Controls consist of individual channel gain adjustments. Nominal operating levels are 0 dBm input and +10
dBm output. Higher operating levels can cut dynamic range by operating too close to the clipping point. Adjust each
output to the desired level, keeping clipping in mind.
The input stage has a built-in 6 dB pad. This is used to increase input overload capabilities. For low level signals
where additional gain is required, remove R7, which is mounted on terminal posts. See the PC layout for exact
position.
To disconnect circuit (signal) ground from chassis ground, cut the jumper, marked J on the PC layout, located