RAIS Viva 100 L Classic Gas Installation & operation manual

Manual is about: Direct Vent Gas Stove VIVA L series

Summary of Viva 100 L Classic Gas

  • Page 1

    1 positiv outline negativ installation & operation manual rais viva l direct vent gas stove usa / canada.

  • Page 2: Usa / Canada

    2 usa / canada english rais - user manual for viva l gas report # __________ this appliance may be installed in an aftermar- ket, permanently located manufactured home (usa only) or in a mobile home, where not prohibited by local codes. This appliance is for use only with the type of gas indicated o...

  • Page 3

    3 assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort. English rais - user manual for viva l gas ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ...

  • Page 4

    4 english rais - user manual for viva l gas this manual covers the following models: viva 100 l gas – without side glass viva 100 lg gas – with side glass viva 100 l classic gas – without side glass viva 100 lg classic gas – with side glass viva 120 l gas – without side glass viva 120 lg gas – with ...

  • Page 5: Table of Contents

    5 reservations for printing errors. Table of contents important safety information ........................................................ 6 general comments ............................................................................ 9 introduction ....................................................

  • Page 6: Important Safety Information

    6 english rais - user manual for viva l gas important safety information the installation must conform with local codes or, in the absence of local codes, with the national fuel gas code, ansi z223.1 or the canadian installation code, can/cga b149. A manufactured home (usa only) or mobile home oem i...

  • Page 7: 3711901

    English rais - user manual for viva l gas children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing igniti- on. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young child...

  • Page 8

    8 english rais - user manual for viva l gas ne pas se server de cet appareil s’il a ÉtÉ plunge dans l’eau, mÊme parti- ellement. Faire inspecter l’appareil par un technician qualifiÉ et rempla- cer toute partie du systÈme de contrÔle et toute commande qui ont ÉtÉ plongÉes dans l’eau. Cet appareil pe...

  • Page 9: General Comments

    9 general comments this rais product is an extremely effective convection gas stove with a sealed combus- tion chamber for chimneys with a balanced draught. It is fitted with a burner with the latest burner technology. It has a variable heat output because it uses a special control system that makes...

  • Page 10: Introduction

    10 introduction congratulations with your new rais product. A rais stove is more than just a source of heat, it also expresses how you put the em- phasis on good design and high quality in your home. In order get the most pleasure and benefit from your new stove, it is important that you read the ma...

  • Page 11: Guarantee

    11 guarantee rais stoves are checked several times with regard to safety, as well as the quality of materials and manufacturing. We offer a guarantee on all models and the guarantee commences on the date of installation. The guarantee covers: • documented functional faults due to incorrect manufactu...

  • Page 12: Specifications

    12 english rais - user manual for viva l gas specifications input natural gas propane (lp) input rating-btu/hr 31,000 25,600 min. Input-btu/hr 8,000 8,000 orifice-marking (front) 120 80 orifice-marking (rear) 260 (x2) 100 (x2) gas supply manifold pressure 4.0”w.C. / 1.0kpa 10.8”w.C. / 2.7kpa min. Su...

  • Page 13: Installation

    13 english rais - user manual for viva l gas installation several issues must be addressed when selecting a suitable location for your viva l. The minimum clear- ances to combustible construction are listed below. In addition, ac- cess to the gas supply must be considered. The location of the stove ...

  • Page 14: Please Note!

    14 english rais - user manual for viva l gas minimum clearances to combustible construction stove to left side wall 6” (150mm) stove to corner wall 2” (51mm) stove to right side wall 6” (150mm) stove to ceiling 35” (890mm) stove to rear wall 2” (51mm) stove to 12” deep mant el 12” (305mm) max. Alcov...

  • Page 15: Massachusetts Requirements

    15 massachusetts requirements the gas stove is shipped with a 3/8” npt female connection. The gas supply piping should have a separate gas shutoff valve and a 1/8” npt plugged tapping upstream of the valve. The stove and its main control valve must be disconnected from the gas supply piping system d...

  • Page 16: Venting

    16 venting the viva l gas stove has been tested and listed for installation with 4” x 6 5/8” simpson duravent gs®, amerivent direct® , selkirk dt® , bdm pro-form dvs®, icc excel direct® and olympia chimney supply ventis® direct vent- ing components. For specific installation requirements, follow the...

  • Page 17

    17 horizontal wall vent termination flue sizing: viva l : Ø4”x6 5/8”⅝ connector on appliance. Ø4”x6 5/8”⅝maybe used throughout, alternatively, Ø5”x8” expander may be used, so that Ø5”x8” flue can be used thereafter. Flue terminal: Ø4”x6 5/8” alternatively, Ø5”x8” maximum pipe extension, for out side...

