  • Page 1

    Item no. 3248 03 66/3248 03 61 duofern standard manual transmitter operating instructions .................................................................... 27 en vbd 473-2 (05.13).

  • Page 2: Dear Customer ...

    28 28 en …in purchasing this duofern standard manual transmitter, you have decided on a quality product manufactured by rademacher. We would like to thank you for your confidence. This manual transmitter has been developed with such aspects as optimum operability and convenience in mind, as well as ...

  • Page 3: Contents

    29 29 en contents i dear customer ... .............................................28 general view/operating elements ..................30 rear side of device ..........................................31 key to symbols ................................................32 general safety advice ...........

  • Page 4

    30 30 en . . . General view/operating elements i led-status up (on/off) down (on/off) stop (off) device buttons or group buttons green orange item no.: 3248 03 61 item no.: 3248 03 66 * switching jog mode on/off.

  • Page 5: Rear Side of Device

    31 31 en i rear side of device space for note disconnect button fixing screw 1 x 2 x hold for 5 s disconnect mode end point setting reset 1 x 2 x hold for 5 s item no.: 3248 03 66 3248 03 61 example of identification plate for item no. 3248 03 66 connect button registering mode reversal of rotationa...

  • Page 6: Key to Symbols

    32 32 en stop stop note note/important/caution this heading indicates information that is important to the proper functioning of the device. This symbol advises of malpractices that may cause damage to people and property. This concerns your safety. Please pay particular attention to and carefully f...

  • Page 7: Improper Use

    33 33 en i use the duofern standard manual transmitter only for the remote control of: ◆ roller shutters ◆ electrical consumers (e.G. Lighting) operating conditions ◆ the duofern radio system may only be operated with and installed in systems and devices in which transmitter or receiver faults do no...

  • Page 8

    34 34 en short description of the duofern standard manual transmitter i the duofern wireless system enables bidirectional data exchange between the various participants of a wireless network. All switching commands from a duofern transmitter will be confirmed by the duofern receivers. Using the duof...

  • Page 9

    35 35 en i list of models with number of controllable groups and duofern end devices. Item no.: 3248 03 66 3248 03 61 number of groups 6 1 number of end devices for each group 8 48 maximum number of end devices 48 48 disconnect button you can call up the following functions with the disconnect butto...

  • Page 10

    36 36 en . . . ▲ 1 x 2. 1. 3. 1 x register duofern end devices (applies to item no. 3248 03 66) in order to be able to operate a duofern end device with the duofern standard manual transmitter, this must be registered with the duofern end device concerned. Tip use a thin, not too sharp object to pre...

  • Page 11

    37 37 en . . . 1. ... 4. 4. 5. 1. ... 4. Register duofern end devices (applies to item no. 3248 03 66) press the desired device button that you wish to use later to select the device. Observe the status led green: the registration was successful. Orange: the button is already fully allocated. Repeat...

  • Page 12

    38 38 en register duofern end devices (applies to item no. 3248 03 61) no devices or group buttons can be selected or pressed for duofern standard manual transmitter 3248 03 61. The registered actuators are automatically allocated to the only existing group. Note ◆ when registering actuators with se...

  • Page 13

    39 39 en ▲ 2. 1. 1 x 3. 4. Observe the status led green: the registration was successful. Orange: the button is already fully allocated. Register duofern end devices (applies to item no. 3248 03 61) switch the desired duofern end device or duofern actuator to registering mode. (see corresponding ope...

  • Page 14: Delete Duofern End Devices

    40 40 en ▲ 1. 3. 1 x 2. Delete duofern end devices switch desired duofern end devices to delete mode. (see corresponding operating instructions) if the deletion is successful the green status led lights up. Note the duofern end device has been deleted from all device buttons or group buttons. Switch...

  • Page 15: End Point Setting

    41 41 en . . . 2. 1. End point setting you can subsequently set or correct the end points of connected tubular motors using this function. Note ◆ the end point setting can only be adjusted when only one device (actuator) is registered within the selected group ; if more than one component is registe...

  • Page 16: End Point Setting

    42 42 en ▲ 3. 4. 5. 6. 7. 8. End point setting the status led flashes (approx. Twice per second) on successful activation. Set the upper end point. Keep the button pressed until the desired end point is reached. Release the button as soon as the upper end point is reached. Set the lower end point. R...

  • Page 17

    43 43 en reversal of rotational direction you can subsequently set or correct the rotational direction of connected tubular motors using this function. Alternative use for reversal of directional rotation: switch over between lighting function and device function in case of universal actuators for l...

  • Page 18

    44 44 en . . . ▲ ▲ 2. 1. 3. I) reversal of rotational direction select the desired duofern end device. Activate the “reversal of rotational direction” func- tion. In order to do so, press the “connect” button twice in short succession within one second (similar to the double-click of a computer mous...

  • Page 19

    45 45 en ▲ 1. Activate “purge“ function this function deletes all duofern end devices that are registered but that no longer react. This could be necessary, for example, in the case of a faulty device which can no longer be deleted as described above. ◆ all battery powered duofern devices are not to...

  • Page 20: Manual Operation

    46 46 en . . . 1. 2. 3. 4. Manual operation of actuators with several channels when registering actuators with several channels, all channels in the group are always registered for duofern standard manual transmitter 3248 03 61 (1 group). Operation of single channels is therefore not possible using ...

  • Page 21

    47 47 en . . . 1. 2. . . . 3 x + approx. 10 s controlling blinds and dimmers in jog mode functional description of jog mode ◆ if the up and down buttons are pressed briefly in jog mode, a jog command is transmitted. This enables convenient adjustment of venetian blind slats, as the motor only runs b...

  • Page 22: Delete Settings (Reset)

    48 48 en 1. 2. Delete settings (reset) press the “disconnect” button for approx. 5 seconds until the orange status led flashes. The status led flashes orange let go of the „disconnect button“ as soon as the orange status led is permanently lit up all settings on the duofern standard manual transmitt...

  • Page 23: Technical Data

    49 49 en technical data td transmission frequency: 434,5 mhz transmitting power: 10 mw range: - free field: approx. 100 m - indoors: approx. 30 m (depending upon the building fabric) supply voltage: 3 v battery type: cr2450 - service life 1: approx. 2 years, if actuated 5 times per day - service lif...

  • Page 24: Battery Change

    50 50 en if the battery is almost empty, the status led flashes orange when you operate the duofern standard manual transmitter. ◆ the battery can be found in the battery compartment on the rear of the duofern standard manual transmitter. ◆ unfasten the rear housing with a screwdriver. ◆ carefully l...

  • Page 25: Ce Mark and Ec Conformity

    51 51 en the duofern standard manual transmitter (item no. 3248 03 66/3248 03 61 )complies with the requirements of the current european and national directives. Ce mark and ec conformity i 1999/5/ec r&tte directive conformity has been verified. The corresponding declarations and documentation are a...

  • Page 26: Warranty Conditions

    52 52 en subjec t t o t echnic al modific ations , misprin ts and err ors e xc ept ed . Illustr ations not binding . Rademacher geräte-elektronik gmbh & co. Kg buschkamp 7 46414 rhede (germany) info@rademacher.De www.Rademacher.De warranty conditions rademacher geräte-elektronik gmbh&co. Kg offers a...