Rainbow 12V Instruction Manual - page 2
Load eg DC Light
Please Note: This sensor can work from
either 12 Volts DC or 12 Volts AC. Hence the
power (red) and load (blue) internal wires are
not marked for polarity.
2. Installing Your Motion Sensor
Caution: turn off all power by removing power fuse or turning off circuit breaker.
-
Read entire instruction manual before proceeding.
-
All wiring should comply with local electrical codes and may require a qualified electrician.
-
The total lighting load connected to the Sensor must not exceed 10A load. Do not use to control motors
or pumps.
-
If you are replacing an existing outdoor light, turn off the power, disconnect and remove the old fixture.
Install Procedure
1. Fasten the box base rigidly to the selected mounting surface (Wall or Ceiling) with the cable entry hole
facing downward. (see FIG A)
2. Take Light & Power Cable through rubber grommet, thenconnect wires as per wiring diagram.
(see FIG C)
3. Knock out either of the holes for fitting the sensor onto the base (depending on whether it will be wall
mounted or ceiling mounted). (FIG D).
4. Fit terminal block onto pins and install the sensor, securing it onto the connection box with the plastic
washer and metal nut provided.
5. Re-check if the wire connection is correct.
6. Cover base with sensor cover, then fix with 2 screws.