  • Page 1

    Ce 0694 english technical specification radiant bruciatori s.P.A. Montelabbate (pu) italy by technical department installation and maintenance manual for gas fired, wall - hung boilers model rbs 20 e type c room sealed.

  • Page 3

    User manual combi – cod. 99941na – november 2002 index installation instructions and warnings page 1 technical data page 2 overall dimensions - exhaust flue system page 3 general installation requirements page 4-5 boiler installation page 6-7 electrical connections page 8-14-15 boiler control panel ...

  • Page 4

    Installation manual combi – cod. 99941na – november 2002 1 the friendly power of heat thank you for choosing radiant declaration for purposes of art. 7 of law 46 of 5 april 1990. Radiant bruciatori s.P.A. Hereby declares that all of its products are constructed to industry standards as required by t...

  • Page 5

    Installation manual combi – cod. 99941na – november 2002 2 technical specification type c device type c devices are devices in which the combustion circuit (air intake, combustion chamber, exchanger, combustion exhaust) is sealed off from the place where they are installed . Central heating – d.H.W....

  • Page 6

    Installation manual combi – cod. 99941na – november 2002 3 type c wall-mounted boilers sealed combustion circuit: kit a. Horizontal coaxial exhaust flue system with 360° rotation. It allows the flue exhaust and the air intake directly to an external wall. . N.B.: to insert a bend in the flue, reduce...

  • Page 7

    Installation manual combi – cod. 99941na – november 2002 4 general installation requirements gas safety it is the law that all gas appliances are installed by a corgi registered installer (you can check this by contacting corgi on 01256.372200) in accordance with the regulations listed below. Failur...

  • Page 8

    Installation manual combi – cod. 99941na – november 2002 5 where installation will be in an unusual location, special procedures may be necessary. Bs 6798 gives detailed guidance on this aspect. For clearances to be made available for installation and servicing, see sections 5.2.2. To 5.2.4. Flue po...

  • Page 9

    Installation manual combi – cod. 99941na – november 2002 6 cold water inlet r g f a r c g r hot water oulet return flow gas g c f a c f a fig. 3 boiler installation - minimum distances for fixing to wall to allow access inside the boiler for maintenance operations, the minimum distances shown in fig...

  • Page 10

    Installation manual combi – cod. 99941na – november 2002 7 gas connections the gas supply must be connected up by a corgi registered fitter. The following standards must be complied with: unicig 7131/72 and unicig 7129/92 (of 21/04/93) before installing the boiler, make sure of the following: the pi...

  • Page 11

    Installation manual combi – cod. 99941na – november 2002 8 vt 1 2 black black brown light blue yellow/green black brown yellow/green light blue ta ta 5 ta l n or n l or 1 2 3 4 5 4 3 2 1 m m ta pt ta or l n n l or ta pt pt re d ye llow blu e bro w n re d ye llow blu e bro w n shuko plug mains for u....

  • Page 12

    Installation manual combi – cod. 99941na – november 2002 9 pump cup valve cap circulating pump air vent valve air vent if a timer is fitted as well as a room thermostat, carry out the electrical connections for the timer according to the indications in figures 6-7. Instrument panel legend (see fig. ...

  • Page 13

    Installation manual combi – cod. 99941na – november 2002 10 starting up the boiler • open the gas cock; • turn on the boiler; • set the selector to winter; • make sure that 6 and 7 light are on (fig.2 p.10 pos. 6 and 7) on the boiler panel. If light no. 5 is on, it means water deficiency in the syst...

  • Page 14

    Installation manual combi – cod. 99941na – november 2002 11 regulating the max. And min. Modulation gas pressure to regulate the maximum gas pressure to the burner proceed as follows: • connect a gauge into the pressure socket b (fig.1). • remove the aluminium protective cap from screw a (fig.1) cou...

  • Page 15

    Installation manual combi – cod. 99941na – november 2002 12 tr1 fu se 2 a tr2 cm1 p2 min.Gas cm1 cm1 selector selector link disabled on cm1 selector. Timing 3 min. Timing 0 min. Link inserted on cm1 selector. Gas type conversion conversion of the boiler from natural gas to lpg and vice versa must be...

  • Page 16

    Installation manual combi – cod. 99941na – november 2002 13 6 10 4 2 3 8 1 9 18 5 16 12 11 14 13 15 17 technical data differential pressure switch for fan control to guarantee maximum safety in flue exhaust, a differential pressure switch is installed on the room sealed models. This air pressure swi...

  • Page 17

    Installation manual combi – cod. 99941na – november 2002 14 31 30 bla ck m7 33 32 34 35 36 nc bro w n bro w n blu e blu e c bla ck no par - air pressure swtich - fan ev m6 m4 m3 m1 m5 m7 m2 ev par - ionisation electrode - ignition electrode - time clock - room thermostat - summer-winter switch ta e....

  • Page 18

    Installation manual combi – cod. 99941na – november 2002 15 rbs 20 e wiring diagram.

  • Page 19

    Installation manual combi – cod. 99941na – november 2002 16 maintenance to keep the boiler in efficient and safe operating condition, we recommend that the following checks are performed at least once a year (according to reference standards): • check all seals on the gas components and replace gask...

  • Page 20

    Installation manual combi – cod. 99941na – november 2002 17 short list n° code description rbs 20 e electronic ignition 1 58008la main heat exchanger 2 36066la electronic gas valve vk4105 g1112 3 76631la electronic ignition board s4565qm1012 4 76646la printed circuit board sm 20013 5 73507la heating...

  • Page 22

    C ode 99941n a • n o vem ber 2002 radiant bruciatori s.P.A. Registered office: 61025 montelabbate (pu) italy • via pantanelli, 164 phone +39 0721 90791 15 linee telefax. +39 0721 9079299 (italy) - +39 0721 9079279 (export) email: italia@radiant.It • tecnico@radiant.It • export@radiant.It internet: h...