity-packet rate – 60 sec connectivity ...

  • Page 137

    Installation and operation manual chapter 5 configuring typical applications vmux-2100 ver. 4.0 completing remote vmux-2100 configuration 5-5 11. Repeat step 5 to step 7 for the external port 2 of group 2, except for the following: assign 4 to the destination port id for the timeslots in step 6. Fig...

  • Page 138

    Chapter 5 configuring typical applications installation and operation manual 5-6 configuring vmux-2100 for operation with ccs vmux-2100 ver. 4.0 4. Display the edit bundle menu, and configure the group 2 bundle 1 destination ip to 172.17.15. 12 (main menu > configuration > card > slot 1 > group 2 > ...

  • Page 139: Chapter 6

    Vmux-2100 ver. 4.0 monitoring performance 6-1 chapter 6 troubleshooting and diagnostics this chapter describes the vmux-2100 troubleshooting and diagnostic functions. 6.1 monitoring performance this section explains how to display performance data collected on the vmux-2100 main link and e1/t1 group...

  • Page 140

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-2 monitoring performance vmux-2100 ver. 4.0 the cards statistics menu appears (see figure 6-2 ). Cards statistics 1. Data statistics 2. Bundles / channelized bundles statistics 3. Voice statistics 4. Voice rx signaling sta...

  • Page 141

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-3 6. From the channel menu, select the desired data type. Channel (ss7-1) 1. Ss7-1 13. Sub-ch-5 2. Ss7-2 14. Sub-ch-6 3. Hdlc-1 15. Sub-ch-7 4. Hdlc-2 16. Sub-ch-8 5. Hdlc-3 6. Hdl...

  • Page 142

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-4 monitoring performance vmux-2100 ver. 4.0 data statistics on slot 1 external 1 data ch :hdlc-1 rx statistics total frames :[ 0 ] total bytes :[ 0 ] 60 sec frames :[ 0 ] 60 sec bytes :[ 0 ] lg err :[ 0 ] no err :[ 0 ] cr ...

  • Page 143

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-5 table 6-1. E1/t1 group data statistics field description rx total frames total number of data packets received rx total bytes total number of data octets of all packets received ...

  • Page 144

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-6 monitoring performance vmux-2100 ver. 4.0 data statistics on slot 1 external 1 data ch :trn rx statistics total frames :[ 1272 ] total bytes :[ 101760 ] 60 sec frames :[ 504 ] 60 sec bytes :[ 40320 ] lg err :[ 0 ] no err...

  • Page 145

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-7 • ip oos – there is no ip connectivity between bundles. The reason for this condition may be an illegal ip address of the destination e1/t1 group, or network problems. Tracking p...

  • Page 146

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-8 monitoring performance vmux-2100 ver. 4.0 to display the bundle statistics: 1. From the cards statistics menu, choose bundles statistics. The bundles statistics menu appears (see figure 6-8 ). Bundles/channelized bundles...

  • Page 147

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-9 statistics on slot: 4, group: 1, bundle: 1, state: disconnect rx statistics total frames :[ 1253 ] total bytes :[ 76130 ] 60 sec frames :[ 0 ] 60 sec bytes :[ 0 ] tx statistics t...

  • Page 148

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-10 monitoring performance vmux-2100 ver. 4.0 channelized hdlc stat on slot 1 group 1 external 1 bundle 1 rx statistics total frames :[ 0 ] total bytes :[ 0 ] 60 sec frames :[ 0 ] 60 sec bytes :[ 0 ] lg err :[ 0 ] no err :[...

  • Page 149

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-11 table 6-3. E1/t1 voice bundle statistics values field description state state of this bundle rx total frames total number of packets received rx total bytes total number of data...

  • Page 150

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-12 monitoring performance vmux-2100 ver. 4.0 table 6-3. E1/t1 voice bundle statistics values (cont.) field description seq num: missing number of packets that packets did not arrive in time according to sequence number (ei...

  • Page 151

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-13 table 6-4. Statistics values for channelized e1/t1 main link module (cont.) field description outgoing bw to line – avg. Current bandwidth transmitted on the line since the last...

