    Ric-e1 installation and operation manual e1 interface converter order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 2

    Order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 3: Notice

    Ric-e1 e1 interface converter installation and operation manual notice this manual contains information that is proprietary to rad data communications ltd. ("rad"). No part of this publication may be reproduced in any form whatsoever without prior written approval by rad data communications. Right, ...

  • Page 4: Limited Warranty

    Limited warranty rad warrants to distributor that the hardware in the ric-e1 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to distributor. If, during the warranty period, a...

  • Page 5: General Safety Instructions

    General safety instructions the following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety symbols this symbol may appear on the equipment or in the text. It in...

  • Page 6: Handling Energized Products

    Handling energized products general safety practices do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the off position or a fuse is blown. For dc-powered products, altho...

  • Page 7

    Connection of data and telecommunications cables data and telecommunication interfaces are classified according to their safety status. The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manu...

  • Page 8: Fcc-15 User Information

    To reduce the risk of fire, use only no. 26 awg or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 awg ou de section supérieure. Some ports are suitable for connection to intra-building or non-exposed wiring or cab...

  • Page 9

    Canadian emission requirements this class a digital apparatus meets all the requirements of the canadian interference-causing equipment regulation. Cet appareil numérique de la classe a respecte toutes les exigences du règlement sur le matériel brouilleur du canada. Warning per en 55022 (cispr-22) t...

  • Page 10: Declaration of Conformity

    Declaration of conformity manufacturer's name: rad data communications ltd. Manufacturer's address: 24 raoul wallenberg st. Tel aviv 69719 israel declares that the products: product names: ric-e1, ric-t1 conform to the following standard(s) or other normative document(s): emc : en 55022: 1998 inform...

  • Page 11: Quick Start Guide

    Installing ric-e1 1 quick start guide if you are familiar with ric-e1, use this guide to prepare it for operation. 1. Installing ric-e1 open the ric-e1 case by sliding the blue side panel forward and releasing the two screws located on the bottom panel at the rear end of the unit. Setting the intern...

  • Page 12

    Quick start guide ric-e1 installation and operation manual 2 operating ric-e1 jumper description values default setting jp2, jp3 select the e1 interface type balance – balanced interface (rj-45 connector) unbalance – unbalanced interface (bnc coax connectors) balance alb dte, jp4 enables local analo...

  • Page 13: Contents

    Ric-e1 installation and operation manual i contents chapter 1. Introduction 1.1 overview..................................................................................................................... 1-1 versions.....................................................................................

  • Page 14: List of Figures

    Table of contents ii ric-e1 installation and operation manual appendix a. Interface connector wiring appendix b. Ir-eth interface module appendix c. Ir-eth/v interface module appendix d. Ir-ip interface module appendix e. Ir-x.21b interface module list of figures 1-1. Typical application...............

  • Page 15: Chapter 1

    Overview 1-1 chapter 1 introduction 1.1 overview ric-e1 is an interface converter. It converts unframed hdb3 or ami data of itu g.703 e1 balanced or unbalanced interface into an interchangeable dte interface module. Ric-e1 operates at 2048 kbps. It extracts data and the clock from the g.703 interfac...

  • Page 16

    Chapter 1 introduction ric-e1 installation and operation manual 1-2 physical description application ric-e1 is typically used to connect between a g.703 network and a dte. The dte can be a multiplexer, a bridge, a router etc. Figure 1-1 illustrates a typical ric-e1 application. Dte v.35 ric-e1 g.703...

  • Page 17

    Ric-e1 installation and operation manual chapter 1 introduction functional description 1-3 1.3 functional description functional block diagram figure 1-3 shows the functional block diagram of ric-e1. Txd rxclk in te rc hang ab le i n te rf ac es rxd txclk loss tst ana liu x t rans fo rm er s clock g...

  • Page 18

    Chapter 1 introduction ric-e1 installation and operation manual 1-4 technical specifications 1.4 technical specifications link interface coding hdb3 or ami framing unframed bit rate 2.048 mbps impedance 120Ω, balanced 75Ω, unbalanced rcv signal level 0 to -10 db xmt signal level 3v (±10%), balanced ...

  • Page 19

    Ric-e1 installation and operation manual chapter 1 introduction technical specifications 1-5 diagnostics complies with itu v.54 (loop 3) local loopback activated by: • internal jumper (ric-e1) • front panel pushbutton (ric-e1/r) • dte circuit 141 for v.35, rs-530 and v.36 power ac source 100 to 240 ...

