- DL manuals
- RainSoft
- Water Filtration Systems
- Ultrefiner II
- User Manual
RainSoft Ultrefiner II User Manual - Lista De Piezas
39
Ítem #
Pieza #
Cantidad
Descripción
1
51570
1
CONJUNTO DESAGÜE 1/4 & TANQUE 3/8 UF II
2
51571
1
CONJUNTO DE ENTRADA TAPA DE CONTENEDOR 1/4 UF II
3
51572
1
CONJUNTO SALIDA TAPA DE CONTENEDOR 3/8
4
51561
2
ARANDELA UF II
5
19914
2
JUNTA TÓRICA -013
6
19621
2
JUNTA TÓRICA 3/8
7
71497
4
TORNILLO #10-16 x 1 pulg. (15-222)
8
51567
6
TORNILLO CABEZA PLANA 8-16 x 3/4 SS
9
12994
4
JUNTA TÓRICA 237 -9516
10
51605
3
CONTENEDOR UF II, SLIM LINE MOTAS GRISES
11
12632
1
JUNTA TÓRICA 029
12
17360
1
CARTUCHO DE CIERRE DEL DESAGÜE
13
19899
1
TAPA DE CIERRE UF II
14
19897
1
UF II CILINDRO DE DRENAJE
15
10102
1
RETENEDOR DE VÁLVULA DE DRENAJE
16
51630
1
JUNTA TÓRICA 2MM x 16MM EPR 70 D
17
17958
1
JUNTA TÓRICA 015
18
19898
1
SELLO DE CILINDRO DE DRENAJE UF II
19
71961
1
BOLA DE ESTRANGULACIÓN
20
51562
1
JUNTA TÓRICA 008
21
51560
1
ENCHUFE DE BOLA DE RETENCIÓN UF II
22*
51631
1
ATADURA REBORDEADA LIBERABLE NEGRA
23
51741
1
CONJUNTO DE LA TAPA UF II
24
17034
1
VÁLVULA DE BOLA NPT TUBO 3/8 x 1/4“
25
51640
1
CONJUNTO DEL TANQUE DE ALMACENAMIENTO UF II
26
51635
1
REEMPLAZO PREFILTRO DE CARBÓN UF II / NEGRO
27
51636
1
REEMPLAZO POSTFILTRO DE COV DE CARBÓN UF II / BLANCO
28
51637
1
REEMPLAZO MEMBRANA 50 GPD UF II
29 *
51614
1
CONTROL DE FLUJO 1.0 GPM UF II
30 *
19005
3
CLIP DE FIJACIÓN 3/8 pulg.
31 *
19006
2
CLIP DE FIJACIÓN 1/4 pulg.
Lista de Piezas
*Puede encontrar el ítem nº 22, 29, 30 y 31 en el paquete de garantía.
Summary of Ultrefiner II
Page 1
Rainsoft division of aquion, inc 2080 east lunt avenue elk grove village, illinois, 60007 1.847.437.9400 or 1.800.860.7638 www.Rainsoft.Com ™ this product is manufactured in an iso 9001: 2008 certified facility. Model ultrefiner ii - fmv - bnfp, ultrefiner ii - fmv - bnfv, ultrefiner ii - fmv - chfp...
Page 2: Table of Contents
2 table of contents product information .................................................................................... 3 product certification information.............................................................. 4 components requiring periodic replacement ....................................
Page 3: Product Information
Product information your rainsoft ultrefiner ii system provides several stages of treatment to provide you with the best possible drinking water. The components of the system are: pre-filter the pre-filter is a combination carbon/sediment filter. It removes most suspended solids 10 microns or larger...
Page 4: Replacement
4 product certification information models ultrefiner ii-fmv-bnfp, ultrefiner ii-fmv-bnfv, ultrefiner ii-fmv-chfp and ultrefiner ii-fmv-chfv conform to nsf/ansi 58 for the specific performance claims as verified and substantiated by test data. See performance data sheets for specific reduction claim...
Page 5: Operational Specifications
* operational specifications working pressure 40 psi _ 100 psi (275 kpa _ 689 kpa) operating temperatures 50°f _ 100°f (10°c _ 38°c) ph range 2 _ 11 maximum tds level 1400 parts per million (ppm) maximum turbidity influent level 11 ntu (nephelometric turbidity units) maximum hardness level 5 grains ...
Page 6: Installation Location
6 items required for installation tools: drill, drill bits, screwdriver, tube cutter, adjustable wrench, phillips offset screwdriver, and vinyl gloves . Parts not included in package: inlet shut off valve, ptfe thread sealant tape, 1/4 inch o.D. Tubing, additional 3/8 inch o.D. Tubing and mounting s...