  • Page 152

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-14 monitoring performance vmux-2100 ver. 4.0 3. From the voice statistics menu, choose group number, and then enter the desired group number from the displayed list to select the group. 4. From the voice statistics menu, c...

  • Page 153

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-15 table 6-6. Timeslot voice statistics values field description dsp mode • idle – dsp is idle for unconfigured channels, mode should always be idle • voice – dsp is transmitting v...

  • Page 154

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-16 monitoring performance vmux-2100 ver. 4.0 table 6-6. Timeslot voice statistics values (cont.) field description 64k nack number of 64k clear channel requests being rejected by vmux circuit state • oos – q.50 is enabled ...

  • Page 155

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-17 voice rx signaling statistics on slot: 1, port: 1 ts1 :[ 1111 ] ts2 :[ 1111 ] ts3 :[ 0000 ] ts4 :[ 0000 ] ts5 :[ 0000 ] ts6 :[ 1111 ] ts7 :[ 1111 ] ts8 :[ 0000 ] ts9 :[ 0000 ] t...

  • Page 156

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-18 monitoring performance vmux-2100 ver. 4.0 displaying statistics for the main module ports the main module ethernet statistics are not ethernet uplink port statistics, but are the statistics of the switch port connected ...

  • Page 157

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-19 displaying the main module ethernet statistics to display the main module ethernet statistics: 1. From the main module statistics menu, choose ethernet statistics. 2. From the e...

  • Page 158

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-20 monitoring performance vmux-2100 ver. 4.0 table 6-7. Main link ethernet statistics values field description rx total frames total number of packets received rx total bytes total number of data octets of all packets rece...

  • Page 159

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-21 table 6-7. Main link ethernet statistics values (cont.) field description rx collision number of received packets with collision event detected rx late collision number of recei...

  • Page 160

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-22 monitoring performance vmux-2100 ver. 4.0 tdm statistics rx : frames [ 0] bytes [ 0] tx : frames [ 113] bytes [ 6528] rx err : bsy [ 0] glitch [ 0] de[ 0] lg[ 0] no [ 0] ab [ 0] cr[ 0] ov[ 0] tx err : underrun [ 0] glit...

  • Page 161

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 monitoring performance 6-23 table 6-8. Tdm main link statistics values (cont.) field description rx no error number of non-octet aligned packets received rx ab error number of packets received with abort s...

  • Page 162

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-24 monitoring performance vmux-2100 ver. 4.0 displaying the backup links status you can display the following information for the links used by the backup feature: • the current state of the primary link • the current stat...

  • Page 163

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 detecting errors 6-25 6.2 detecting errors configuration errors and mismatches are rendered by the vmux-2100 management software as sanity checks. Their main purpose is to maintain the database validity. V...

  • Page 164

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-26 detecting errors vmux-2100 ver. 4.0 display sanity 1. Error 2. Warning @ - db update; # - db undo esc-prev.Menu; !-main menu; &-exit figure 6-23. Display sanity menu 2. From the display sanity menu, choose error to disp...

  • Page 165

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 detecting errors 6-27 table 6-10. Sanity errors and warnings (cont.) id code display type description 211 card exists in slot warning io card physically exists on the slot but was not configured on the hub...

  • Page 166

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-28 detecting errors vmux-2100 ver. 4.0 table 6-10. Sanity errors and warnings (cont.) id code display type description 514 illegal vlan id error vlan id for a bundle is out of the legal range. 517 bundle frame too small fo...

  • Page 167

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 handling alarms 6-29 6.3 handling alarms this section describes the alarms for vmux-2100. It also describes how to configure the alarm led mode. Vmux-2100 detects fault conditions and initiates alarms and ...

  • Page 168

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-30 handling alarms vmux-2100 ver. 4.0 the status menu appears (see figure 6-25 ). Status 1. Display 2. Clear 3. Display sanity @ - db update; # - db undo esc-prev.Menu; !-main menu; &-exit figure 6-25. Status menu 3. From ...

