2.0.2. LOCAL-CONTROLLER
The Local–Controller unit is equipped with a sensor
that measures the room temperature displayed on
the APP iMODULE.
The Local–Controller allows the User to set, in
MANUAL mode, the desired room temperature
using the adjustment dial.
KEY OF USER INTERFACE (SEE FIG.1)
1. Dial: used to set the room temperature within
the range from 10°C to 30°C, valid fro MANUAL
mode only;
2. Green LED:
· Steadily Lit: MANUAL mode enabled (boiler
controlled by the Local-Controller).
· Flashing Slowly: AUTOMATIC mode enabled
(boiler controlled by the APP iMODULE).
· Flashing Quickly: MANUAL mode enabled
(power has been cut off to Receiver iModul,
the boiler is controlled directly by the Local-
Controller);
3. Push button: hold it down for three seconds
to switch from AUTOMATIC to MANUAL mode
and vice versa;
4. Red LED:
· Steadily Lit: failed communication between
Open-Therm amd Receiver iModule or boiler;
· LED off: no failure;
· Flashing Slowly: Room sensor failure (on
Local-Controller);
· Flashing Quckly: Receiver iModule failure (no
communication to APP iModule).
·