  • Page 18

    18 62 76 62 76 minimum vertical flue height: - 2 feet (600mm) flue restrictors to be fitted, Ø 4”x6 5/8”⅝: vertical rise - no restrictor vertical rise 3 – 8 feet (1-2m) - Ø62mm restrictor vertical rise > 8feet (2m) - Ø76mm restrictor vertical roof vent termination flue sizing: viva l : Ø4”x6 5/8”⅝ c...

  • Page 19

    19 vertical roof termination english rais - user manual for viva l gas.

  • Page 20

    20 vertical roof termination on angle english rais - user manual for viva l gas.

  • Page 21

    21 vertical roof termination with bends english rais - user manual for viva l gas.

  • Page 22

    22 please note: if your specific venting configuration is over 15 feet (4.5m), you must use one of the approved direct vent venting systems that utilizes a stainless steel inner liner. This requirement is part of the ansi standards and is based on testing conducted to determine where the exhaust gas...

  • Page 23

    23 vent terminal clearances (refer to illustration on page 15) a = clearance above grade, verranda, porch, deck or balcony 12 inches (30 cm) 12 inches (30 cm) b = clearance to window or door that may be opened 12 inches (30 cm) 9 inches (23 cm) c = clearance to a permanently closed window see footno...

  • Page 24

    24 english rais - user manual for viva l gas gas connection the gas supply piping should have a separate gas shut-off valve and a 1/8” npt plugged tapping upstream of the valve. The viva l and its inlet regulator and main burner valve must be disconnected from the gas supply piping system during any...

  • Page 25

    25 cold climate insulation for cold climate installations, seal all cracks around your appliance with noncombus- tible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is ...

  • Page 26

    26 english rais - user manual for viva l gas 2. Loosen the three screws on the outer flange on the top sur- face of the stove. And remove it. 3. Loosen the three screws on the inner flange on the bottom surface of the stove. And remove it. 4. Unscrew the outer cover plate at the rear of the stove an...

  • Page 27

    27 english rais - user manual for viva l gas 8. The thin side pieces of the back plate are removed by loosening the two screws, one at the top and one at the bottom. The side pieces can then be removed. 9.The back plate can now be removed and the inter- nal cover plate dismounted. 7. If the ceramic ...

  • Page 28

    28 english rais - user manual for viva l gas conversion to bottled gas (lpg) the stove is supplied configured for natural gas but can be converted to bottled gas (lpg). The conversion must only be carried out by an author- ised gas engineer. Conversion kit. Use article number 3713595. This set conta...

  • Page 29

    29 english rais - user manual for viva l gas the nozzle for the pilot light for lpg is marked "27.1" the nozzle for the pilot light for natural gas is marked "31.2" the nozzle for the main burner for lpg is marked "80" the nozzle for the main burner for natu- ral gas is marked "120".

  • Page 30

    30 english rais - user manual for viva l gas the gas unit needs to be dismantled to gain access to the nozzles. Do this in the following manner: lift the perforated plate up and out of the stove. Loosen the four screws holding the gas unit in place..

  • Page 31

    31 english rais - user manual for viva l gas replace the two nozzles for the secondary burners by loosening the coupling and care- fully pulling the pipe out. Loosen the lock- nut and then unscrew the nozzle. Fit the lpg nozzle and tighten the lock nut. Finally, re-tighten the coupling. Once the gas...

  • Page 32

    32 english rais - user manual for viva l gas remove the nozzle for the main burner by loosening the coupling and carefully pulling the pipe out and then unscrewing the noz- zle. Fit the lpg nozzle and tighten the lock nut. Finally, re-tighten the coupling. Replace the nozzle for the pilot light by l...

  • Page 33

    33 english rais - user manual for viva l gas the two air intakes for the secondary burn- er are adjusted for lpg configuration by loosening the two screws and rotating the air intake by 90°. So that both holes in the vertical pipe are now open. (the small one at the rear and the large one at the fro...

  • Page 34

    34 english rais - user manual for viva l gas the air intakes need to be reversed therefore when the stove is config- ured for lpg. The gas unit is reassembled using the four screws. Replace the perforated plate and fully assemble the stove. See section: assembly of secondary burn- ers..

  • Page 35: Fitting of

    35 english rais - user manual for viva l gas fitting of secondary burners the burners are inserted above the pipes sticking through the perforated plate. Note that there is a right burner and a left one so it is important that they are posi- tioned as shown, i.E., that the side with the extra holes ...

