Contents c hapter 1 o verview ................................................................................................................................................... 1 1.1 main features .........................................................................................................
Beijing raisecom science & technology co., ltd chapter 1 overview rcms2401-30 ethernet multiplexers are fiber-optic transmission devices for dedicated communication networks, data communication networks, switching networks, and also for point-to-point networks, medium-sized and small capacity networ...
Beijing raisecom science & technology co., ltd example rc ms 2 4 01 – 30 – s2 single mode optical interface, 10-60 km 1 e1 channel 1 ethernet interface modular, single-strand fiber-optic l2 ethernet switching capability multi-service raisecom code (rc short for raisecom) note: equipments that can wo...
Beijing raisecom science & technology co., ltd chapter 2 technical specifications 2.1 e1 interface specification bit rate: 2048kbps±50ppm line code: hdb3 interface impedance: 120 Ω balanced signal electrical characteristic: compliant to itu-t g.703 transfer characteristic: compliant to itu-t g.823 j...
Beijing raisecom science & technology co., ltd chapter 3 configuration guide 3.1 description of the front panel the sketch of the rcms2401-30 front panel optical connector: the optical interface type of rcms2401-30 is sc/pc. Lal (local alarm): the red alarm indicator will be lightened when error occ...
Beijing raisecom science & technology co., ltd 1 2 3 4 5 6 7 8 off on 3.2 dip-switch setup 3.2.1 sw1 for working modes sw1 is an 8-bit dipswitch, as the figure on the right switch off (default status) on 1 enable ethernet interface auto-sensing disable ethernet interface auto-sensing 2 a) ethernet f...
Beijing raisecom science & technology co., ltd the local e1 interface will not recover until the fault disappears at remote site. 3 . the equipment will monitor the status of optical link, either transmitting alarm or receiving alarm will be taken as an optical link fault. At the mean time, the ethe...
Beijing raisecom science & technology co., ltd b . the both modules are installed in 16-slot 3u-high chassis, but only the host-site chassis is equipped with network management module. The remote-site module shall be set to “forced remote network management mode”. That is to say, the 8 th switch sha...
Beijing raisecom science & technology co., ltd z ethernet interface connect with cat. 5 or hyper cat. 5 twisted-pair cables. Either straight-through or crossover cable is ok. Z optical interface plug the tail fiber into the fiber socket to the end. 4.3.2 function configuration after connecting the c...
Beijing raisecom science & technology co., ltd appendix a cable making a.1 e1 cable making pin number 1 2 3 4 5 6 7 8 definition out+ out- not used not used in+ in- not used not used a.2 ethernet cable making use cat.5 twisted-pair cable with rj45 connector to connect this equipment. Note that the c...