  • Page 20

    Chapter 1 introduction ric-e1 installation and operation manual 1-6 technical specifications order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 21: Chapter 2

    Package contents 2-1 chapter 2 installation and setup this chapter explains how to configure and install ric-e1. After the installation is complete, refer to chapter 3 for information about operating ric-e1. Refer to chapter 4 for troubleshooting and diagnostics information. 2.1 site requirements an...

  • Page 22

    Chapter 2 installation and setup ric-e1 installation and operation manual 2-2 configuring ric-e1 2.3 configuring ric-e1 this section provides information on the functions and locations of ric-e1 internal jumpers. Use this information to select the correct setting for your particular application. To ...

  • Page 23

    Ric-e1 installation and operation manual chapter 2 installation and setup configuring ric-e1 2-3 bal bnc loc ami hdb3 dte jp11 jp9 ana loop bal bnc jp6 jp 1 jp 2 jp 3 jp 4 tx & rx code int ext rcv j4 figure 2-1. Ric-e1 jumper locations table 2-1. Ric-e1 jumper settings jumper description values defa...

  • Page 24

    Chapter 2 installation and setup ric-e1 installation and operation manual 2-4 configuring ric-e1 selecting the impedance when ric-e1 uses the balanced interface: • terminate the impedance of g.703 link to 120Ω. • use only the rj-45 connector to transmit full duplex data to the g.703 network over utp...

  • Page 25

    Ric-e1 installation and operation manual chapter 2 installation and setup configuring ric-e1 2-5 connecting the dte ric-e1 supports various types of data channel interfaces. Equipment with v.35, x.21, rs-530 and ethernet interfaces can be connected directly to the ric-e1 dte port. The ric-e1 v.36 in...

  • Page 26

    Chapter 2 installation and setup ric-e1 installation and operation manual 2-6 configuring ric-e1 order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 27: Chapter 3

    Front panel indicators 3-1 chapter 3 operation this chapter describes how to operate ric-e1. Installation procedures explained in chapter 2 must be completed and checked before attempting to operate ric-e1. 3.1 front panel indicators figure 3-1 shows the ric-e1 front panel. The front panel indicator...

  • Page 28

    Chapter 3 operation ric-e1 installation and operation manual 3-2 operating instructions 3.2 operating instructions turning on ric-e1 starts operating as soon as ac or dc power is connected. Always connect the power cable to the ric-e1 power connector first and then to the mains outlet. The pwr led l...

  • Page 29: Chapter 4

    Performing local analog loopback 4-1 chapter 4 troubleshooting and diagnostics 4.1 performing local analog loopback ric-e1 supports activation of a v.54 diagnostic (loop 3) local loopback. This loopback checks the communication and connection between ric-e1 and the attached dte, as shown in figure 4...

  • Page 30

    Chapter 4 troubleshooting and diagnostics ric-e1 installation and operation manual 4-2 troubleshooting to activate the local analog loopback from the standalone ric-e1: 1. Open the ric-e1 case, as described in chapter 2 . 2. Set the jp11 jumper to loc. The analog loopback is activated and the tst in...

  • Page 31

    Ric-e1 installation and operation manual chapter 4 troubleshooting and diagnostics technical support 4-3 4.3 technical support technical support for this product can be obtained from the local distributor from whom it was purchased. For further information, please contact the rad distributor nearest...

  • Page 32

    Chapter 4 troubleshooting and diagnostics ric-e1 installation and operation manual 4-4 technical support order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 33: Chapter 5

    Asm-mn-214 card cage 5-1 chapter 5 ric-e1/r card this chapter describes the ric-e1/r card version, designed for installation in the asm-mn-214 card cage. The chapter contains the following sections: • the asm-mn-214 card cage • the ric-e1/r card version • power supply to ric-e1/r card • installing t...

  • Page 34

    Chapter 5 ric-e1/r card ric-e1 installation and operation manual 5-2 asm-mn-214 card cage ric-e1/r with one of the ethernet interfaces (ir-eth, ir-eth/ v or ir-ip) uses a cia/eth interface adapter, which converts one db-25 connector to an rj-45 connector. The adapter cable and interface attachments ...

