Radiant EASYREMOTE Instruction Manual

Manual is about: remote control device

Summary of EASYREMOTE

  • Page 1

    Easyremote - rad - ing - man.Inst - 1010b - 40-00017 technical specification radiant bruciatori s.P.A. Montelabbate (pu) italy english instruction manual remote control device easyremote.

  • Page 3

    General information technical features supply by communication bus number of temperature levels 2 (day / night) temperature setting range day 5 ÷ 30 °c temperature setting range night 5 ÷ 30 °c temperature setting range manual 5 ÷ 30 °c differential operation temperature off 0.0 ÷ 1.0 °c differentia...

  • Page 4: Caution

    General information dear customer, our compliments for buying the remote control device easyremote, a product of latest technologies which will give you superior comfort. In order to get top performance and to learn how to best use features and functions of this remote control device, carefully read...

  • Page 5

    General information a select operation status b set time and temperature c weekly program d change displayed value (turn) select automatic / manual (press) e alarm reset f select temperature level (day/night) g temperature display.

  • Page 6

    General information lcd symbols icon steady blinking current temperature fault code time/temperature current day of the week change day of the week domestic hot water enabled domestic hot water requested heating enabled heating requested manual mode burner on heating program change heating program s...

  • Page 7

    Contents 1. How to use this instruction booklet ………...…………….………………..…1 2. General instructions.………………………………………………………...…..2 3. Main features…………………………………………………………..………...3 4. Installation….……………………………………………………………..……...4 5. Configurating operating parameters………..………………………………….8 6. Disabling thermo-r...

  • Page 8: Some Hints

    Installer instructions 1 1. How to use this instruction booklet this booklet is divided into two sections, each of which having its own addressee: • installer section, this gives instructions regarding the accurate installation and configuration of the remote control device. • user section, this giv...

  • Page 9: General Instructions

    Installer instructions 2 2. General instructions • carefully read this manual because it will give you important instructions regarding the safety of use, installation and maintenance. • the system must be implemented in compliance with the safety regulations in force. • after unpacking and before i...

  • Page 10: Main Features

    Installer instructions 3 3. Main features the easyremote remote control device has been designed to guarantee ideal temperature conditions at any moment of the day offering the possibility to set the boiler from remote. The programming of the easyremote remote control device is extremely easy a larg...

  • Page 11: Installation

    Installer instructions 4 4. Installation the easyremote remote control device must be installed only by expert personnel. To correctly install the device and in compliance with the regulations in force about electrical appliances, use a dedicated line to connect it. In case this is impossible, any i...

  • Page 12

    Installer instructions 5 1. Cut off electricity from boiler. 2. Use a screwdriver and gently press on the two lower splines to take off the device from the back of its fixing template. 3. Insert both ends of the connecting wire into their proper seat on the fixing template. Use the proper holes to i...

  • Page 13

    Installer instructions 6 4. Connect electricity to the terminal box. N.B.: the connection is not polarized. 5. Fix your remote control device to its template. First insert the upper part and then press and turn until its completely closed. 6. Check in the boiler if there is a request to eliminate th...

  • Page 14

    Installer instructions 7 7. Supply power to the boiler. Now the installation is completed. If it was done correctly the remote control device is now powered and the lcd display will show the following message for a few seconds: as soon as the connection is established the normal operating condition ...

  • Page 15: Will Show Par.

    Installer instructions 8 5. Configurating operating parameters this operation must be done by technical service personnel only. Errors in the configuation of your easyremote remote control device may lead to malfunctioning. This operation configures the remote control device to be compatible with th...

  • Page 16

    Installer instructions 9 4.Turn button to select the parameter number to be displayed. The temperature display will show the corresponding parameter value. 5. Press button : to change this value. The corresponding parameter value will start blinking. 6. Turn button to change the displayed value. 7. ...

  • Page 17

    Installer instructions 10 hereafter you can find the definition of parameters you can change: • p00 - room temperature sensor compensation it is the value (-5.0°c ÷ +5.0°c) to be added to/detracted from the displayed room temperature in order to compensate any possible error. • p01 - room anti-frost...