  • Page 36

    36 english rais - user manual for viva l gas arrangement of "embers" and ”logs" when layers of embers and the ceramic logs are arranged in the com- bustion chamber, it is important that the pilot flame and its thermosen- sor are not covered over. And that no glowing material finds its way down under...

  • Page 37: Ceramic "logs

    37 english rais - user manual for viva l gas ceramic "logs log 1 log 2 log 3 log 4 log 5 log 6 log a log b.

  • Page 38: Log 1

    38 english rais - user manual for viva l gas positioning of logs and embers log 1 spread the content of the bag of "embers" as shown in the illustra- tion. Note: the pilot area must be kept clear of "embers". Position the 8 logs as shown. Note, the two special logs marked a and b have a groove mould...

  • Page 39

    39 english rais - user manual for viva l gas log 4 log 3 log 5 log 6 log a log b.

  • Page 40: Start-Up

    40 english rais - user manual for viva l gas use only good quality alkaline batteries. The batteries should be replaced at the start of a new heating season. All batteries should be changed at the same time. The batteries are removed from the receiver by pulling the red tab. Never use sharp tools to...

  • Page 41

    41 english rais - user manual for viva l gas the batteries in the receiver must face the directions shown in the illustration. The remote control uses 2 x aa 1.5 v batteries..

  • Page 42

    42 english rais - user manual for viva l gas setting up of the electronic code in order for the remote control to work, it must be synchronised with the stove's receiver. A code is selected automatically from 65,000 possible codes. The stove and remote control are synchronised in the following manne...

  • Page 43: Commissioning

    43 english rais - user manual for viva l gas commissioning check functioning of pilot light. See user instructions for use of remote control. 1. Start the pilot light. 2. Check that the pilot light remains ignited. 3. Turn off the pilot light. Check the functioning of the main burner. 1. Turn on the...

  • Page 44

    44 english rais - user manual for viva l gas.

  • Page 45: Initial Ignition

    45 english rais - user manual for viva l gas initial ignition for the initial ignition, ensure that all packaging, labels etc. Have been removed from the stove and that the door glass has been cleaned. Begin at low output, then the stove can be slowly turned up to a great- er output. When the stove ...

  • Page 46: User Instructions

    46 english rais - user manual for viva l gas nb! The wiring for valves and receiver must be closed off before the ignition is put on. Failing to do so could damage the electronic system. Batteries – handset • low battery indicator on the handset. Batteries – receiver • low battery indicator: frequen...

  • Page 47

    47 english rais - user manual for viva l gas setting of fahrenheit or celsius child proofing setting the time 1. Press on the and buttons at the same time. Day flashes. 2. Press on the or button in order to select a number corresponding to day of the week (e.G., 1=monday, 2=tuesday, 3=wednesday, 4=t...

  • Page 48

    48 english rais - user manual for viva l gas one-button operation of handset (default setting) handset •the flame height is increased by pressing and holding down the button. •to reduce the flame height or set the appliance to pilot flame, press and hold down the button. Adjustment of flame height n...

  • Page 49

    49 english rais - user manual for viva l gas •high flame is activated by double-clicking on the button hi is displayed. If the appliance does not work, follow the guidance "shutting off gas to the appliance" countdown timer setting operating time 1. Press and hold down the button until is dis- playe...

  • Page 50

    50 english rais - user manual for viva l gas program mode on: press the button 1 or 2, on or off is displayed. Nb! The temperature set for thermostatic mode is the temperature for the operating time in program mode. If the time set for thermostatic mode is changed, the temperature for the operating ...

  • Page 51

    51 english rais - user manual for viva l gas sa:su or daily timer ( 1 , 2, 3, 4, 5, 6, 7) is select- ed. • set operating time and time for shut down by using the same approach as during "all selected" (above). • sa:su set operating time and time for shut down for both saturday and sunday. • daily ti...

  • Page 52

    52 english rais - user manual for viva l gas using stove without remote control. Where the remote control cannot be used, it is possible to turn on the stove manually. Always be very cautious if you chose to do this as the combustion chamber needs to be opened. The stove is ignited manually by openi...

  • Page 53

    53 english rais - user manual for viva l gas once the pilot flame is ignited, turn the control button so that the arrow points down to (1) on. Now the main and secondary burners can be ignited and adjusted by turn- ing the gas valve anticlockwise above to (2) on. The gas valve should be fully open f...

  • Page 54: Service.

    54 english rais - user manual for viva l gas service. Turn off the stove and shut off the gas supply. Ensure the stove is com- pletely cold before starting. Rais cannot be held responsible for injuries arising from touching a hot stove. Proposed service procedure. 1. Protect the floor by laying down...

