RainSoft UF50T-CBVOC Owner's Manual - Operational Specifications
4
Operational Specifications
Working Pressure
40 psi _ 100 psi (275 kPa _ 689 kPa)
Operating Temperatures
50°F _ 100°F (10°C _ 38°C)
pH Range
2 _ 11
Maximum TDS Level
1400 parts per million
Maximum Turbidity Influent Level
11 NTU (nephelometric turbidity units)
Maximum Hardness Level
5 grains
Capacity for VOC Reduction
Models UF50T-CBVOC and UF50N-CBVOC: 100 gallons (378 liters)
Additional Specifications
• The inlet water should be free from iron, manganese, and sulfur.
• This system has been tested for the treatment of water containing
pentavalent arsenic (also known as AS (V), As (+5), or arsenate) at
concentrations of 0.30 mg/L or less. This system reduces pentavalent
arsenic, but may not remove other forms of arsenic. This system is to
be used on water containing a detectable free chlorine residual or on
water supplies that have been demonstrated to contain only pentavalent
arsenic. Treatment with chloramine (combined chlorine) is not suffi-
cient to ensure complete conversion of trivalent arsenic to pentavalent
arsenic. Please see the Arsenic Facts section of the performance data
sheets for further information.
• Do not use this product with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
• This system must be installed in accordance with all applicable state
and local laws and regulations.
• This system must be installed in an area not affected by extreme heat,
cold or the elements. The selected installation area must be adequate
for easy service of all parts.
• This system is designed to treat cold water only. The installation must
be on a cold water supply.
Data Chart
Items Required for Installation
Tools:
Drill, drill bits, tube cutter, screwdrivers, adjustable wrench, and
vinyl gloves.
Parts:
RainSoft faucet, inlet shut off valve, 1/4 inch O.D. tubing, 3/8 inch
O.D. tubing, and screws.
!
Important Note: This Reverse Osmosis System
contains replaceable treatment components,
critical for the effective reduction of total
dissolved solids (TDS). The product water
should be tested periodically to verify that the
system is performing properly. See your local
RainSoft Dealer for details.
Model
Daily
Production Rates
Efficiency Rating*
Recovery Rating*
UF22T-CB, UF 22N-CB
8.45 gpd/31.98 L/day
10.58%
24.54%
UF50T-CBVOC, UF50N-CBVOC 15.35 gpd/58.10 L/day
7.79%
15.13%
!
Important Note: If the hardness is greater than
5 grains, the system will still perform properly,
but the longevity of the membrane may be
affected.
!
Important Notes: The installation location of
the system must be determined before
purchasing a faucet. If you are mounting the
system under a kitchen sink, an air gap faucet
will be required. If you are mounting the
system in a different location, a non-air gap
faucet will be required, along with a separate
air gap device.
The tubing used for installation must be of
food grade type. John Guest or Parker brand
tubing is recommended for their compatibility
with the fittings on your system.
The efficiency and recovery ratings are verified
by testing in accordance with NSF/ANSI
Standard 58.
Efficiency rating means the percentage of the
influent water to the system that is available to
the user as reverse osmosis treated water
under operating conditions that approximate
typical daily usage.
Recovery rating means the percentage of the
influent water to the membrane portion of the
system that is available to the user as reverse
osmosis treated water when the system is
operated without a storage tank or when the
storage tank is bypassed.
*