  • Page 169

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 handling alarms 6-31 to delete alarms from the temporary buffer: • from the display menu, choose display & clear alarms to view and then delete the current alarms. Vmux-2100 displays the current alarms and...

  • Page 170

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-32 handling alarms vmux-2100 ver. 4.0 setting the alarm led severity you can configure the alarm severity level that will cause the alm led to turn on. The following levels are available: • event: the led will turn on when...

  • Page 171

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 handling alarms 6-33 list of vmux-2100 alarms table 6-11 lists the vmux-2100 alarms according to their identification codes. Table 6-11. Vmux-2100 alarms id code terminal message description type+ severity...

  • Page 172

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-34 handling alarms vmux-2100 ver. 4.0 table 6-11. Vmux-2100 alarms (cont.) id code terminal message description type+ severity 48 power supply no.2 was inserted power supply 2 has been inserted to its slot. Event 49 power ...

  • Page 173

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 handling alarms 6-35 table 6-11. Vmux-2100 alarms (cont.) id code terminal message description type+ severity 84 t1/e1 frame slip has occurred frame slip occurred on the e1/t1 port event 87 t1/e1 signal lo...

  • Page 174

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-36 handling alarms vmux-2100 ver. 4.0 table 6-11. Vmux-2100 alarms (cont.) id code terminal message description type+ severity 97 local multiframe alarm local loss of multiframe synchronization at the e1 port recommendatio...

  • Page 175

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 testing vmux-2100 6-37 6.4 testing vmux-2100 this section describes the vmux-2100 diagnostic functions, which include: • tone injection • loopbacks (local and remote) • ping utility • display active tests....

  • Page 176

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-38 testing vmux-2100 vmux-2100 ver. 4.0 diagnostics 1. Inject tone test 2. Local loop test (voice cards only) 3. Remote loop test 4. Display active tests 5. Ping > please select item @ - db update; # - db undo esc-prev.Men...

  • Page 177

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 testing vmux-2100 6-39 8. From the inject tone test menu, choose time out, and then enter the desired tone injection timeout (the period of time after which the tone injection stops automatically): 0 secon...

  • Page 178

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-40 testing vmux-2100 vmux-2100 ver. 4.0 local loop test (voice cards only) 1. Slot> (slot 1) 2. Group number> (group 1) 3. External > (external 1) 4. Time out (seconds, 0=forever) [0 - 60]> (0) 5. Activate > please select ...

  • Page 179

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 testing vmux-2100 6-41 to activate a remote loopback: 1. From the diagnostics menu, choose remote loop test. The remote loop test menu appears (see figure 6-36 ). Remote loop test 1. Slot > (slot 1) 2. Gro...

  • Page 180

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-42 frequently asked questions vmux-2100 ver. 4.0 ping 1. Ip address ... (172.17.172.150) 2. Number of pings [1 - 16]... (10) 3. Activate > please select item @ - db update; # - db undo esc-prev.Menu; !-main menu; &-exit fi...

  • Page 181

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 frequently asked questions 6-43 q: can i use a vmux-2100/e1 voice module opposite a vmux-2100/t1? A: yes. You can establish a connection between one site that uses e1-based voice traffic and another site t...

  • Page 182

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-44 frequently asked questions vmux-2100 ver. 4.0 data is transmitted transparently, but the bandwidth for these calls will be a full ts 64 kbps and not dynamically allocated. When using this option, you will need to use th...

  • Page 183

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 frequently asked questions 6-45 bundle between these two units - an illegal condition resulting in unstable bundle connectivity. In addition, it should be noted that: there is no load sharing mechanism tha...

  • Page 184

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-46 frequently asked questions vmux-2100 ver. 4.0 the vmux-2100 (pbx/switch). The output signal is a very good "imitation" of the original input signal, but it is not represented by exactly the same pcm bytes, hence the res...

  • Page 185

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 frequently asked questions 6-47 by default the mfc relay is disabled. Therefore when the vmux-2100 should support mfc tones, the mfc relay has to be enabled. The mfc relay parameters are under the edit bun...