Page 7: Installation Instructions
Installation instructions 1. Install the filters and membrane cartridge • wearing sterile gloves, remove the two filters and membrane from the sterile packaging and place them in the appropriate housings. • secure filter housings by hand tightening counter clockwise (looking from the top) to ultrefi...
Page 8
2. Mount the system use screws (not supplied) to secure the ultrefiner ii bracket assembly to the 8 10.0 in (25.4 cm) 4.7 in (11.9 cm) without cover 5.0 in (12.7 cm) with cover 7.0 in (17.8 cm) mimimum required from mounted wall for cover on / off 15.1 in (38.4 cm) 12.3 in (31.3 cm) 12.5 in (31.8 cm...
Page 9
9 4. Install the faucet • select a location for the faucet to be mounted. • drill a hole according to the manufacturer’s recommendations. • mount the faucet per instructions. • if using faucet air gap, press drain line tubing onto faucet. • use 3/8 inch tubing (not supplied) to connect the faucet to...
Page 10
7.Connect the drain outlet use 1/4 inch tubing (not supplied) to connect the drain outlet to the appropriate drain connection. 8. Secure the connections attach the red locking clips (supplied) to the connection fittings. 10 use releaseable straps to band together tubing use releasable strap to band ...
Page 11
9. After system start up because the ultrefiner ii bracket assembly and cover are reversible, the cover is designed with removable side panels for tube routing. Choose the correct side panel to remove based on the installation. • remove the side panel by cutting with knife or clippers. • place cover...
Page 12: System Start Up
12 system start up 1. Turn on the water supply allow the system to start filling with water. 2. Fast flush the system open the ultrefiner ii faucet and turn the drain barrel to the fast flush (“f” on the drain barrel)position (see figure 12). 3. Reposition the drain barrel once the air has been purg...
Page 13: Routine System Maintenance
13 7. Complete the installation • if a 24 hour-flush pre-installation is not performed by your local dealer, it is important to open the faucet and let the system run to drain for 24 hours first. • after the 24 hour water flush , close the ultrefiner ii faucet and allow the storage tank to fill with...
Page 14: How to Change The Filters
14 helpful tips: to avoid contamination, we recommend the use of sterile gloves while changing the system components. When changing the membrane cartridge, verify that the rubber brine seal and o-rings are secure and in place. Always lubricate the o- rings with a non-petroleum based lubricant to ens...
Page 15
15 3 11 12 8 4 5 9 10 21 10 10 6 4 5 15 16 17 18 27 28 26 22 31 9 2 20 19 6 9 14 1 7 13 29 24 25 23 30 ultrefiner ii system exploded view and parts list.
Page 16: Parts List
16 parts list item # part # quantity description 1 51570 1 uf ii unibody 1/4 drain & 3/8 tank assembly 2 51571 1 uf ii sump cap 1/4 inlet pre assembly 3 51572 1 uf ii sump cap 3/8 outlet post assembly 4 51561 2 uf ii washer unibody 5 19914 2 o-ring -013 6 19621 2 3/8 o-ring 7 71497 4 screw #10-16 x ...
Page 17
17 17 hole dimension with use of air gap min Ø 15 16 " max Ø 1 " 1 2 air gap out 3 8 " tube to drain connection air gap in 1 4 " tube to uf ii drain connection product water in with 3 8 " tube item # qty aquion part description 1 1 51609 contemp plus b-nickel faucet assy ( includes item # 2) 51624 c...
Page 18: Troubleshooting Guide
18 troubleshooting guide symptom cause solution no water running from outlet 1. Water supply is turned off. 1. Turn on the water. 2. Water supply is blocked 2. Clear blockage. If this does not work blockage could be internal to the ultrefiner ii or external with the water line. Contact your rainsoft...
Page 19: Ultrefiner II - Fmv
19 • automatic drain shut-off valve • ph range: 2 - 11 • manual fast flush valve • replacement filters: • daily production rate = 16.02 gpd description item# • efficiency rating 3 = 17.54% pre filter 51635 • recovery rating 4 = 37.23% membrane 51637 • max tds level (ppm) = 1400 post voc filter 51636...
Page 20: Ultrefiner II - Fmv
20 20 performance data sheet - page 2 of 3 ultrefiner ii - fmv premium drinking water system contaminant influent challenge concentration mg/l maximum permissible product water concentration mg/l usepa mcl (mg/l) alachlor 0.050 0.001 0.002 atrazine 0.100 0.003 0.003 benzene 0.081 0.001 0.005 carbofu...
