Summary of GEO

  • Page 1

    English rais - manual for geo 1 u s e r m a n u a l rais geo.

  • Page 2

    W e cannot be held r esponsible for any misprints..

  • Page 3

    English rais - manual for geo 3 rais geo dato: march 2008 modified: 1 introduction .................................................................................................................................. 4 warranty ..............................................................................

  • Page 4

    English rais - manual for geo 4 introduction thank you for purchasing a rais wood burning stove. In the uk the stove has been approved by hetas ltd as an intermittent operating appliance for burning wood logs only. A rais wood burning stove is more than just a heat source: it also shows that you car...

  • Page 5

    English rais - manual for geo 5 rais geo 161 rais geo 126 nominal output (kw): 5 5 min./max. Output(kw): 3-8 3-8 heating ar ea (m 2 ) ca. 100 ca. 100 stove’ s width/depth/height (mm) 490-490-1610 490-490-1260 combustion chamber’ s width/depth/height (mm) 288-288-500 288-288-500 recommended amount of...

  • Page 6

    English rais - manual for geo 6 installation instructions the following pages give instructions for the safe and proper installation of this heating ap- pliance in the uk. These instructions cover the basic principles of installation, although detail may need slight modification to suit particular l...

  • Page 7

    English rais - manual for geo 7 chimney the chimney is the driving force which makes the stove function. In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure the correct draught of 14 to 18 pa so as to clear the products of combustion and prevent problems ...

  • Page 8

    English rais - manual for geo 8 if it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should in its closed position leave a mini...

  • Page 9: Geo

    English rais - manual for geo 9 manufacturer’s plate for geo en 13240:2001+a2:2004 ec.Nr. 806 anordning til intervalfyring produktdokumentation sintef producent afstand til brændbart, bagvæg afstand til brændbart, sidevæg afstand til brændbart, drejefod : co emission røggas temperatur nominel effekt...

  • Page 10: Installation of Soapstone

    English rais - manual for geo 10 installation of soapstone list of materials (individual components for assembling soapstone) item number product designation geo 161 number geo 126 number 8060602grey topplate with knock-out 1 1 8067002 8067001 8067006 8067011 8067012 8067021 8067022 8067031 8067032 ...

  • Page 11

    English rais - manual for geo 11 1. Place the stove where you want to install it (it cannot be moved after the soapstone is installed). A) rear exit can be installed when the third row of soapstone is installed - only geo 161. The distance at the top between the sides of the stove is 250 mm, and fit...

  • Page 12

    English rais - manual for geo 12 5. With fresh-air intake: mount the air supply at the bottom of the stove with a flexi hose and a clamp. Without fresh-air intake: fit the vent grill (see step 5)..

  • Page 13

    English rais - manual for geo 13 mountings (packed with the soapstone) 4 pieces 2 pieces 2 pieces 6 pieces rais geo 161 step 1.

  • Page 14

    English rais - manual for geo 14 step 3 step 2.

  • Page 15

    English rais - manual for geo 15 step 5 step 4.

  • Page 16

    English rais - manual for geo 16 2 pieces 2 pieces 2 pieces 4 pieces rais geo 126 step 1 mountings (packed with the soapstone).

  • Page 17

    English rais - manual for geo 17 step 3 step 2.

  • Page 18

    English rais - manual for geo 18 step 5 step 4.

  • Page 19

    English rais - manual for geo 19 installation distance in case of combustible wall to find out whether the wall next to where the stove is going to be installed is flammable, you should contact your building contractor or the local building authorities. The hearth should be able to accommodate the w...

  • Page 20

    English rais - manual for geo 20 corner set-up 45° a. Distance to furniture 900 mm distance to flammable materials: b. - in front (floor) 300 mm c. - to the side (floor) 150 mm d. - to the rear (wall) 100 mm e. - to the side of the wall 650 mm f. - to the side of the wall(door side) 250 mm.

  • Page 21

    English rais - manual for geo 21 installation distance in case of non-combustible wall we recommend a minimum distance to non-combustible material of 50 mm (f) for clean- ing considerations. It should always be possible to access the accessdoor..