  • Page 186

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-48 frequently asked questions vmux-2100 ver. 4.0 example: when using g.723.1 compression, the dsp expects to receive a packet every 30 msec. If the delay between the received packets is higher than 30 msec, the dsp will in...

  • Page 187

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 frequently asked questions 6-49 due to software changes and added parameters between the various versions, it is impossible to perform an upload of a cnfg.Dat file between two vmux-2100 units that do not h...

  • Page 188

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-50 frequently asked questions vmux-2100 ver. 4.0 when exceeding the bandwidth, some of the packets are lost, and there will be voice quality degradation. Activating the bandwidth control feature can minimize the impact of ...

  • Page 189

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 frequently asked questions 6-51 option 1 erases only configured bundles of voice and channelized e1/t1 modules. Nothing else is affected, including the tdm ports of these modules and their ip address (in c...

  • Page 190

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-52 frequently asked questions vmux-2100 ver. 4.0 vmux-2100 is a statistical multiplexer, which means that the bandwidth is allocated dynamically between all of the vmux channels when they have traffic that must be transpor...

  • Page 191

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 frequently asked questions 6-53 (because the answer from the ip port was received before the answer from the tdm port) this may cause two problems: a vmux-2100 will use the ip uplink for transmission and t...

  • Page 192

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-54 frequently asked questions vmux-2100 ver. 4.0 a: yes. The voice module terminates the t1 or e1 frame. The payload of the voice channels is compressed by the voice module. The compressed voice data and the signaling info...

  • Page 193

    Installation and operation manual chapter 6 troubleshooting and diagnostics vmux-2100 ver. 4.0 frequently asked questions 6-55 parameter), thus emulating the end of the forward signal earlier than the time it would have taken for this end of signal to arrive via the vmux and transmission delay, caus...

  • Page 194

    Chapter 6 troubleshooting and diagnostics installation and operation manual 6-56 technical support vmux-2100 ver. 4.0 6.6 technical support technical support for vmux-2100 can be obtained from the local distributor from whom it was purchased. For further information, please contact the rad distribut...

  • Page 195: Appendix A

    Vmux-2100 ver. 4.0 e1/t1 ports a-1 appendix a connector pinouts a.1 e1/t1 ports balanced e1/t1 interface connector the balanced e1/t1 interfaces of the main link and voice modules terminate in rj-45 connectors. Figure a-1 illustrates the pin location in an rj-45 connector. Table a-1 lists the e1/t1 ...

  • Page 196

    Appendix a connector pinouts installation and operation manual a-2 ethernet utp interface connector vmux-2100 ver. 4.0 rj-45 bnc female receive (green) transmit (red) 1 2 3 4 5 6 7 8 shielded rj-45 transmit (red bnc) receive (green bnc) rx ring rx tip nc tx ring tx tip nc nc nc . . . . . . Figure a-...

  • Page 197

    Installation and operation manual appendix a connector pinouts vmux-2100 ver. 4.0 cbl-vmux-mm-modem cross cable a-3 a.3 control connector the control terminal interface terminates in a v.24/rs-232 9-pin d-type female dce connector. Table a-3 lists the control connector pin assignments. Table a-3. Co...

  • Page 198

    Appendix a connector pinouts installation and operation manual a-4 serial link connector vmux-2100 ver. 4.0 table a-4. Cbl-vmux-mm-modem cross cable wiring modem connector pin vmux connector pin 2 3 3 2 1 7 7 1 4 6 9 4 5 5 a.5 serial link connector the redundant serial links terminate on a single 50...

  • Page 199

    Installation and operation manual appendix a connector pinouts vmux-2100 ver. 4.0 serial interface adapter cables a-5 table a-5. Serial connector pinout (cont.) pin function pin function 25 fgnd 38 not connected 26 not connected 39 dsr-n 27 not connected 40 dtr-n 28 dsr-n 41 dcd-n 29 dtr-n 42 rts-n ...

