Summary of Q-TEE

  • Page 1

    1 b r u g e r m a n u a l b e d i e n u n g s a n l e i t u n g u s e r m a n u a l m a n u e l d ’ u t i l i s at e u r b r u k e r v e i l e d n i n g b r u k s a n v i s n i n g k Ä y t t Ö o h j e g e b r u i k e r s h a n d l e i d i n g rais q-tee rais q-tee wall rais q-tee insert.

  • Page 2: Rais Q-Tee

    B r u g e r m a n u a l b e d i e n u n g s a n l e i t u n g u s e r m a n u a l m a n u e l d ’ u t i l i s at e u r b r u k e r v e i l e d n i n g b r u k s a n v i s n i n g k Ä y t t Ö o h j e g e b r u i k e r s h a n d l e i d i n g rais q-tee rais q-tee wall rais q-tee insert mærkeplade rai...

  • Page 3

    Brug af brændeovn / using the wood burning stove / bruk av peisovn använda kaminen / tulisijan käyttäminen / utilisation du poêle / gebruik van de kachel position 1 posisjon 1 asento 1 stand 1 position 2 posisjon 2 asento 2 stand 2 position 3 posisjon 3 asento 3 stand 3.

  • Page 4

    The oven is wrapped in packaging that is recyclable. This must be disposed of according to national rules regarding the dis- posal of waste. The glass can not be reused. The glass should be discarded along with the residual waste from ceramics and porcelain. Pyrex glass has a higher melting temperat...

  • Page 5

    5 : 4 : 10-06-2016 rais q-tee - q-tee wall - q-tee insert revision : date : introduction - warranty...............................................................................6 specifications ...................................................................................................7 inst...

  • Page 6: Introduction

    6 introduction thank you for purchasing a rais wood burning stove. These appliances have been approved by sca/hetas ltd as an intermittent operating appliances for burning wood logs only. A rais wood burning stove is more than just a heat source: it also shows that you care about design and quality ...

  • Page 7: Specifications

    7 specifications q-t ee 57 q-t ee 65 q-t ee 85 q-t ee insert nominal output (kw) 4.7 4.7 4.7 4.7 heating ar ea (m 2 ) 30-90 30-90 30-90 30-90 stove’ s width/depth/height (mm) 425x372x570 425x372x650 425x372x850 463x375x603 combustion chamber’ s width/depth/height (mm) 317x270x270 317x270x270 317x270...

  • Page 8: Installation Instructions

    8 installation instructions the following pages give instructions for the safe and proper installation of this heat- ing appliance in the uk. These instructions cover the basic principles of installation, although detail may need slight modification to suit particular local site conditions. In all c...

  • Page 9: Convection

    9 convection rais stoves are convection stoves. This means that the stove’s back and side panels are not over-heated. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. The cold air is sucked in at the base of the s...

  • Page 10

    10 a single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 125 mm. Any bend in the chimney or connecting fluepipe should not exceed 45°. 90°bends shoul...

  • Page 11: Installation

    11 installation the stove can be free standing on the floor or hung on a non-combustible wall. In ad- dition, it may be built into a wall (see specifications). When installing the wood burning stove, there are some rules which must be fol- lowed: the stove must be set up and installed in accordance ...

  • Page 12: Change of Chimney Connection

    12 change of chimney connection the stove is delivered ready for top outlet, but may be changed to back outlet in the following way: strike out the knock out plate at the rear of stove. Remove the blanking plate and the packing, and position them in the hovle at the top. Ensure that the packing is p...

  • Page 13

    13 installation distance in case of combustible wall to find out whether the wall next to where the stove is going to be installed is flam- mable, you should contact your building contractor or the local building authorities. The hearth should be able to accommodate the weight of the stove. The chim...

  • Page 14

    14 placement of q-tee 57 / q-tee 65 / q-tee 85 (free-standing) installation distance in case of combustible wall normal set-up - corner setting uninsulated flue insulated flue a. Distance to furniture (min.) 650 mm 650 mm distance to flammable materials (min.): b. In front (floor) 300 mm 300 mm c. T...

  • Page 15

    15 english rais - manual for rais q-tee installation distance in case of non-combustible wall using non insulated smoke pipe, the minimum distance to combustible wall must be 225 mm from smoke pipe. We recommend a minimum distance to non-combustible material of 50 mm (f) for cleaning considerations....

  • Page 16: Placement of Q-Tee Wall

    16 g e english rais - manual for rais q-tee placement of q-tee wall installation distance in case of non-combustible back wall and combustible side wall if the stove is to be installed above a wooden floor, it must be covered with a non-com- bustible material at a thickness and seize, which is in ac...

  • Page 17

    17 english rais - manual for rais q-tee installation distance in case of non-combustible wall we recommend a minimum distance to non-combustible material of 50 mm (f) for cleaning considerations. It should always be possible to access the access door..

  • Page 18

    18 3 4 2 1 english rais - manual for rais q-tee mounting of wall bracket and installation of q-tee wall the stove can only be mounted on non-combustible walls without cracks. Contact the chimney sweep or building expert regarding the wall’s suitability. Rais recommends that hanging and installation ...

