Rain Bird Optima PRT-4 Owner's manual - Legend:

Manual is about: AUTOMATIC SPRINKLER TIMER

Summary of Optima PRT-4

  • Page 1

    1 automatic sprinkler timer owner’s manual prt-4 / prt-6 for use with standard 24 vac automatic sprinkler valves. These timers are designed for use in any 110 vac /60 hz ±10% ac outlet (240 vac, 50 hz for international version). The prt sprinkler series timers provide simple programming and flexible...

  • Page 2: Special Upgrade Offer

    Special upgrade offer save an extra 15% off new sprinkler timers and irrigation controllers at the rain bird online store.* enter discount code: upgrade15 at checkout to save an extra 15% off* * additional discount not valid on clearance items, bundles or store specials. Discount applies to controll...

  • Page 3: Legend:

    2 watering schedule (days) you can choose how often to water your lawn in one of three ways: 1) by specific days of the week (mo, tu, we, etc.), 2) by day intervals (every day, every 2 days or every 3 days), or 3) by a choice of mo, we and fr or tu, th and sa. A schedule of specific days of the week...

  • Page 4

    3 step 1: choose timer location select an indoor location near a standard 120 volt ac electrical outlet (240 volt outlet for 50 hz units). The location should be completely protected from moisture, direct sunlight and below freezing temperatures. (important: do not plug in the transformer until you ...

  • Page 5

    4 connect the one common wire (usually the white strand) to the terminal labeled "com". Connect the second "hot" wire (usually the color-coded strand) from each valve to one of the terminals numbered 1 -6 on the number of stations on your timer model. Connect wire from valve 1 to terminal 1, valve 2...

  • Page 6

    5 step 5: connect transformer 1. Turn dial to off. Note: in off position display will be blank. 2. Plug pigtail connector (located at the end of transformer wire) into the two prongs to the left of the battery holder located under the cover of the timer. 3. Plug transformer into electrical socket. 4...

  • Page 7

    6 programming the prt-4 / prt-6 day/clock su mo tu we th fr sa am indicator symbol step 2: set the watering days when shipped from the factory the timer has a default program with an 8 a.M. Start time once a day, everyday. When setting the days to water, you can select specific days of the week (i.E...

  • Page 8

    7 5. Press the Û button to confirm the program. The lights and display will be on steady to show how the program is set. 6. Rotate the dial to auto make sure there is not a sym- bol showing under the skip, mo, we, fr, or tu, th, sa position. If there is an indicator symbol under any of the above men...

  • Page 9

    8 step 3: set the watering start times when shipped from the factory the timer has a default program with an 8 a.M. Start time once a day. 1. Turn the dial to the start time position. 2. At this point the "a" indicator symbol will be on, and the start time will be displayed (default is 8:00 a.M.). T...

  • Page 10

    9 4.At this point the next zone indicator symbol will be on and the amount of time for that zone will be flashing. Press the Ý or Þ arrow to adjust the time to the cor- rect amount of time. 5.Press the Û button to move to the next zone and re- peat step 4 for the remainder of the zones or turn the d...

  • Page 11

    10 maintaining your system (continued) 2.Battery back-up we recommend that you replace your battery every year at the same time you change your fire alarm battery. If frequent power outages occur, you may need to replace the battery more frequently. Need help? Call toll-free: 1 (800) 742-9922 (u.S.A...