Radiant SF 16 E Installation And Maintenance Manual

Other manuals for SF 16 E: User Manual

Summary of SF 16 E

  • Page 1

    Ce 0694 english technical specification radiant bruciatori s.P.A. Montelabbate (pu) italy by technical department installation and maintenance manual for gas fired heater model sf 16 e type c room sealed.

  • Page 3

    Index installation instructions and warnings page 1 technical data page 2 overall dimensions - exhaust flue system page 3 general installation requirements page 5 boiler installation page 6 gas operations and adjustments page 8 regulating the gas pressure page 9 electrical connections page 10-12 boi...

  • Page 4

    Installation manual gas fire heater – cod. 99962na – november 2002 1 the friendly power of heat thank you for choosing radiant declaration for purposes of art. 7 of law 46 of 5 april 1990. Radiant bruciatori s.P.A. Hereby declares that all of its products are constructed to industry standards as req...

  • Page 5

    Installation manual gas fire heater – cod. 99962na – november 2002 2 technical specification type c device type c devices are devices in which the combustion circuit (air intake, combustion chamber, exchanger, combustion exhaust) is sealed off from the place where they are installed . Central heatin...

  • Page 6

    Installation manual gas fire heater – cod. 99962na – november 2002 3 overall dimensions kit. A. Horizontal coaxial exhaust system, revolves 360°: for flue exhaust and inlet of air from external wall. N.B.: to insert a flue bend, reduce total length of exhaust 0.8 m. Kit. B. Double system, revolves 3...

  • Page 7

    Installation manual gas fire heater – cod. 99962na – november 2002 4 general installation requirements gas safety it is the law that all gas appliances are installed by a corgi registered installer (you can check this by contacting corgi on 01256.372200) in accordance with the regulations listed bel...

  • Page 8

    Installation manual gas fire heater – cod. 99962na – november 2002 5 where installation will be in an unusual location, special procedures may be necessary. Bs 6798 gives detailed guidance on this aspect. For clearances to be made available for installation and servicing, see sections 5.2.2. To 5.2....

  • Page 9

    Installation manual gas fire heater – cod. 99962na – november 2002 6 distances for fixing to wall the water heater must be installed in a suitable wall. The water heater must not be fitted in a cupboard or cabinet and to allow access for maintenance operations, the minimum distances shown below must...

  • Page 10

    Installation manual gas fire heater – cod. 99962na – november 2002 7 water and gas connection for the installation respect national standards and safety norms. Gas connection - the pipe must have sufficient section with respect to its length and to necessary flow rate, and must be equipped with all ...

  • Page 11

    Installation manual gas fire heater – cod. 99962na – november 2002 8 gas operation and adjustments conversion of the water heater from natural gas to lpg and vice versa must be performed by qualified personnel only. Conversion is performed as follows: 1 - make sure to disconnect the power supply and...

  • Page 12

    Installation manual gas fire heater – cod. 99962na – november 2002 9 gas valve modulation minimum and maximum gas pressure setting adjust burner gas pressure through screw a (fig.3) as follows: ♦ undo the screw of pressure point b (fig.3) and insert a pressure gauge. ♦ unscrew and remove the alumini...

  • Page 13

    Installation manual gas fire heater – cod. 99962na – november 2002 10 electrical connections the boiler works with 230 v 50 hz ac current and has maximum input of 170 w. Connection to the electrical mains must be performed with a device having an omnipolar opening of at least 3 mm. Make sure the liv...

  • Page 14

    Installation manual gas fire heater – cod. 99962na – november 2002 11 electric wiring diagrams lb vg tl cvi- m pa sp st lf lt ev 10 koh m 25 °c re qu e s t o f ig n it ion b y fl o w m e te r on /o ff on=2 ,2 l/m o f f= 1, 7l /m p sign a l 0 /1 00 % re gu l a t o r p2 te m p e r a t ur e re gu l a t...

  • Page 15

    Installation manual gas fire heater – cod. 99962na – november 2002 12 ca bl e el . M ai n s lig h tb lu e br o w n elec tr od e io n is at io n ig ni tio n elec tr o d e l n l 1 gr ey 9 8 6 5 3 2 1 4 bl a c k 4 x1 x2 2 1 3 f1 2 at 5 1 3 4 6 7 9 s f 1 6 e - wir in g dia g ram lig htb lue brow n ig x3...

  • Page 16

    Installation manual gas fire heater – cod. 99962na – november 2002 13 instrument panel legend: 1. On/off switch 2. D.H. Water temperature setting knob (40 - 60 °c) 3. Power indicator 4. D.H.Water operation indicator 5. Reset button preliminary operations make sure that the gas cock and all water tap...

  • Page 17

    Installation manual gas fire heater – cod. 99962na – november 2002 14 malfunction possible cause remedy the water heater doesn’t work gas and water tap opened power indicator on d. Hot water operation indicator off _ rotative flow meter _d. Hot water 1/8” sensor _fuse _main circuit board (see table ...

  • Page 18

    Installation manual gas fire heater – cod. 99962na – november 2002 15 unpacking a set the packed water heater on the floor. Make sure the arrow is pointing up. B remove the tape and open the 4 flaps toward the outside. C remove the inside cardboard packing. D hold the water heater from the rear (fra...

  • Page 20

    C ode 99963n a • n o vem ber 2002 radiant bruciatori s.P.A. Registered office: 61025 montelabbate (pu) italy • via pantanelli, 164 phone +39 0721 90791 15 linee telefax. +39 0721 9079299 (italy) - +39 0721 9079279 (export) email: italia@radiant.It • tecnico@radiant.It • export@radiant.It internet: h...