  • Page 35

    Ric-e1 installation and operation manual chapter 5 ric-e1/r card power supply 5-3 5.2 power supply power is supplied to the ric-e1/r card from the asm-mn-214 power supply via the chassis. Each ric-e1/r card has two fuses (f5 and f6), which protect the entire system against power failure resulting fr...

  • Page 36

    Chapter 5 ric-e1/r card ric-e1 installation and operation manual 5-4 ric-e1/r front panel 5.3 ric-e1/r front panel figure 5-2 , figure 5-3 and figure 5-4 show the ric-e1/r card front panel options. The leds of the card version with serial dte interface are identical in their functionality to those o...

  • Page 37

    Ric-e1 installation and operation manual chapter 5 ric-e1/r card 5-5 figure 5-5. Asm-mn-214 front panel order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 38

    Chapter 5 ric-e1/r card ric-e1 installation and operation manual 5-6 installing the ric-e1/r card 5.4 installing the ric-e1/r card setting internal jumpers and switches figure 5-6 illustrates location of the internal jumpers on the ric-e1/r pcb. Alb dte pnl sw j2 f5 f6 jp 4 jp3 jp 2 dis dis en balan...

  • Page 39

    Ric-e1 installation and operation manual chapter 5 ric-e1/r card installing the ric-e1/r card 5-7 table 5-1. Ric-e1/r jumper settings (cont.) jumper description values default setting pnl sw, jp5 enables activation of the local analog loopback via the front panel pushbutton en – the llb can be activ...

  • Page 40

    Chapter 5 ric-e1/r card ric-e1 installation and operation manual 5-8 installing the ric-e1/r card 4. When operating ric-e1/r with unbalanced interface, use cia/tb-bnc/214 adapter, which converts the terminal block connector into two coaxial bnc connectors. 5. If required, attach the appropriate cia ...

  • Page 41: Appendix A

    V.35, x.21 and rs-530 interface connectors a-1 appendix a interface connector wiring a.1 v.35, x.21 and rs-530 interface connectors table a-1 lists the pin assignments of the v.35, x.21 and rs-530 interface connectors. Table a-1. V.35, x.21 and rs-530 interfaces, pin assignments v.35, 34-pin rs-530,...

  • Page 42

    Appendix a interface connector wiring ric-e1 installation and operation manual a-2 v.36 interface connector table a-1. V.35, x.21 and rs-530 interfaces, pin assignments (cont.) v.35, 34-pin rs-530, db-25 x.21, db-15 signal function pin circuit pin circuit pin [function] circuit transmit clock y aa s...

  • Page 43

    Ric-e1 installation and operation manual appendix a interface connector wiring line interface connector a-3 table a-2. Cable converting between rs-530 and v.36 interfaces, pin assignment (cont.) signal function v.36, 37-pin rs-530, 25-pin pin circuit pin circuit carrier detect 13 31 rr (a) rr (b) 8 ...

  • Page 44

    Appendix a interface connector wiring ric-e1 installation and operation manual a-4 line interface connector order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 45: Appendix B

    Introduction b-1 appendix b ir-eth interface module contents ir-eth interface module.............................................................B-1 b.1 i ntroduction ....................................................................................B-1 b.2 ir-eth o ptions ............................

  • Page 46

    Appendix b ir-eth interface module ric-e1 installation and operation manual b-2 ir-eth options b.2 ir-eth options standalone ric-e1 figure b-2 shows the rear panel of ric-e1 with the ir-eth module. Link tx rx 10base-t figure b-2. Rear panel of the ric-e1 with ir-eth module (10baset connector) table ...

  • Page 47

    Ric-e1 installation and operation manual appendix b ir-eth interface module ir-eth options b-3 act 100m los ric-e1 pwr link figure b-3. Ric-e1/r with ir-eth order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 48

    Appendix b ir-eth interface module ric-e1 installation and operation manual b-4 installation and operation b.3 technical specifications general lan table 10,000 addresses filtering and forwarding 15,000 frames per second buffer 256 frames delay 1 frame lan standard conforms to ieee 802.3/ethernet da...

  • Page 49

    Ric-e1 installation and operation manual appendix b ir-eth interface module installation and operation b-5 figure b-5. Ir-eth dip switch and led locations setting the dip switch table b-2 describes functions and default settings of the dip switch sw-1 sections. The dip switch is located on the rever...

