- DL manuals
- Rain Bird
- Controller
- E-6C
- User Manual
Rain Bird E-6C User Manual
Summary of E-6C
Page 1
G b f e español ...................................................................... 29 français ...................................................................... 57 english........................................2.
Page 2
2 ec controller ec controller icon legend off auto date/time manual station(s) day cycle water day program start time station run time water budget manual cycle test preset schedules + - program button enter set month set day set time.
Page 3
3 ec controller contents introduction ........................................................... 4 ec controller ................................................................. 4 controller stations......................................................... 5 what is a program? .......................
Page 4
4 ec controller warning: a circuit breaker or cutoff switch is to be provided in the fixed wiring to isolate the controller. Memory is retained by a battery which is to be disposed of in accordance with local regula- tions. Caution icons the lightning flash with arrowhead symbol, within an equilater...
Page 5
5 ec controller you will need to understand the following terms to successfully program your ec controller. • watering day cycle the period of days in which the controller repeats the program you set. For example, a 7-day cycle is a weekly schedule that repeats once every seven days. A 2-day cycle...
Page 6
6 ec controller controller basics programming under battery power if you wish, you can program the controller under battery power. This feature can be useful if the controller is installed in an area that is not readily accessible. This feature also allows you to enter program information before ins...
Page 7
7 ec controller every three seconds, the lcd displays the problem stations number and the letters err. the controller will continue to run each operable station in the program. As each station is running, the controller (at an alternate 3-second interval) displays the working stations number and...
Page 8
8 ec controller programming checklist to program your ec controller for the first time, we recommend that you complete the steps in the order listed to the right. ❒ fill out the programming chart ....................... P. 8 ❒ erase any existing programming ..................... P. 12 ❒ set the curr...
Page 9
9 ec controller.
Page 10
10 ec controller • od31 = waters only on odd-numbered days of the month, but not on the 31st of any month or on february 29. (this watering day cycle complies with special ordinances in some water-restricted areas). 4. In the program start times box for program a, write the time you want the program...
Page 11
11 ec controller.
Page 12
12 ec controller programming the controller erase any existing programming diagram 5 after you finish filling out the programming chart, you are ready to begin programming the controller. When you program the controller for the first time, it is a good idea to use the program erase feature to erase ...
Page 13
13 ec controller note: in 230 v models, the first flashing 01 represents the day. You will set the day first, and then the current month. 4. Press enter. 5. The second 01 begins flashing (representing the day of the month). A cursor will appear under the set day icon. 6. Press + or - to set the ...
Page 14
14 ec controller select program (a, b, and/or c) diagram 10 1. Turn the programming dial to day cycle. 2. The letter of the currently selected program (a, b, or c) appears in the display. 3. Press the program button until the desired program (a, b, or c) appears in the display. Remember, if you plan...
Page 15
15 ec controller • 7-day (custom) waters on a weekly cycle; any day of the week can be a watering day. • ev waters only on even-numbered days. • od waters only on odd-numbered days. • od31 waters only on odd-numbered days, except the 31st of any month and february 29th. 3. If you select a 7-...
Page 16
16 ec controller 5. Press + or - to move todays position in the watering cycle. Set program start time(s) diagram 14 1. Turn the programming dial to prgm start time. 2. The program letter (a, b, or c), the number 1 (indicating the earliest start time), and a row of four dashes ... appear in...
Page 17
17 ec controller set station run times diagram 16 1. Turn the programming dial to station run time. 2. The program letter (a, b, or c), the number 1 (indicating the station number), and 0 00 appear in the display. 3. Press + or - to set the run time for station number 1. You can set a station to...
Page 18
18 ec controller adjust water budget diagram 20 & 21 adjusting the water budget feature is the easiest way to increase or decrease the run times of all stations on a program. You can use water budget to decrease watering during cool winter months, or to increase watering during hot, dry periods. You...
Page 19
19 ec controller 3. Press + to increase the water budget percentage, or press - to decrease the water budget percentage. 4. When the water budget percentage is set to any figure other than 100, all programs (a, b, and c) display a percent sign (%) in front of the program letter. 5. After setting the...
Page 20
20 ec controller manually run a program diagram 24 1. Turn the programming dial to manual cycle. 2. Program a appears in the display. 3. To choose another program, press the program button (abc) until the desired program letter appears in the display. 4. Press enter to start the selected program. No...
Page 21
21 ec controller note: if you want to test only one (or more) stations, follow the procedure in manually run a station(s) on p. 19. 2. The number 2 appears in the display, representing a two- minute test run per station. 3. Press + or - to increase or decrease the test run time. You can set the ...
Page 22
22 ec controller caution: to avoid electrical shock, do not plug in the transformer until you have connected it to the controller. To connect the transformer cable to the terminal strip in the controller cabinet: 1. Make sure the transformer is not plugged in. 2. Plug the snap-on connector on the tr...
Page 23
23 ec controller 5. That completes the mounting and wiring procedures for your ec controller. Replace the lower access cover on the controller, and you are ready to begin programming. Refer to programming the controller on p. 12. This illustration shows the various wire runs and connections betwee...
Page 24
24 ec controller troubleshooting lcd display is blank. 1. Power is off to the controller. Re-establish power to the controller. If the current time is not shown, or your program is no longer in memory, reprogram the controller. 2. If under battery power, the controller may be in sleep mode. Press ...
Page 25
25 ec controller symptom possible cause correction program does not begin watering as scheduled. 5. Programming dial is set to the off position. Set the programming dial to auto. 6. Start time has not been properly entered for the program. Turn the dial to prgm start time and check the start times e...
Page 26
26 ec controller 11. A start time has not been entered for the stations assigned program. Turn the dial to prgm start time and check the start times entered for the program. If the stations start time is missing, enter it as described on p.16. Watering starts when it should not. 12. An unwanted pr...
Page 27
27 ec controller lcd display shows err. 15. The automatic circuit breaker has detected an electrical problem. The err in the display indicates a short circuit or electrical overload on a particular station. The stations number should also be displayed. For example, 2 err means the problem is ...
Page 28
28 ec controller notes.