  • Page 18

    Installer instructions 11 tset point - p03 = 20.0 - 0.5 = 19.5 °c the central heating demand starts whenever the room temperature is lower then 19.5°c. • p04 - thermo-regulation type 0 = on/off 1 = modulating on room temperature sensor 2 = modulating on external temperature sensor (outside temperatu...

  • Page 19: Disabling Thermo-Regulation

    Installer instructions 12 6. Disabling thermo-regulation in case the remote controller is installed inside a generic environment and you do not need to control its temperature (i.E.Garage, boiler room…), you can disable the central heating demand request trough proper configuration of parameter p04 ...

  • Page 20: Boiler Configuration (Tsp)

    Installer instructions 13 7. Boiler configuration (tsp) this operation must be carried out by technical assistance personnel exclusively. The remote control device does not know the meaning of what appears on the display but only acts as a “graphic interface” for the boiler electronic board. The num...

  • Page 21: Selecting Operating Mode

    User instructions 14 8. Selecting operating mode subject to the type of boiler connected, some of the following modes may not be available. Select the operating mode of the boiler by pressing key several times. The operating modes you can set are: selected status id icons off summer winter only heat...

  • Page 22

    User instructions 15 2. Summer: the boiler is enabled to only produce domestic hot water. 3. Winter: the boiler is enabled to produce domestic hot water and to heat the room..

  • Page 23

    User instructions 16 4. Only heating: the only operation mode enabled is heating. No matter which function has been selected, the room anti-freeze function is always operative (cfr. Respective section)..

  • Page 24: May Not Be Available.

    User instructions 17 9. Setting up clock and temperature subject to the type of boiler connected, some of the following modes may not be available. To set the clock and the temperature set points of this remote control device and of the boiler press key several times. The menu is as follows: selecte...

  • Page 25: 9.1.

    User instructions 18 9.1. Setting up clock 1. Press key : the hour will blink. 2. Turn button to set the requie value. 3. Press button to confirm the input value. The hour will stop blinking and the minutes will start blinking..

  • Page 26

    User instructions 19 4. Turn button to set the value you want. 5. Press button to confirm value. The minutes stop blinking and the day of the week will start blinking. 6. Turn button to set the value you want. 7. Press button to confirm value. The day of the week stops blinking and icon goes off..

  • Page 27: 9.2.

    User instructions 20 9.2. Setting up room day temperature 1. Press key until icon starts blinking. 2. Turn button to set the value you want..

  • Page 28: 9.3.

    User instructions 21 9.3. Setting up room night temperature 1. Press key and release when icon starts blinking. 2. Turn button to set the temperature you want..

  • Page 29: 9.4.

    User instructions 22 9.4. Setting up heating temperature if the remote control device has been configured as modulating, this parameter determines the max. Temperature value as computed by the modulation algorithm. 1. Press key until icon starts blinking. 2. Turn button to set the value you want..

  • Page 30: 9.5.

    User instructions 23 9.5. Setting up domestic hot water temperature 1. Press key until icon starts blinking. 2. Turn button to set the value you want..

  • Page 31: 9.6.

    User instructions 24 9.6. Setting up outside probe kd value this setting option is available only if the outside probe is connected, the remote control device is set as modulating and the use of the outside probe for modulation (p04 = 2 or 3) is enabled. This parameter allows to select a curve to de...

  • Page 32

    User instructions 25 flow temperature calculation diagram.

  • Page 33: 10.

    User instructions 26 10. Setting up clock and temperatures if the operation mode selected is winter or heating only, the easyremote device allows you to manipulate the room temperature either manually or automatically. • in manual mode the user selects the room temperature he wants, and this tempera...

  • Page 34: 10.1.

    User instructions 27 10.1. Manual operation 1. Press key until icon appears. The central digits on the display will show the set temperature blinking. 2. Turn button to set the temperature you want. 3. After 30 secs the central display will go back to showing the current temperature. 4. The set temp...

  • Page 35: 10.2.

    User instructions 28 10.2. Automatic operation 1. Press button until the heating clock corona will be displayed. 2. Icon or will light up to show which is the currently set temperature level..

  • Page 36: 11.

    User instructions 29 11. Weekly heating program when operation mode winter or heating only is selected, the remote control device allows operation in automatic mode in which a priorly set program manages the room temperature during the various times of the day. The room temperature can be set to two...