  • Page 50

    Appendix b ir-eth interface module ric-e1 installation and operation manual b-6 installation and operation table b-4. Ir-eth led indicators, ric-e1/r led name description location color pwr on – ric-e1/r is powered up front panel green link on – lan is connected to the ir-eth module front panel gree...

  • Page 51: Appendix C

    Introduction c-1 appendix c ir-eth/v interface module contents c.1 i ntroduction .......................................................................................... C-1 c.2 ir-eth/v o ptions .................................................................................... C-2 standalone ri...

  • Page 52

    Appendix c ir-eth/v interface module ric-e1 installation and operation manual c-2 ir-eth/v options c.2 ir-eth/v options standalone ric-e1 figure c-2 shows the rear panel of the standalone ric-e1, equipped with ir-eth/v module. Table c-1 lists the module's rj-45 connector pinout. 100m link 10/100base...

  • Page 53

    Ric-e1 installation and operation manual appendix c ir-eth/v interface module ir-eth/v options c-3 ric-e1/r card figure c-3 illustrates the front panel of ric-e1/r with ir-eth/v. Act 100m los ric-e1 pwr link figure c-3. Ric-e1/r with ir-eth/v order from: cutter networks ph:727-398-5252/fax:727-397-9...

  • Page 54

    Appendix c ir-eth/v interface module ric-e1 installation and operation manual c-4 installation and operation c.3 technical specifications bridge lan table 2,048 mac addresses aging 5 minute, automatic latency (frame size 64 bytes) 10 mbps full duplex, 360 µs 100 mbps full duplex, 285 µs throughput 4...

  • Page 55

    Ric-e1 installation and operation manual appendix c ir-eth/v interface module installation and operation c-5 setting the dip switches configure the ir-eth/v module by setting the dip switches sw1 and sw2 in accordance with figure c-4 , table c-2 and table c-3 . Reset ric-e1 for changes in the flow c...

  • Page 56

    Appendix c ir-eth/v interface module ric-e1 installation and operation manual c-6 installation and operation backpressure and flow control dip switch sw1/4 enables or disables both backpressure and flow control. When the ir-eth/v is set to half duplex, backpressure is active, and when the ir- eth/v ...

  • Page 57: Appendix D

    Introduction d-1 appendix d ir-ip interface module contents d.1 i ntroduction ............................................................................................... D-2 application............................................................................................... D-3 d.2 t echni...

  • Page 58

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-2 introduction erasing configuration.............................................................................. D-25 resets menu........................................................................................... ...

  • Page 59

    Ric-e1 installation and operation manual appendix d ir-ip interface module technical specifications d-3 xdsl. Users on the lan who register with the ir-ip for an ip multicast group using the igsmp protocol filter ip multicast packets at wire-speed. Management and advanced configuration of the ir-ip ...

  • Page 60

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-4 physical description d.3 physical description standalone ric-e1 figure d-2 shows the rear panel of ric-e1 with the ir-ip module. Link tx rx setup on 10base-t act err int figure d-2. Rear panel of ric-e1 with the ir-ip mod...

  • Page 61

    Ric-e1 installation and operation manual appendix d ir-ip interface module physical description d-5 ir-ip leds ir-ip contains leds, which indicate the module activity. Table d-1 and table d-2 list the leds functions. Table d-1. Ir-ip leds functions (standalone ric-e1) led color function int green on...

  • Page 62

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-6 ir-ip management subsystem, general table d-3. Ir-ip controls control ric-e1 ric-e1/r function values default setting dip switch, section 1 ip learn pushbutton, dip switch, section 5 enables ir-ip to learn its ip on – ip ...

  • Page 63

    Ric-e1 installation and operation manual appendix d ir-ip interface module ir-ip management subsystem, general d-7 software downloading erasing user configuration resetting of various subsystems display of error log ping utility, for checking ip connectivity. The management subsystem of the ir-ip in...

  • Page 64

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-8 performing preliminary configuration rescue configuration in case you have forgotten the ip address or the telnet password, you will generally not be able to view or modify the ir-ip configuration. The rescue feature allo...

  • Page 65

    Ric-e1 installation and operation manual appendix d ir-ip interface module performing preliminary configuration d-9 connecting the telnet host before starting the management and configuration activities, it is necessary to establish ip communication between your telnet host and the ir-ip interface m...