  • Page 200

    Appendix a connector pinouts installation and operation manual a-6 serial interface adapter cables vmux-2100 ver. 4.0 the specific adapter cable required depends on the type of interface used by the serial uplink. Table a-6 lists the supported interfaces and the respective rad part number of the req...

  • Page 201

    Installation and operation manual appendix a connector pinouts vmux-2100 ver. 4.0 serial interface adapter cables a-7 table a-7. Adapter cable for rs-530/dce interface (cbl-vm2100/530/dce) (cont.) scsi db25f # 1 db25f # 2 remarks pin #35 pin #24 (rxc-n) pin #11 pin #16 (txd-p) pin #36 pin #3 (txd-n)...

  • Page 202

    Appendix a connector pinouts installation and operation manual a-8 serial interface adapter cables vmux-2100 ver. 4.0 table a-7. Adapter cable for rs-530/dce interface (cbl-vm2100/530/dce) (cont.) scsi db25f # 1 db25f # 2 remarks pin #49 (n.C) not connected pin #50 (n.C) not connected table a-8. Ada...

  • Page 203

    Installation and operation manual appendix a connector pinouts vmux-2100 ver. 4.0 serial interface adapter cables a-9 table a-8. Adapter cable for rs530/dte interface (cbl-vm2100/530/dte) (cont.) scsi db25m # 1 db25m # 2 remarks pin #16 pin #10 (dcd-p) pin #41 pin #8 (dcd-n) pin #17 pin #19 (rts-p) ...

  • Page 204

    Appendix a connector pinouts installation and operation manual a-10 serial interface adapter cables vmux-2100 ver. 4.0 table a-9. Adapter cable for x.21/dce interface (cbl-vm2100/x21/dce) scsi db15f # 1 db15f # 2 remarks pin #1 pin #1 (fgnd) pin #2 pin #8 (gnd) pin #3 (dsr-p) pin #28 (dsr-n) pin #4 ...

  • Page 205

    Installation and operation manual appendix a connector pinouts vmux-2100 ver. 4.0 serial interface adapter cables a-11 table a-9. Adapter cable for x.21/dce interface (cbl-vm2100/x21/dce) (cont.) scsi db15f # 1 db15f # 2 remarks pin #43 pin #3 (cts-n) pin #19 (etxc-p) pin #44 (etxc-n) pin #20 pin #1...

  • Page 206

    Appendix a connector pinouts installation and operation manual a-12 serial interface adapter cables vmux-2100 ver. 4.0 table a-10. Adapter cable for x.21/dte interface (cbl-vm2100/x21/dte) scsi db15m # 1 db15m # 2 remarks pin #1 pin #1 (fgnd) pin #2 pin #8 (gnd) pin #3 (dsr-p) pin #28 (dsr-n) pin #4...

  • Page 207

    Installation and operation manual appendix a connector pinouts vmux-2100 ver. 4.0 serial interface adapter cables a-13 table a-10. Adapter cable for x.21/dte interface (cbl-vm2100/x21/dte) (cont.) scsi db15m # 1 db15m # 2 remarks pin #42 pin #3 (rts-n) pin #18 (cts-p) pin #43 (cts-n) pin #19 (etxc-p...

  • Page 208

    Appendix a connector pinouts installation and operation manual a-14 serial interface adapter cables vmux-2100 ver. 4.0 table a-11. Adapter cable for v.35/dce interface (cbl-vm2100/v35/dce) scsi v.35f # 1 v.35f # 2 remarks pin #1 a (fgnd) pin #2 b (gnd) pin #3 (dsr-p) pin #28 h (dsr-n) pin #4 (dtr-p)...

  • Page 209

    Installation and operation manual appendix a connector pinouts vmux-2100 ver. 4.0 serial interface adapter cables a-15 table a-11. Adapter cable for v.35/dce interface (cbl-vm2100/v35/dce) (cont.) scsi v.35f # 1 v.35f # 2 remarks pin #19 x (etxc-p) pin #44 v (etxc-n) pin #20 aa (txc-p) pin #45 y (tx...

