RAIS Q-BE INSERT User Manual

Summary of Q-BE INSERT

  • Page 1

    Q - b e i n s e r t b r u g e r m a n u a l b e d i e n u n g s a n l e i t u n g user manual m a n u e l d ’ u t i l i s at e u r bruksanvisning b r u k s a n v i s n i n g kÄyttÖopas g e b r u i k e r s h a n d l e i d i n g.

  • Page 2

    2 english rais/ attika - user manual q-be insert heat your place in an eco-friendly way! 3 eco-friendly advices for rational heating - common sense for both the environment preservation and saving your money 1. Efficient lighting. Use small pieces of wood (fir tree) and a suitable fire lighter - suc...

  • Page 3: Q-Be Insert

    3 25/09-2015 english rais/ attika - user manual q-be insert q-be insert revision : date : introduction ....................................................................................................................4 warranty .........................................................................

  • Page 4: Introduction

    4 english rais/ attika - user manual q-be insert introduction congratulations on your new rais / attika stove. Rais / attika wood stove is more than just a heat source, it also shows that you care about design and quality in your home. To make the most of your new stove, it is important that you car...

  • Page 5: Warranty

    5 english rais/ attika - user manual q-be insert warranty rais / attika stoves have been repeatedly tested in terms of the safety and the quality of materials and manufacturing. We grant warranty on all models, starting with the date of instal- lation. The warranty covers: • documented malfunctions ...

  • Page 6: Specifications

    6 dti danish technological institute teknologiparken kongsvang allé 29, 8000 aarhus c - danmark www.Dti.Dk telefon: +45 72 20 20 00 fax: +45 72 20 10 19 english rais/ attika - user manual q-be insert specifications dti ref.: 300-elab-2153-en / 300-elab-2153-ns q-be insert nominal output (kw): 5,9 mi...

  • Page 7: Measurements

    7 39 9 399 216 21 6 422 424 399 399 90 3 32 15 ,8 90 3 set fra bagside set fra bagside 97 0 air inlet same center as outlet q-be insert måltegning. 35 21 19 english rais/ attika - user manual q-be insert measurements.

  • Page 8: Convection

    8 english rais/ attika - user manual q-be insert convection rais / attika are convection stoves. Convection means that the air is circulated in the room evenly distributing the heat. The cold air is drawn at the base of the stove up through the convection channel and flows into the stove's combustio...

  • Page 9: Chimney

    9 english rais/ attika - user manual q-be insert chimney the smoke flue is only installable on top of the stove. The stove's flue pipe has no rear outlet. The chimney is the driving force which makes the stove function. Keep in mind that even the best stoves would not function well without necessary...

  • Page 10: Installation

    10 english rais/ attika - user manual q-be insert installation it is important that the stove is installed properly in order to preserve both the environment and safety. When installing the stove, please make sure that all local rules and regulations, including those referring to the national and eu...

  • Page 11

    11 a-a c-c a a c c a=50mm / b=350 a=100mm / b=0 a a b 10 0,5 ° møblerings afstand b english rais/ attika - user manual q-be insert q-be insert - installation of the insert installation materials: • 12,5 mm fermacell panels • calcium silicate panels (eg. 50 mm super isol or skamotec 225) • bricks hol...

  • Page 12: Corner Setting

    12 a-a c-c a a c c a=50mm / b=350 a=100mm / b=0 a a b 10 0,5 ° møblerings afstand b a-a c-c a a c c a=50mm / b=350 a=100mm / b=0 a a b 10 0,5 ° møblerings afstand b english rais/ attika - user manual q-be insert corner setting uninsulated flue inner distance (a) to non-combustible material (min) out...

  • Page 13: Fuel

    13 a-a c-c a a c c a=50mm / b=350 a=100mm / b=0 a a b 10 0,5 ° møblerings afstand b english rais/ attika - user manual q-be insert in order to guide the hot air out of the convection vents, install a beveled non-combustible plate (such as fermacell) just above the vents. Convection holes should be l...