  • Page 19

    19 5 5 6 7 8 english rais - manual for rais q-tee the bottom wall bracket (5) is mounted beneath the stove with 2 m6 screws (6). The middle screw (6) adjusts the stove vertically. The bracket can be fastened to the wall if desired, however, the screws are not to be tightened because of the downward ...

  • Page 20: Q-Tee Insert

    20 a a english rais - manual for rais q-tee q-tee insert overall dimensions.

  • Page 21: Assembly Instructions

    21 9 8 6 1 2 3 4 5 7 12 10 11 12 english rais - manual for rais q-tee assembly instructions • remove the front cover (1) and door (2) from the combustion chamber (6). Note that the door lock is to be turned clockwise before the door can be removed. • remove the vertical cover (4), the horizontal sto...

  • Page 22: Attention!

    22 m in . 6 1 3 m m m a x . 6 2 0 m m m in. 47 5m m m in . 4 73 m m m ax . 4 80 m m min. 5mm m in . 6 1 3 m m m a x . 6 2 0 m m m in . 4 73 m m m ax . 4 80 m m m in. 42 5m m min. 5mm english rais - manual for rais q-tee attention! For the sake of adjustment options for set screws, level foundation m...

  • Page 23: Convection

    23 english rais - manual for rais q-tee convection rais stoves are convection stoves. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. The cold air is sucked in at the base of the stove up through the convection c...

  • Page 24

    24 a-a a a english rais - manual for rais q-tee installation distance in case of non-combustible panels min. Convection area 600 cm 2 above the stove (may be distributed) min. Convection area 350 cm 2 below the stove (may be distributed) distance to combustible material min. 300 mm distance to non-c...

  • Page 25

    25 a-a a a english rais - manual for rais q-tee installation distance in case of brick wall / fire wall min. Convection area 600 cm 2 above the stove (may be distributed) distance to furniture min. 650 mm distance to non- combustible 0 mm (10 mm is recommended) installation height min. 400 mm min. C...

  • Page 26: For The Installer

    26 english rais - manual for rais q-tee for the installer finally before firing the stove for the first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to the chim...

  • Page 27: Drying and Storage

    27 english rais - manual for rais q-tee only use recommended fuels the following table shows the calorific value of different types of wood, which have been stored for 2 years, and which have a residual moisture of 15-17%. Wood kg dry wood pr. M 3 compared to beech/oak hornbeam 640 110% beech and oa...

  • Page 28: Room Ventilation and Stoves

    28 english rais - manual for rais q-tee by setting the interval between position 1 and 2, the energy content in the firewood is used optimally, as there is oxygen for combustion and for the burning of the pyrolysis gasses. When the flames are a clear yellow the damper has been set correctly. Finding...

  • Page 29: First Usage

    29 english rais - manual for rais q-tee first usage a careful start pays off. Start with a small fire, so that the wood burning stove can get accustomed to the high temperature. This gives the best start and any damage is avoided. Be aware that a strange odour and smoke concoction may emanate from t...

  • Page 30: Warning!!

    30 advarsel hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der uforbrændte røggasser. Røggas kan antændes og eksplodere. Det kan give skader på materiel og i værste fald på personer. Luk aldrig helt for lufttilførslen, når der tændes op i ovnen. Hvis der kun er få gløder...

  • Page 31: Cleaning and Care

    31 english rais - manual for rais q-tee cleaning and care glass most woodstoves use a ceramic glass product which is resistant to heat but requires cleaning to keep its appearance. Soot or opaque marks can easily cleaned if the marks are fresh, however if you leave the glass dirty for any length of ...

  • Page 32: Cleaning of Flue Way

    32 english rais - manual for rais q-tee cleaning of flue way the flue ways consist of a smoke converter plate and a smoke chicane. Both parts are made of vermaculit. Handle these parts carefully. Remove the smoke converter plate by tilting it to one side and turning it a little slant- wise. Pull out...

  • Page 33: Interruption of Operation

    33 english rais - manual for rais q-tee interruption of operation smoke spillage around door: could be due to too low draught in the chimney - check whether the flue or chimney is blocked - check whether the extraction hood is switched on; if it is, switch it off and open a window/door in the proxim...

  • Page 34: Spare Parts Q-Tee

    34 spare parts q-tee if spare parts other than those recommended by rais are used, the warranty is voided. All replaceable parts can be bought as spare parts from your rais distributor. For reference see spare parts drawing q-tee (front of the user manual). Pos. Quantity part no. Description 1 1 835...

  • Page 35: Spare Parts

    35 1 10 13 6 5 8 3 4 2 11 12 9 14 7 15 18 17 16 english rais - manual for rais q-tee spare parts.

  • Page 36

    36.

  • Page 37

    37.

  • Page 38

    4 6 1 2 3 5.

  • Page 39: Attika Feuer Ag

    Attika feuer ag brunnmatt 16 ch-6330 cham switzerland www.Attika.Ch rais a/s industrivej 20 dk-9900 frederikshavn denmark www.Rais.Dk.