  • Page 66

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-10 performing preliminary configuration the ip address is actually retrieved from the arp frames sent during pinging to locate the ping destination, not from the ping frames. To ensure that the process is correctly performe...

  • Page 67

    Ric-e1 installation and operation manual appendix d ir-ip interface module performing preliminary configuration d-11 after changing the destination ip address of the telnet host, it is recommended to turn ric-e1 off for a few seconds and then back on, before continuing the configuration of the ip ro...

  • Page 68

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-12 ir-ip management utility d.6 ir-ip management utility general operating procedures the ir-ip interface module is managed via a simple, menu-driven utility that uses a basic terminal user interface. A typical screen is sh...

  • Page 69

    Ric-e1 installation and operation manual appendix d ir-ip interface module quick setup menu d-13 menu structure of management utility figure d-7 shows the menu structure of the ir-ip management utility. Main menu 1. Quick setup 1. Lan ip address 2. Lan ip mask 3. Wan ip address 4. Wan ip mask 5. Def...

  • Page 70

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-14 quick setup menu lan ip address used to enter the ip address for the ip router lan interface. This is the address to which nodes connected to the local lan send packets addressed to the wan. Lan ip mask used to enter the...

  • Page 71

    Ric-e1 installation and operation manual appendix d ir-ip interface module quick setup menu d-15 operation with default gateway you can instruct ir-ip to send packets with destinations not located on the local lan to a specific router, which is called the default gateway. The default gateway must be...

  • Page 72

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-16 management access menu protocol used to select the wan protocol to be used by the ip router card: ppp, hdlc or frame relay. This parameter is available only if the read protocol from dip switches parameter is set to no. ...

  • Page 73

    Ric-e1 installation and operation manual appendix d ir-ip interface module advanced setup menu d-17 telnet inactivity timeout this parameter specifies the time a telnet session is kept open when there is no keyboard activity. When the specified time-out expires, the telnet session is closed and anot...

  • Page 74

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-18 advanced setup menu ir_ip s/w ver. 1.21 31/ir (date) quick setup management access advanced setup ..................................................................... Device identification ==============================...

  • Page 75

    Ric-e1 installation and operation manual appendix d ir-ip interface module advanced setup menu d-19 lan status used to enable/disable the flow of packets through lan interface: • open – the flow of packets is enabled. • closed – the flow of packets is disabled. As a result, ir-ip does not accept, no...

  • Page 76

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-20 advanced setup menu cir used to specify the maximum amount of data, in bits, which the frame relay network guarantees to transfer during the measurement interval (the measurement interval is usually one second). The valu...

  • Page 77

    Ric-e1 installation and operation manual appendix d ir-ip interface module advanced setup menu d-21 security host/guest this option can be used to configure the ip router either as a guest unit, to be authenticated by another router, or as a host unit, that authenticates other routers. User name to ...

  • Page 78

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-22 advanced setup menu ir_ip s/w ver. 1.21 31/ir (date) quick setup management access advanced setup ..................................................................... Device identification interface parameters protocol ...

  • Page 79

    Ric-e1 installation and operation manual appendix d ir-ip interface module device control d-23 static groups select this parameter to access the static multicast groups table. The table is used to specify the ip addresses for up to 10 ip multicast groups. To access the static groups menu: • from the...

  • Page 80

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-24 device control new software download menu ir-ip operates as a tftp client, and therefore it is possible to update its software by downloading new software from another computer that operates as a tftp server. The new sof...

  • Page 81

    Ric-e1 installation and operation manual appendix d ir-ip interface module device control d-25 erasing configuration selecting this item allows you to reset all the configuration parameters to their default values. • do this only if you need to reconfigure the module anew (all the parameters). • aft...

  • Page 82

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-26 view menu this operation restarts the ir-ip lan controller. To continue your telnet session, press any key within 15 seconds following the confirmation of the reset operation. Resetting the wan interface to reset the wan...

  • Page 83

    Ric-e1 installation and operation manual appendix d ir-ip interface module view menu d-27 ir_ip s/w ver. 1.21 31/ir (date) view configuration ------------------ boot version :x.Xx xx.Xx.Xxxx device name :ip router card system location :the location of this device contact person :name of contact pers...

