RadonAway HS Series Installation & Operating Instructions Manual

Summary of HS Series

  • Page 1

    The world’s leading radon fan manufaturer hs series installation & operating instructions radonaway 3 saber way ward hill, ma 01835 www.Radonaway.Com p/n in007-rev j 9 /1 3.

  • Page 2: Hs Series Fan Installation

    Page 2 of 8 in007 rev j radonaway ward hill, ma. Hs series fan installation & operating instructions please read and save these instructions. Do not connect power supply until fan is completely installed. Make sure electrical service to fan is locked in "off" position. Disconnect power before servic...

  • Page 3

    Page 3 of 8 in007 rev j installation & operating instructions (rev j ) for high suction series hs2000 p/n 23004-1 hs3000 p/n 23004-2 hs5000 p/n 23004-3 1.0 system design considerations 1.1 introduction the hs series fan is intended for use by trained, certified/licensed, professional radon mitigator...

  • Page 4

    Page 4 of 8 in007 rev j 1.4 ground water under no circumstances should water be allowed to be drawn into the inlet of the hs series fan as this may result in damage to the unit. The hs series fan should be mounted at least 5 feet above the slab penetration to minimize the risk of filling the hs seri...

  • Page 5

    Page 5 of 8 in007 rev j 1.6 system monitor and label a properly designed system should incorporate a "system on" indicator for affirmation of system operation. A magnehelic pressure gauge is recommended for this purpose. The indicator should be mounted at least 5 feet above the slab penetration to m...

  • Page 6

    Page 6 of 8 in007 rev j 2.0 installation 2.1 mounting mount the hs series fan to the wall studs, or similar structure, in the selected location with (4) 1/4" x 1 1/2" lag screws (not provided). Insure the hs series fan is both plumb and level. 2.2 ducting connections make final ducting connection to...

  • Page 7

    Page 7 of 8 in007 rev j addendum product specifications *power consumption varies with actual load conditions inlet: 3.0" pvc outlet: 2.0" pvc mounting: brackets for vertical mount weight: approximately 18 lbs. Size: approximately 15"w x 13"h x 8"d minimum recommended inlet ducting (greater diameter...

  • Page 8

    Page 8 of 8 in007 rev j important instructions to installer inspect the hs series fan for shipping damage within 15 days of receipt. Notify radonaway of any damages immediately . Radonaway is not responsible for damages incurred during shipping. However, for your benefit, radonaway does insure shipm...