  • Page 14: Only Use Recommended Fuels

    14 english rais/ attika - user manual q-be insert we do not recommend stoking with painted, laminated or impregnated wood, wood with a synthetic surface, painted refuse wood, chipboard, plywood, domestic waste, paper briquettes and pit coal, as this will produce malodorous smoke, which could be pois...

  • Page 15: Ventilation

    15 english rais/ attika - user manual q-be insert automatic regulation of combustion air (cleverair™) this stove is equipped with an independent and self-regulating air damper. Hence there is no damper handle. You need only to add the dry wood and light it. The rest is done by cleverair™ technology....

  • Page 16: First Usage

    16 english rais/ attika - user manual q-be insert first usage a careful start pays off. Start with a small fire, so that the wood burning stove can get accus- tomed to the high temperature. This gives the best start and any damage is avoided. Be aware that a strange but harmless odour and smoke conc...

  • Page 17

    17 2 1 3 4 5 6 7 english rais/ attika - user manual q-be insert.

  • Page 18: Control

    18 english rais/ attika - user manual q-be insert control check the stove for signs indicating the correct burning: • ash is white • the walls of the combustion chamber are free of soot conclusion: the wood is sufficiently dry. Note! If the fire has burned down too low (too small an ember), it may t...

  • Page 19: Remaining,

    19 advarsel hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der uforbrændte røggasser. Røggas kan antændes og eksplodere. Det kan give skader på materiel og i værste fald på personer. Luk aldrig helt for lufttilførslen, når der tændes op i ovnen. Hvis der kun er få gløder...

  • Page 20: Cleaning and Care

    20 english rais/ attika - user manual q-be insert cleaning and care wood burning stove and chimney must be inspected by a chimney sweep once a year. The stove must be cold during cleaning and care if the glass is sooty: • clean the glass regularly and only when the stove is cold, otherwise the soot ...

  • Page 21: Cleaning of Flue Ways

    21 english rais/ attika - user manual q-be insert lift off the smoke barrier, pull forward, lower and remove. The smoke barrier rests on 2 pins in the back and 2 spikes in the fitting in the front. Pins spikes cleaning of flue ways in order to access the smoke flue, remove the upper plate – baffle p...

  • Page 22: Malfunctions

    22 english rais/ attika - user manual q-be insert malfunctions smoke spillage around door may be caused by too weak draft in the chimney • check the flue or chimney for clogging • check whether the extraction hood is switched on; if it is, switch it off and open a win- dow/door in the proximity of t...

  • Page 23: Warning!

    23 english rais/ attika - user manual q-be insert insufficient draught in the chimney possible cause: • the temperature difference is too small, for instance, because of poorly insulated chimney • the outside temperature is high, e.G. In summer time • there is no wind • chimney is too low and shelte...

  • Page 24: Accessories Q-Be

    24 707480490 707480890 285 707480490 707480890 285 1 1 1612190 2 1 1612090 3 1 1015500 4 1 61-00 5 1 2621401sort 6 1 1611890 7 1 1610990 8 1 1611891 9 1 1611010mon 10 1 9501309 11 1 1612200 12 1 61-105 english rais/ attika - user manual q-be insert accessories q-be convection vent 707480490 - black ...

  • Page 25

    25 4 6 7 8 11 1 2 3 9 10 5 12 english rais/ attika - user manual q-be insert.

  • Page 26: Declaration of Performance

    26 english rais/ attika - user manual q-be insert declaration of performance.

  • Page 27: Ce Label

    27 en 13229:2001+a1:2003+a2:2004 raumheizer für feste brennstoffe appliance fired by wood poêle pour combustibles solides produced at: rais a/s, industrivej 20, 9900 frederikshavn, danmark 15a b-vg ec.No: 262 anordningen må kun installeres i forbindelse med ubrændbart materiale. Vkf-nr: xxxxx typ fc...

  • Page 28: Rais A/s

    Rais a/s industrivej 20 dk-9900 frederikshavn denmark www.Rais.Dk attika feuer ag brunnmatt 16 ch-6330 cham switzerland www.Attika.Ch.