Page 21: Ultrefiner II - Fmv
21 arsenic facts arsenic (as) is a naturally occurring contaminant found in many ground waters. It generally occurs in two forms (valences or oxidation states): pentavalent arsenic (also know as as(v), as(+5), or arsenate) and trivalent arsenic (also know as as(iii), as(+3), or arsenite). In natural...
Page 22
22 limited lifetime warranty for as long as you own the equipment rainsoft division of aquion, inc. Believing its ultrefiner ii premium drinking water system to be of exceptional quality, hereby warrants said equipment to its first purchaser at retail as follows: the storage tank housing, filter hou...
Page 23
23 installer specification sheet dealer name: phone number: installation number: installation date: model number: serial number: (see label) line pressure: (psi) hardness: chlorine: ph: inlet tds:.
Page 24
™ rainsoft division of aquion, inc. 2080 east lunt avenue elk grove village, illinois 60007 main switchboard: 1.847.437.9400 customer service: 1.800.860.7638 www.Rainsoft.Com ©2013 rainsoft division of aquion, inc..
Page 25
25 tomando la preocupación fuera del agua desde 1953 sistema de agua potable premium ™ este producto es fabricado en una instalación certificada por iso 9001: 2008 . No aprobado para uso en california. Por favor, solicitar manuales de usuario de productos específicos de california al proveedor rains...
Page 26: Tabla De Contenidos
26 tabla de contenidos información sobre el producto 27 información sobre la certificación del producto .................................... 28 componentes que requieren un reemplazo periódico .......................... 28 especificaciones de operación ..................................................
Page 27
Información sobre el producto su sistema rainsoft ultrefiner ii proporciona varias etapas de tratamiento para proporcionarle la mejor agua potable posible. Los componentes del sistema son: prefiltro el prefiltro es un filtro de combinación de carbono/sedimentos. Elimina la mayoría de los sólidos sus...
Page 28: Producto
Información sobre la certificación del producto los modelos ultrefiner ii - fmv - bnfp, ultrefiner ii - fmv - bnfv, ultrefiner ii - fmv - chfp y ultrefiner ii - fmv - chfv están conformes a la norma nsf / ansi 58 para las afirma- ciones específicas de rendimiento verificadas y sustentadas en datos d...
Page 29
29 especificaciones de operación presión de funcionamiento 40 psi – 100 psi (275 kpa – 689 kpa) temperaturas de funcionamiento 50°f _ 100°f (10°c _ 38°c) rango ph 2 _ 11 nivel máximo de tsd 1400 partes por millón (ppm) nivel máximo de turbidez a la entrada 11 unt (unidades nefelométricas de turbidez...
Page 30
Elementos necesarios para la instalación herramientas: taladro, brocas, destornillador, cortador de tubo, llave inglesa ajustable, destornillador acodado phillips y guantes de vinilo. Partes no proveídas en el paquete : válvula de cierre de entrada, cinta de teflón, tubería de 1/4 pulgadas d. I., tu...
Page 31
Instrucciones de instalación 1 •instalar los filtros y el cartucho filtrante •usando guantes estériles, retirar los dos filtros y la membrana del envase estéril y colocarlos en las carcasas apropiadas. •asegurar las carcasas de los filtros apretando a mano en sentido contrario a las agujas del reloj...
Page 32
2. Montar el sistema • utilizar tornillos (no proveidos) para fijar el conjunto de soportes ultrefiner ii a la ubicación prevista. 3. Instalar el grifo • seleccionar una ubicación para montar el grifo. • taladrar un agujero de acuerdo con las recomendaciones del fabri cante. • montar el grifo según ...
Page 33
4. Instalar la válvula de cierre de entrada (no proveída) • cerrar el suministro de agua fría y abrir el grifo de agua fría para aliviar cualquier presión de línea; • instalar la válvula de cierre de entrada (no proveída) entre la válvula de cierre existente y el grifo de cocina, de manera que cumpl...
Page 34
8. Después del arranque del sistema cómo el conjunto de soportes ultrefiner ii y la tapa son reversibles, la tapa está diseñada con paneles laterales extraíbles para el enrutamiento de la tubería. Elegir el panel lateral correcto para quitar con base en la instalación. • quitar el panel lateral. Usa...