  • Page 210

    Appendix a connector pinouts installation and operation manual a-16 serial interface adapter cables vmux-2100 ver. 4.0 table a-12. Adapter cable for v.35/dte interface (cbl-vm2100/v35/dte) scsi v.35m # 1 v.35m # 2 remarks pin #1 a (fgnd) pin #2 b (gnd) pin #3 (dsr-p) pin #28 h (dsr-n) pin #4 (dtr-p)...

  • Page 211

    Installation and operation manual appendix a connector pinouts vmux-2100 ver. 4.0 serial interface adapter cables a-17 table a-12. Adapter cable for v.35/dte interface (cbl-vm2100/v35/dte) (cont.) scsi v.35m # 1 v.35m # 2 remarks pin #19 w (etxc-p) pin #44 u (etxc-n) pin #20 aa (txc-p) pin #45 y (tx...

  • Page 212

    Appendix a connector pinouts installation and operation manual a-18 serial interface adapter cables vmux-2100 ver. 4.0

  • Page 213: Appendix B

    Vmux-2100 ver. 4.0 booting vmux-2100 b-1 appendix b boot manager b.1 introduction this chapter describes the vmux-2100 boot software and provides instructions for software downloading via xmodem or tftp applications. The vmux-2100 software is stored in the flash memory in two sections: boot and file...

  • Page 214

    Appendix b boot manager installation and operation manual b-2 booting vmux-2100 vmux-2100 ver. 4.0 accessing the file system the file system menu is an option that allows you to perform basic file transfer operations. These operations are all optional. When working with the file system menu, configu...

  • Page 215

    Installation and operation manual appendix b boot manager vmux-2100 ver. 4.0 downloading the application and configuration software b-3 b.3 downloading the application and configuration software new application software releases are distributed as *.Img files, which are downloaded to vmux-2100 using...

  • Page 216

    Appendix b boot manager installation and operation manual b-4 downloading the application and configuration software vmux-2100 ver. 4.0 downloading application files via tftp the application software is downloaded when vmux-2100 has been already completed the boot-up procedure and the management sof...

  • Page 217: Appendix C

    Vmux-2100 ver. 4.0 configuration menus c-1 appendix c configuration menus this appendix lists all menus of the vmux-2100 management software. Go to sheet 6 main menu 1. Inventory 2. Configuration 3. Monitoring 4. Diagnostics 1. System 2. Hub 3. Card 1. Main board (read only) 1-4. Slot 1/2/3/4 1. Mai...

  • Page 218

    Appendix c configuration menus installation and operation manual c-2 configuration menus vmux-2100 ver. 4.0 5. Show partition information 1. First partition 2. Second partition 1. Management 2. Control port 4. Factory default 3. Date & time update 7. Reset card 1. Host ip 2. Manager list 3. Host mux...

  • Page 219

    Installation and operation manual appendix c configuration menus vmux-2100 ver. 4.0 configuration menus c-3 2. Time slots configuration from sheet 1 sheet 3 1. Main board (m-ip) 1. Lan parameters 1. Set auto negotiation 2. Set default type 1. 10baset half duplex 2. 10baset full duplex 3. 100baset ha...

  • Page 220

    Appendix c configuration menus installation and operation manual c-4 configuration menus vmux-2100 ver. 4.0 7. Destination ssl/ hdlc/ transparent ch id from sheet 1 sheet 4 (e1) 2. Slot 1 (vca-2e1) 1. Group 1 1. Ip address 2. Bundles parameters 1. Display bundles 2. Bundle configuration 1. Add bundl...

  • Page 221

    Installation and operation manual appendix c configuration menus vmux-2100 ver. 4.0 configuration menus c-5 from sheet 1 sheet 4 (t1) 2. Slot 1 (vca-2t1) 1. Group 1 1. Ip address 2. Bundles parameters 1. Display bundles 2. Bundle configuration 2. Distribution of framer time slots 4. External 2 same ...