  • Page 37: 11.1.

    User instructions 30 11.1. Display heating program 1. Press key . Icons prog and will appear on the display and show the first day of the week. Icons / and the jumper are on or off matching the day / night level of the displayed time. 2. Turn button in order to scroll the times of the day and to mov...

  • Page 38: 11.2.

    User instructions 31 11.2. Change heating program 1. Press key . Icons prog and will appear on the display and show the first day of the week. Icons / and the jumper are on or off matching the day/night level of the displayed time. 2. Press button to go to the program change zone: icon prog and the ...

  • Page 39: 12.

    User instructions 32 12. Weekly storage tank program this function is available only if the boiler connected to the remote control device has been designed to control it. The easyremote remote control device can run (same as for heating program) a weekly program to enable ( ) or disable ( ) the stor...

  • Page 40: 12.1.

    User instructions 33 12.1. Display storage tank program 1. Press key . Icons prog and will appear on the display and show the first day of the week. 2. Press key . Icon will light up on the display and show the storage tank program. Icon (storage tank enabled) or (storage tank disabled) and the jump...

  • Page 41: 12.2.

    User instructions 34 12.2. Change storage tank program 1. Press key . Icons prog and will appear on the display and show the first day of the week. 2. Press key . Icon will light up on the display and show the storage tank program. Icons (storage tank enabled) or (storage tank disabled) and the jump...

  • Page 42: 13.

    User instructions 35 13. Temporary change room temperature set point when operating in automatic mode the room set point day ( ) / night ( ) can be increased or reduced. The change will be valid until the next level change (day-night) takes place. Thereafter it will be void. 1. Press key to display ...

  • Page 43: 14.

    User instructions 36 14. Fault signalling the remote control device will display any faults with code exx blinking in place of the temperature display. To learn about the type of fault refer to the boiler instruction booklet. There can be two kinds of faults: those which can be restored by the user ...

  • Page 44: 14.2.

    User instructions 37 14.2. Not restorable faults you recognize these faults because icon will light up; these faults cannot be reset by the user but require technical service. Also code e66 falls under this error class (room temperature probe of remote control device in fault)..

  • Page 45: 15.

    User instructions 38 15. Display values subject to the type of boiler connected some of the below described functions may not be available. Pressing key repeatedly your easyremote control device is able to display the following quantity values: selected quantity id icon set room temperature domestic...

  • Page 46: 15.1.

    User instructions 39 15.1. Display set room temperature this is the temperature set for the activated temperature level (day - night - manual). 15.2. Display temperature domestic hot water probe this is the temperature read by the domestic hot water probe fitted in the boiler..

  • Page 47: 15.3.

    User instructions 40 15.3. Display temperature delivery probe this is the temperature read by the delivery probe fitted in the boiler. 15.4. Display temperature outside probe this is the temperature read by the outside probe connected to the boiler..

  • Page 48: 16.

    User instructions 41 16. Reset of default values if necessary the original values of the remote control device as set by the manufacturer can be restored. The restored values are as follows: • temperature day: 20°c • temperature night: 16°c • temperature manual: 20°c weekly heating program days nigh...

  • Page 49

    User instructions 42 1. Move the remote control device to off position. 2. Press keys and and keep them pressed for longer than 5 secs. 3. The operation is confirmed when def appears on the display..

  • Page 50: 17.

    User instructions 43 17. Complete resetting faults or other technical reasons may require ‘complete resetting’ of the remote control device. For this operation the remote control device must be taken off its fixing template - do this by gently pressing with a screwdriver on the lower splines. Therea...

  • Page 51: 18.

    User instructions 44 18. Funzione antigelo ambiente the easyremote controller is able to support the room-antifrost function. In all the operating modes the central heating demand is generated whenever the measured room temperature is lower then the activation threshold (parameter p01). This grants ...

  • Page 52

    Radiant bruciatori s.P.A. Via pantanelli, 164/166 - 61025 loc. Montelabbate (pu) tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: tecnico@radiant • internet: http://www.Radiant.It the technical data and measurements are provided for information purposes only and are not binding. The company rese...