Raisecom RC552-FE User Manual - Chapter 7
Page 15 of 25
Chapter 7
Network Management Features
6.1 Review the Module
When RC552-FE(A) module is inserted into 16-slot chassis with management agent card, customers can review the module
status and also configure the module. The following parameters can be reviewed or configured.
Number
Name of configurable item
Value
Attribute
1
Module type
M/S1/S2/S3
Uncontrollable, non-configurable
2
Remote management (MASTER only) Enable/disable
Configurable
3
Module voltage exceeds upper
threshold (SLAVE only)
Normal, up overflow
Uncontrollable, non-configurable
4
Module voltage exceeds lower
threshold (SLAVE only)
Normal, low overflow
Uncontrollable, non-configurable
5
Module temperature (SLAVE only)
Actual temperature
Uncontrollable, non-configurable
6
Remote module power off indication
(MASTER only)
Normal, power off
Uncontrollable, non-configurable
7
Maximum transmission unit
1916Byte, 1536Byte
Configurable
8
Bandwidth management
N × 32Kb/s
‘N’ is configurable
9
Fiber interface inside loopback
Start, finish
Configurable
10
Fiber interface outside loopback
Start, finish
Configurable
11 Loopback
parameter
Exchange MAC address,
non-exchange MAC address
Configurable
12
Fiber interface to copper interface fault
propagation
Enable, disable
Configurable
13
Copper interface to fiber interface fault
propagation
Enable, disable
Configurable
14 Fiber
interface
ALS
Enable,
disable
Configurable
15
Copper interface: link status
Up, down
Uncontrollable, non-configurable
17
Copper interface: auto-negotiable
Enable, manual
Configurable
18
Copper interface: control
Enable, disable
Configurable
19
Copper interface: duplex mode
Full duplex, half duplex
Configurable
20
Copper interface: speed
10M, 100M
Configurable
21
Fiber interface: transmit link
Up, Down
Uncontrollable, non-configurable
22
Fiber interface: receive link
Up, Down
Uncontrollable, non-configurable
23
Fiber interface: signal
Normal, abnormal
Uncontrollable, non-configurable
Note: all configurable items of SLAVE module can only be set through MASTER module; only SLAVE module status can
be reviewed locally.
6.2 Configure the Module
In the above table, all configurable items can be set through ‘config module’ command in NMS. These items include copper