Radionics D7024 Reference Manual

Other manuals for D7024: Operating Instructions
Manual is about: Fire control/communicator

Summary of D7024

  • Page 1

    © 1997 radionics, inc., salinas, ca, u.S.A. All rights reserved. ™ the radionics logo is a registered trademark of radionics, inc., salinas ca, u.S.A. D7024 reference guide p/n 31499b reference guide for the d7024 control/communicator radionics, inc., 1800 abbott street salinas, ca 93901, u.S.A. Cus...

  • Page 2: Table of Contents

    Page 2 copyright © 1997 radionics, inc. D7024 reference guide table of contents notices 3 fcc compliance notice 3 fcc phone connection to users 3 notice 3 1.0 overview 4 1.1 system overview 4 1.2 specifications 4 1.2.1 enclosure housing 4 1.2.2 temperature 4 1.2.3 power 4 1.2.4 outputs 4 1.2.5 zones...

  • Page 3: Notices

    D7024 reference guide copyright © 1997 radionics, inc. Page 3 fcc compliance notice this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interf...

  • Page 4: 1.0  Overview

    Page 4 copyright © 1997 radionics, inc. D7024 reference guide 1.0 overview 1.1 system overview the d7024 control/communicator is a fully integrated hard-wire fire alarm system. It can support 4 input points (expandable to 8) and 16 individual users. The control panel has a built-in lcd keypad, howev...

  • Page 5: 1.0  Overview (Continued)

    D7024 reference guide copyright © 1997 radionics, inc. Page 5 1.0 overview (continued) 1.2.6 keypads • maximum # of keypads: 4 d7033 keypads • maximum wire length each: 1000 feet • maximum wire length total: 4000 feet in system • wire type: 4 conductor, unshielded, #22 awg (0.8 mm) “telephone quad” ...

  • Page 6: 2.0  Enclosure Installation

    Page 6 copyright © 1997 radionics, inc. D7024 reference guide 2.0 enclosure installation the d7024 control/communicator and the enclosure are shipped together. The control, however, still needs to be installed into the enclosre. Hardware for mounting the enclosure to a wall, and the control to the e...

  • Page 7

    D7024 reference guide copyright © 1997 radionics, inc. Page 7 3.0 control terminal wiring.

  • Page 8: 4.0  System Worksheet

    Page 8 copyright © 1997 radionics, inc. D7024 reference guide 4.0 system worksheet account numbe r_______________information name_______________________________________ contact person___________________________________ address_____________________________________ voice phone number__________________...

  • Page 9

    D7024 reference guide copyright © 1997 radionics, inc. Page 9 4.0 system worksheet (continued) personal identification numbers example pin number authority level name user 00 1001 3 henry m. Jones pin number authority level name user 00 user 01 user 02 user 03 user 04 user 05 user 06 user 07 user 08...

  • Page 10

    Page 10 copyright © 1997 radionics, inc. D7024 reference guide 4.0 system worksheet (continued) ke ypad location keypad #1 __________________________________________ keypad #2 __________________________________________ keypad #3 __________________________________________ keypad #4 __________________...

  • Page 11: 5.0  Operating Guide

    D7024 reference guide copyright © 1997 radionics, inc. Page 11 5.0 operating guide 5.1 understanding the built-in keypad the keypad built-in to the control/communicator is an alpha-numeric lcd keypad. It has a two line by 16 character display to provide information on various control panel functions...

  • Page 12

    Page 12 copyright © 1997 radionics, inc. D7024 reference guide 5.0 operating guide (continued) 5.3 system operation 5.3.1 modes of system operation there are three modes of system operation for the d7024 control/communicator: • normal operation: when the system is operating normally, it displays “sy...

  • Page 13

    D7024 reference guide copyright © 1997 radionics, inc. Page 13 5.0 operating guide (continued) • zone 60: no ac - active when ac power fails. • zone 59: alarm verification - active while alarm verification is in progress, starting with the first detection of an alarm to be verified and clearing at t...

  • Page 14

    Page 14 copyright © 1997 radionics, inc. D7024 reference guide 5.0 operating guide (continued) 5.6.1 if installed in family residences adherence to nfpa standard 72 can lead to reasonable fire safety when the following items are practiced: • minimize hazards: avoid the three traditional fire killers...

  • Page 15

    D7024 reference guide copyright © 1997 radionics, inc. Page 15 5.0 operating guide (continued) 5.7 personal identification numbers the personal identification number (pin) is the 4 digit code users enter at the keypad to gain access to the system. A pin may be assigned to each user number 00 - 15. T...

