  • Page 1

    Railking gg-1 electric engine operating instructions thank you for purchasing the railking gg-1 electric engine. This railking electric engine contains state-of-the-art electronics with many built-in automatic features for incredibly realistic operation. Despite these advanced features, the locomoti...

  • Page 2

    2 railking gg-1 electric engine table of contents initial lubrication 3 basic operation 3 throttle 3 operation buttons 3 volume control 4 proto-sound 2.0 operation 4 activating proto-sound 2.0 conventional mode features 4 passenger station announcements (psa) 5 tips on using psa 6 proto-coupler ® op...

  • Page 3: Initial Lubrication

    3 railking gg-1 electric engine initial lubrication although the engine was lubricated at the factory, it is important that you lubricate the chassis before operation. Lightly grease the outside idler and drive gears (marked “g” in fig. 3 on page 10) to prevent them from squeaking. Use light househo...

  • Page 4: Proto-Sound

    4 railking gg-1 electric engine proto-sound 2.0 operating instructions because proto-sound 2.0 is an all-new system developed by m.T.H.’s own research and development team, it operates differently from original proto-sound. Most proto-sound 2.0 features are automatically enabled, and the reset state...

  • Page 5

    5 railking gg-1 electric engine passenger station announcements (psa): your engine is equipped with a sound package of passenger station announcements that you can play when you pull into a passenger station. Each sequence described below will play as long as it is left on, randomly generating sound...

  • Page 6: Tips On Using Psas

    6 railking gg-1 electric engine tips on using psas you can terminate psa at anytime by turning off power to the track for 15 seconds. You do not have to be in forward to use psa. At the conclusion of the full sequence, the train will pull away from the station in whatever direction you were going wh...

  • Page 7: Proto-Coupler® Operation

    7 railking gg-1 electric engine proto-coupler® operation this locomotive is equipped with a coil-wound proto-coupler for remote uncoupling action. Because the proto-coupler is controlled through the proto-sound 2.0 microprocessor, it does not require an uncoupling track section or modification to yo...

  • Page 8: Reset to Factory Defaults:

    8 railking gg-1 electric engine lock into a directional state: you can lock your engine into a directional state (forward, neutral, or reverse) so that it will not change directions. To do this, put the engine into the direction you want or into neutral. To lock it into forward or reverse, run it at...

  • Page 9: Maintenance

    9 railking gg-1 electric engine maintenance lubrication and greasing instructions the engine should be well oiled and greased in order to run properly. You should regularly lubricate the pickup rollers to prevent them from squeaking. Use light household oil and follow the lubrication points marked “...

  • Page 10

    10 railking gg-1 electric engine 6. Once the motor mount screw has been removed, pull the motor away from the truck block and lightly coat the motor worm gear and bronze drive gear (in the truck block) with grease. 7. Reassemble the truck and motor, being careful not to pinch any wires between the t...

  • Page 11

    11 railking gg-1 electric engine traction tire replacement instructions your locomotive is equipped with two neoprene rubber traction tires on each powered truck block. While these tires are extremely durable, you may need to replace them at some point. Replace the tires on only one end of the engin...

  • Page 12

    12 railking gg-1 electric engine to replace the tire: 1. Make sure the old tire has been completely removed from the groove in the drive wheel, using a razor blade or small flathead screwdriver to pry away any remains. 2. Slip the new tire onto the wheel. You may find it useful to use two small flat...

  • Page 13

    13 railking gg-1 electric engine light bulbs are located on both ends of the locomotive. Figure 5. Locate the burned-out lightbulbs in the locomotive. To replace the bulb, turn the bulb counter-clockwise to remove and install a new one by reversing the process locomotive light bulb replacement to re...

  • Page 14

    14 railking gg-1 electric engine unhook wires, remove and replace battery battery port figure 6. Unhook the battery leads, remove the battery and replace with a new one. Self-charging battery back-up the special nicad 7-cell 8.4v self-charging battery in this engine improves performance at any speed...

  • Page 15: 2.0 Problems

    15 railking gg-1 electric engine troubleshooting proto-sound ® 2.0 problems although proto-sound 2.0 has been designed and engineered for ease of use, you may have some questions during initial operation. The following table should answer most questions. If your problem cannot be resolved with this ...

  • Page 16

    16 railking gg-1 electric engine cab chatter lock-out volume battery psa remedy remedy remedy remedy remedy sometimes the cab chatter sounds don’t play. I can’t get the engine to run after i power up the transformer. It sits still with the engine sounds running. The engine won’t lock into forward, n...

  • Page 17: Compatibility

    17 railking gg-1 electric engine psa remedy once in psa, the engine doesn’t go into reverse. When the psa enters its last sequence the bell automatically comes on. When psa is enabled, pressing the whistle and bell buttons has no effect. I push the direction button but the next sound clip in the seq...

  • Page 18

    18 railking gg-1 electric engine transformer compatibility and wiring chart note that many of the operational commands described in these instructions require a bell button, so if your transformer does not have its own bell button, you should consider adding one to get the full benefit of the system...

  • Page 19: Control System:

    19 railking gg-1 electric engine additional features accessible with the dcs remote control system: while conventional mode operation of a proto-sound 2.0 engine yields wonderfully realistic sound and several train control features, command mode operation allows the user to access a world of command...

  • Page 20

    20 railking gg-1 electric engine • direction control set up-user can set initial individual start-up direction (start in forward or reverse) for double-heading operations. • locomotive consist set-up-user can determine locomotive values for consist make-ups, allowing multiple locomotives belonging t...

  • Page 21: Participating N.A.S.C.

    21 railking gg-1 electric engine canada california colorado connecticut florida maryland michigan new hampshire new york ohio pennsylvania virginia wisconsin toy train workshop cumberland 613-833-8331 the train room fergus 519-787-3280 tin plate junction oakland 510-444-4780 mizell trains inc westmi...

  • Page 22: Participating A.S.C.

    22 railking gg-1 electric engine canada alabama arizona california colorado connecticut florida illinois indiana iowa kentucky louisiana toy train workshop cumberland 613-833-8331 the train room ergus 519-787-3280 credit valley railway company streetsville 905-826-1306 b h trains terrebonne 450-492-...

  • Page 23

    23 railking gg-1 electric engine maine maryland massachusetts michigan missouri nevada new hampshire new jersey new york north carolina ohio wheels, wings & things ludlow 207-532-6277 plaza hobby cumberland 301-729-6424 hobbytown u s a frederick 301-694-7395 engine house hobbies gaithersburg 301-590...

  • Page 24

    Trains-n- things north canton 330-499-1666 grand pacific junction olmstead falls 440-235-4777 rick's toy trains toledo 419-478-0171 erie railway depot troy 937-440-9972 american hobby center aliquippa 724-378-3930 allentown toy train service allentown 610-821-0740 on the right track altoona 814-942-...

  • Page 25: Limited One-Year Warranty

    25 railking gg-1 electric engine service & warranty information limited one-year warranty how to get service under the terms of the limited one-year warranty when you suspect an item is defective, please check the operator's manual for standard operation and trouble-shooting techniques that may corr...