  • Page 222

    Appendix c configuration menus installation and operation manual c-6 configuration menus vmux-2100 ver. 4.0 from sheet 1 sheet 5 1. Group 1 2. Slot 1 (io-ml-2e1) 2. Slot 1 (io-ml-4e1) 2. Slot 1 (io-ml-2t1) 2. Slot 1 (io-ml-4t1) 2. Channelized bundles 1. External 1 2. External 2 1. Display bundles 2....

  • Page 223

    Installation and operation manual appendix c configuration menus vmux-2100 ver. 4.0 configuration menus c-7 sheet 6 3. Monitoring 4. Diagnostics 1. Inject tone test 2. Local loop test (voice cards only) 3. Remote loop test 4. Display active tests 5. Ping 1. Slot 2. Group number 3. External 4. Time s...

  • Page 224

    Appendix c configuration menus installation and operation manual c-8 configuration menus vmux-2100 ver. 4.0

  • Page 225: Index

    Vmux-2100 ver. 4.0 i-1 index —a— aal2ompls, 1-6 , 1-20 , 4-32 abcd bits, 4-9 access via telnet, 4-4 adapter cables for serial interface, a-5 adding users, 4-60 administrator, 3-10 administrator, 3-11 password, 3-11 user name, 3-11 alarm buffer, 6-29 , 6-31 permanent, 6-31 temporary, 6-29 alarms, 6-3...

  • Page 226

    Index installation and operation manual i-2 vmux-2100 ver. 4.0 interfaces, 2-4 main link, 2-5 management console, 2-6 modem, 2-6 power, 2-6 serial main link, 2-5 t1 voice port, 2-4 connectivity parameters, 4-33 connector pinouts cbl-vmux-mm-modem, a-3 control port, a-3 e1 port, a-1 ethernet utp, a-2...

  • Page 227

    Installation and operation manual index vmux-2100 ver. 4.0 i-3 connecting, 2-4 control, 2-6 e1 configuring, 4-22 e1/t1 connecting, 2-4 ethernet configuring, 4-19 main link e1/t1, 2-5 ethernet, 2-5 serial, 2-5 serial configuring, 4-20 t1 configuring, 4-26 unbalanced e1, 2-5 internal jumpers, setting,...

  • Page 228

    Index installation and operation manual i-4 vmux-2100 ver. 4.0 —p— package contents, 2-2 packet tracking, 6-7 packetizing interval, 1-15 , 4-33 , 4-45 parameters connectivity, 4-33 default values, 3-3 setting, 4-6 voice, 4-34 parameters choosing, 3-12 password, 3-11 administrator, 3-11 perceptual sp...

  • Page 229

    Installation and operation manual index vmux-2100 ver. 4.0 i-5 displaying, 4-54 e1 configuring, 4-25 statistics, 6-13 , 6-15 t1 configuring, 4-28 transparent, 4-45 tone injection, 6-37 tracking packets, 6-7 transparent jitter size, 4-38 transparent timeslots, 4-45 troubleshooting, 6-1 —u— udp, 1-18 ...

  • Page 230

    Index installation and operation manual i-6 vmux-2100 ver. 4.0

  • Page 231: Customer Response Form

    24 raoul wallenberg street, tel aviv 69719, israel tel: +972-3-6458181, fax +972-3-6483331, +972-3-6498250 e-mail: erika_y@rad.Com , web site: http://www.Rad.Com customer response form rad data communications would like your help in improving its product documentation. Please complete and return thi...

  • Page 233

    Error report incompatibility with product difficulty in understanding text regulatory information (safety, compliance, warnings, etc.) difficulty in finding needed information missing information illogical flow of information style (spelling, grammar, references, etc.) appearance type of error(s) or...

  • Page 236

    Publication no. 164-200-09/07 international headquarters 24 raoul wallenberg street tel aviv 69719, israel tel. 972-3-6458181 fax 972-3-6498250, 6474436 e-mail market@rad.Com north america headquarters 900 corporate drive mahwah, nj 07430, usa tel. 201-5291100 toll free 1-800-4447234 fax 201-5295777...