  • Page 16

    Page 16 copyright © 1997 radionics, inc. D7024 reference guide • dial out for downloading: the control panel will dial out to the remote programmer. This test requires that phone number 3 (computer) and account code 1 be programmed. • test battery/nac circuits: if a power failure occurs, your contro...

  • Page 17: 6.0  How to Program

    D7024 reference guide copyright © 1997 radionics, inc. Page 17 6.0 how to program the keypad will (under normal conditions) display "system normal" on the top line and, "select:" on the bottom line, followed by the following scrolling menu items: • prog/0 • cmnd/# • test • history • disable • drill ...

  • Page 18

    Page 18 copyright © 1997 radionics, inc. D7024 reference guide 6.0 how to program (continued) 6.1 alpha programming when programming the point descriptions (4- prog inputs / 1- point number / 4- description), the numeric keys are used to enter alpha-numeric information similar to the way telephone b...

  • Page 19

    D7024 reference guide copyright © 1997 radionics, inc. Page 19 7.0 programming menu tree (prog/0) for defaults, see page 24 select: prog/0 cmnd/# test history disable drill 1- prog time 2- security 3- prog system 4- prog inputs 1- system mmddyy hhmm 2- auto test 1- test time: time of day the automat...

  • Page 20

    Page 20 copyright © 1997 radionics, inc. D7024 reference guide select: prog/0 cmnd/# test history disable drill 5- prog outputs 6- prog accounts 7- prog formats 8- history defaults 1- nacs 1- nac #1 1- autosilence?: the nac will silence itself after a specified time period. The system will remain in...

  • Page 21

    D7024 reference guide copyright © 1997 radionics, inc. Page 21 8.0 menu tree (cmnd#, test, history, disable, drill) select: prog/0 cmnd/# test history disable drill 0- prog modes 1- walk test 7- back 1- disable same as 1- short active to end 2- long active to end 3- no activate to end 1- inputs 1- a...

  • Page 22

    Page 22 copyright © 1997 radionics, inc. D7024 reference guide 9.0 installation guide for u.L. Listed systems 9.1 d7024 u.L. Listings the d7024 is u.L. Listed for the following: • commercial fire alarm (type service: local, central station, and remote station; type initiating: automatic, manual, spr...

  • Page 23

    D7024 reference guide copyright © 1997 radionics, inc. Page 23 appendix a: abbreviations on panel display 3/1 = 3/1 tone burst (reporting format) 4/2 = 4/2 tone burst (reporting format) 7035 = d7035 remote relay board @ = option bus address (1 - 16) actvtn = activation a, alrm = alarm alt = alternat...

  • Page 24

    Page 24 copyright © 1997 radionics, inc. D7024 reference guide appendix b: defaults for prog/0 select: prog/0 cmnd/# test history disable drill 1- prog time 2- security 3- prog system 4- prog inputs 1- system last date in ee 0000 2- auto test 1- test time: 0200 2- test freq: 24 hours 1- pins 1- prog...

  • Page 25

    D7024 reference guide copyright © 1997 radionics, inc. Page 25 appendix b: defaults for prog/0 (continued) select: prog/0 cmnd/# test history disable drill 5- prog outputs 6- prog accounts 7- prog formats 8- history defaults 1- nacs 1- nac #1 1- autosilence?: yes 2- configuration: pulsing 3- zone as...

  • Page 26: Index

    Page 26 copyright © 1997 radionics, inc. D7024 reference guide symbols 2-wire circuits 4 4/2 18, 20, 25 a abbreviations 23 alarm operation 12 alpha-numeric lcd keypad 11 alpha programming 18 authority level 15 auxiliary power 4 b backlight control 11 backup battery calculation 5 battery, test 16 bfs...

  • Page 27: Index (Continued)

    D7024 reference guide copyright © 1997 radionics, inc. Page 27 r relays, local 4 remote program dial-out and answer 16 remote relay module 4 required current for alarm 4 response time 4 reversing modules 22 s sia 18, 20, 25 standby battery capacity 5 standby current 4 standby current load 5 supervis...

  • Page 28

    ™ the radionics logo is a registered trademark of radionics, inc., salinas, ca, u.S.A. ©1997 radionics, inc., salinas, ca, u.S.A. All rights reserved radionics, inc., 1800 abbott street salinas, california 93901 customer service: (800) 538-5807.