  • Page 22

    English rais - manual for geo 22 for the installer finally before firing the stove for the first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to the chimney. En...

  • Page 23

    English rais - manual for geo 23.

  • Page 24

    English rais - manual for geo 24 operating instructions please note that hetas approval only covers the use of wood in the stove and approval does not cover the use of other fuels either alone or mixed with other fuels, nor does it cover instructions for the use of other fuels. Fuel the stove is des...

  • Page 25

    English rais - manual for geo 25 the following table shows the calorific value of different types of wood, which have been stored for 2 years, and which have a residual moisture of 15-17%. Wood kg dry wood pr. M 3 compared to beech/oak hornbeam 640 110% beech and oak 580 100% ash 570 98% maple 540 9...

  • Page 26

    English rais - manual for geo 26 regulating the combustion air all rais stoves are equipped with a one-handed operating lever for regulating the damp- er. The stove-specific regulating mechanisms can be seen on the diagrams. Primary air is the combustion air added to the primary combustion zone, i.E...

  • Page 27

    English rais - manual for geo 27 control if the ash is white and the walls in the combustion chamber soot-free after the stove has been used, the air regulation was set correctly and the wood was sufficiently dry. Using the wood burning stove adjustment of the air damper. The damper has 3 settings. ...

  • Page 28

    English rais - manual for geo 28 first usage a careful start pays off. Start with a small fire, so that the wood burning stove can get accustomed to the high temperature. This gives the best start and any damage is avoided. Be aware that a strange but harmless odour and smoke concoction may emanate ...

  • Page 29

    English rais - manual for geo 29 lighting and fuelling tips before firing up: open a door or window close to the wood burning stove. If there is a “storm” in the stove coming from the chimney, it is advisable to place a screwed-up piece of newspaper between the upper baffle plate and the chimney, se...

  • Page 30

    English rais - manual for geo 30 when the flames are clear - after approx. 5-10 min. - close the door. Damper - see adjustment of air damper. After approx. 10-20 min. - when you have a good bed of glowing embers - add 2-3 pieces of wood. Leave the door ajar until the fire has caught on properly - cl...

  • Page 31

    English rais - manual for geo 31 cleaning and care the wood burning stove and the chimney must be serviced by a chimney sweep at least once a year preferably twice. During cleaning and care, the stove must be cold. If the glass is sooty: - moisten a piece of paper or newspaper, dip it in the ash, an...

  • Page 32

    English rais - manual for geo 32 the fixing clips are pushed up and removed from the ska- mol on the side. The fixing clips are placed in the top right corner of the firebox. The picture on the left is a detailed view of the top right corner of the firebox (a close-up of the area is marked by a circ...

  • Page 33

    English rais - manual for geo 33 interruption of operation smoke spillage around door: could be due to too low draught in the chimney - check whether the flue or chimney is blocked - check whether the extraction hood is switched on; if it is, switch it off and open a win- dow/door in the proximity o...

  • Page 34

    English rais - manual for geo 34 spare parts diagram - rais geo 161 pos. Number item no./description 1 1/1 806060295 top plate 2 1 806010195 steel side panel - right 806010495 steel side panel - left 3 1 8061095 door 8061095h door - right hinged 4 1 806010595 fixed window 5 1 7060905sv handle for ai...

  • Page 35

    English rais - manual for geo 35.

  • Page 36

    English rais - manual for geo 36 spare parts diagram - rais geo 126 pos. Number item no./description 1 1/1 806060295 top plate 2 1 806010195 steel side panel - right 806010495 steel side panel - left 3 1 8061095 door 8061095h door - right hinged 4 1 806010595 fixed window 5 1 7060905sv handle for ai...

  • Page 37

    English rais - manual for geo 37.

  • Page 38

    English rais - manual for geo 38.

  • Page 39

    English rais - manual for geo 39.

  • Page 40

    Rais a/s industrivej 20 dk-9900 frederikshavn danmark www.Rais.Dk.