Page 35: Arranque Del Sistema
35 arranque del sistema 1. Abrir el suministro de agua dejar que el sistema comience a llenar con agua. 2. Enjaguar rápidamente el sistema abrir el grifo ultrefiner ii y girar el cilindro de drenaje para la posi- ción de descarga rápida ("f" en el cilindro de drenaje) (ver figura 12).. 3. Reposicion...
Page 36: Pruebas De Su Agua
36 7. Terminar la instalación • si una descarga de 24 horas de preinstalación no es llevada a cabo por su distribuidor local, es importante abrir el grifo y dejar que el sistema funcione para drenar durante 24 horas. • después de la descarga de agua 24 horas, cerrar el grifo ultrefiner ii y permitir...
Page 37: Cómo Cambiar Los Filtros
37 cómo cambiar los filtros 1.Cerrar el suministro de agua fría al sistema ultrefiner ii. 2. Cerrar la válvula de cierre del tanque de almacenamiento y abrir el grifo ultrefiner ii. 3.Colocar una bandeja de goteo o cubeta si necesario para coger el agua de los cartuchos de los filtros, para evitar d...
Page 38
38 3 11 12 8 4 5 9 10 21 10 10 6 4 5 15 16 17 18 27 28 26 22 31 9 2 20 19 6 9 14 1 7 13 29 24 25 23 30 vista despiezada del sistema ultrefiner ii y lista de piezas.
Page 39: Lista De Piezas
39 Ítem # pieza # cantidad descripción 1 51570 1 conjunto desagÜe 1/4 & tanque 3/8 uf ii 2 51571 1 conjunto de entrada tapa de contenedor 1/4 uf ii 3 51572 1 conjunto salida tapa de contenedor 3/8 4 51561 2 arandela uf ii 5 19914 2 junta tÓrica -013 6 19621 2 junta tÓrica 3/8 7 71497 4 tornillo #10-...
Page 40
40 vista despiezada del grifo y lista de piezas dimension del agujero con boquete de aire min Ø 15 16 " max Ø 1 " 1 2 salida de boquete de aire tubo de 3/8" para conexion de drenaje entrada de agua producida con tubo de 3/8" entrada del boquete de aire tubo de 1/4" para conexion de drenaje uf ii . E...
Page 41
41 síntoma causa solución no hay agua corriendo de la salida 1. El suministro de agua está cerrado. 1. Abrir el agua. 2. El suministro de agua está bloqueado. 2. Eliminar la obstrucción. Si esto no funcione, la obstrucción puede ser interna a el ultrefiner ii o externa, en la tubería del agua. Pónga...
Page 42: Ultrefiner II - Fmv
42 hoja de datos de rendimiento - página 1 de 3 ultrefiner ii - fmv sistema de agua potable premium • vÁlvula de cierre de drenaje automÁtica • rango ph: 2 – 11 • vÁlvula de descarga rÁpida manual • filtros de repuesto: • Índice de producciÓn diaria = 16.02 gpd descripciÓn Ítem: • Índice de eficienc...
Page 43: Ultrefiner II - Sfmv
43 ultrefiner ii - sfmv sistema de agua potable premium hoja de datos de rendimiento - página 2 de 3 contaminante concentraciÓn media afluente mg/l concentraciÓn mÁxima admisible en el agua producida (mg/l) lcm ape ee. Uu. (mg/l) alaclor 0.050 0.001 0.002 atrazina 0.100 0.003 0.003 benceno 0.081 0.0...
Page 44: Ultrefiner II - Fmv
44 hoja de datos de rendimiento - página 3 de 3 ultrefiner ii - fmv sistema de agua potable premium hechos acerca de arsÉnico el arsénico (as) es un contaminante natural encontrado en aguas distintas. Por lo general, se produce en dos formas (valen- cias o estados de oxidación): arsénico pentavalent...
Page 45
45 garantía limitada de por vida durante el tiempo que usted posee los equipos rainsoft division de aquion, inc., creyendo que su sistema de agua potable premium ultrefiner ii es de una calidad excepcional, garantiza, por la presente, este equipo a su primer comprador al por menor de la siguiente ma...
Page 46
46 ficha técnica del instalador nombre del distribuidor: número de teléfono: número de la instalación: fecha de instalación: número de modelo: número de serie: (ver etiqueta) presión de línea: : (psi) dureza:: cloro: ph: tsd de entrada:.
Page 47
47 notas.
Page 48
48 ™ rainsoft division of aquion, inc. 2080 east lunt avenue elk grove village, illinois 60007 principal panel de control: 1.847.437.9400 servicio al cliente: 1.800.860.7638 www.Rainsoft.Com ©2013 rainsoft division of aquion, inc..