  • Page 55

    55 maintenance instructions a qualified service agency should conduct an annual inspection and maintenance of your viva l including the overall installation and venting to keep it running safely. The following procedures should be performed only by a qualified service person. The gas supply should b...

  • Page 56

    56 the area around the injector should be inspected and any lint or foreign material must be removed with a brush or vacuum. Thermocouple maintenance the thermocouple completeness and operation must be checked. The qualified engineer must confirm that the thermocouple is in place and not cracked or ...

  • Page 57

    57 inspecting the venting an inspection of both the inner and outer vent pipes and the vent terminal should be made as part of the annual service appointment. The venting must have no blockage and be in good repair. The vent manufacturer’s instructions may provide specific details on vent inspection...

  • Page 58: Cleaning

    58 english rais - user manual for viva l gas cleaning it is advisable to clean the stove of dust and foreign bodies each new heating season and especially if the stove has not been used for a long time. This can be done with a soft brush and a vacuum cleaner. Or with a damp cloth with a non-abrasive...

  • Page 59: Accessories

    59 english rais - user manual for viva l gas accessories 2796521 - 6kg heat accumulation stone for viva 120 l, 4 in a set. 2710611sv - stainless classic top plate for rear outlet 2710612sv - stainless classic top plate for top outlet 3713506 - mains adapter (connecting the stove to a network) 371350...

  • Page 60

    60 english rais - user manual for viva l gas installation of myfire wi-fi box viva l gas can be controlled remotely via an app for your smart phone or tablet. The myfire wi-fi box is connected to the receiver, which is placed un- der the combustion chamber by opening the stove door and inserting the...

  • Page 61

    61 english rais - user manual for viva l gas nb! When configuring the myfire app you will need the ssid key and access code for the wireless network (wi-fi). *** there are more detailed configuration and guid- ance instructions at www.Myfireapp.Com *** start-up configuration 1. Download the myfire a...

  • Page 62: Spare Parts List:

    62 english rais - user manual for viva l gas spare parts list: viva 100 l gas usa - viva 120 l gas usa - viva 160 l gas usa if spare parts other than those recommended by rais are used, the guarantee will be invalidated. All replaceable parts can be purchased as spare parts from your rais dealer. Se...

  • Page 63: Spare Parts List:

    63 english rais - user manual for viva l gas spare parts list: viva 100 l g gas usa - 120 l g gas usa - 160 l g gas usa if spare parts other than those recommended by rais are used, the guarantee will be invalidated. All replaceable parts can be purchased as spare parts from your rais dealer. See fo...

  • Page 64: Spare Parts List:

    64 english rais - user manual for viva l gas pos. Number article no. Description 1 3713504 ceramic log + ember set 2 g30-zp2-312 pilot assembly natural 3 g30-zp2-271 pilot assembly lpg 4 g30-spk1 electrode 5 g60-zkis1/1500 electrode lead 6 cg30182 thermocouple 7 yg46177 injector natural front 8 ng05...

  • Page 65: Français

    65 français english rais - user manual for viva l gas.

  • Page 66

    A-a b-b a b b 10 0 0 n 470 n 518 n 4 6 2 96 7 i 1 33, 5 l 83 1 j 235 m viva 100 l gas usa a-a b-b a b b 10 0 0 n4 70 n518 n 4 6 2 96 7 i 1 33, 5 l 83 1 j 235 m.

  • Page 67

    A-a b-b a a b 12 18 235 m n 470 10 47 i 1 33, 5 l 9 11 j n 518 n 462 viva 120 l gas usa a-a b-b a a b 12 18 235 m n 470 10 47 i 1 33, 5 l 9 11 j n 518 n 462.

  • Page 68

    Viva 160 l gas usa a-a b-b a a b 161 8 235 m n 470 11 07 i 13 3, 5 l 971 j n 518 n 462 a-a b-b a a b 161 8 235 m n 470 11 07 i 13 3, 5 l 971 j n 518 n 462.

  • Page 69

    7 8 3 4 5 6 1 2 9 viva 100 l gas / viva 120 l gas / viva 160 l gas.

  • Page 70

    70 7-8 9-10 13 15 14 12 11 3 4 5 6 2 1 16 viva 100 l g gas / viva 120 l g gas / viva 160 l g gas.

  • Page 71: Installation Record

    71 installation record the installer should complete the form below that describes the details of the installa- tion. Having this written record of installation information available will greatly expedite trouble-shooting should any problem arise with your stove. The installer should keep a duplicat...

  • Page 72: Rais A/s

    Rais a/s industrivej 20 dk-9900 frederikshavn denmark www.Rais.Dk.