  • Page 84

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-28 view menu multicast groups table screen this screen is used to display information about the multicast group ip addresses and their status. To access the multicast groups table screen: • in the view menu, type 3. The mul...

  • Page 85

    Ric-e1 installation and operation manual appendix d ir-ip interface module diagnostic tools (ping terminal) d-29 ir_ip s/w ver. 1.21 31/ir (date) system statistics ----------------- counter name val counter name val wan in octets 83504 wan alignment errors 0 wan out octets 1950 wan aborted frames 0 ...

  • Page 86

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-30 diagnostic tools (ping terminal) using the ping function the ping option is used to confirm ip connectivity by pinging other ip hosts. Connectivity is confirmed by receiving a reply from the remote (pinged) ip host. To p...

  • Page 87

    Ric-e1 installation and operation manual appendix d ir-ip interface module erasing ir-ip software d-31 d.13 erasing user’s configuration the user-defined configuration parameters are stored in the ip router card flash memory. After the user-defined configuration parameters are erased, the ip router ...

  • Page 88

    Appendix d ir-ip interface module ric-e1 installation and operation manual d-32 erasing ir-ip software erasing application software to erase the application software: 1. Turn ric-e1 off. 2. Set all the four sections of ir-ip dip switch to on. 3. Turn ric-e1 on and monitor the ip router err indicator...

  • Page 89

    Ric-e1 installation and operation manual appendix d ir-ip interface module erasing ir-ip software d-33 order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 90: Appendix E

    Introduction e-1 appendix e ir-x.21b interface module contents e.1 i ntroduction .................................................................................................E-1 application...................................................................................................E-1 rear...

  • Page 91

    Appendix e ir-x.21b interface module ric-e1 installation and operation manual e-2 selecting the ir-x.21b timing e.2 selecting the ir-x.21b timing ir-x.21b interface module supports two clock modes: • ext (external) • int/lbt (internal/receive). You must set the ir-x.21b clock to match the timing you...

  • Page 92

    Ric-e1 installation and operation manual appendix e ir-x.21b interface module selecting the ir-x.21b timing e-3 ir-x.21b ric-e1 dte txd txd txc etc etc rxc rxd rxd signal timing (rxc) (2, 9) (7, 14) (4, 11) (6, 13) fifo buffer rx fifo buffer tx figure e-4. Ext timing mode int/lbt clock mode the int/...

  • Page 93

    Appendix e ir-x.21b interface module ric-e1 installation and operation manual e-4 selecting the ir-x.21b timing order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 94: Index

    I-1 index —1— 10/100baset. See fast ethernet —3— 3d view, 1-2 —a— ac power connecting, 2-5 source, 1-5 supply, 5-3 application, 1-2 asm-mn-214 card cage, 5-1 —c— clock modes, 1-3 configuration, 2-2 connector pinout dte interface, a-1 ir-eth rj-45, b-2 ir-ip rj-45, d-6 —d— dc power connecting, 2-5 so...

  • Page 95

    Index product name installation and operation manual i-2 wan data rate, c-4 protocol, c-4 ir-ip aging timeout, d-19 arp tables, d-27 configuration screen, d-26 controls, d-5 device control menu, d-23 diagnostic tools, d-29 dip switch, d-5 displaying statistics, d-28 erasing configuration, d-31 inter...

  • Page 96: Customer Response Form

    24 raoul wallenberg st., tel aviv 69719, israel tel: +972-3-6458181, fax: +972-3-6483331, +972-3-6498250 e-mail: , web site: customer response form rad data communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us a...

  • Page 97: Error Report

    Error report type of error(s) ❒ incompatibility with product or problem(s): ❒ difficulty in understanding text ❒ regulatory information (safety, compliance, warnings, etc.) ❒ difficulty in finding needed information ❒ missing information ❒ illogical flow of information ❒ style (spelling, grammar, re...

  • Page 98

    Order from: cutter networks ph:727-398-5252/fax:727-397-9610 www.Bestdatasource.Com.

  • Page 99

    900 corporate drive, mahwah, n.J. 07430, tel: (201) 529-1100 toll free: 1-800-444-7234, fax: (201) 529-5777, email: market@radusa.Com www.Rad.Com 24 raoul wallenberg street, tel aviv 69719, israel, tel: 972-3-6458181 fax: 972-3-6498250, 972-3-6474436, email: market@rad.Com u.S. Headquarters: interna...