RAM 1.0 Operation Manual

Manual is about: Professional Power Amplifiers

Summary of 1.0

  • Page 1

    Operation manual notice d’emploi bedienungsanleitung n0326-143 qxpbuxdoc 5/00 © 2000 by c.E. Studio-2 s.L. - spain (eec) http://www.Ramaudio.Com e-mail: support@ramaudio.Com professional power amplifiers 1.0 / 1.4 / 1.6 / 2.0 bu x x series.

  • Page 2: Caution

    Warning: the exclamation point inside an equilateral triangle indicates the existen- ce of internal components whose substi- tution may affect safety. The lightning and arrowhead symbol warns about the presence of uninsula- ted dangerous voltage. To avoid fire or electrocution risk do not expose the...

  • Page 3

    0 safety precautions 1 general information 1.1 introduction 1.2 main characteristics 2 controls: where and what? 2.1 front panel 2.2 rear panel 3 installation and operation 3.1 connections 3.1.1 dual mode (stereo) 3.1.2 parallel mode 3.1.3 bridge mode (mono) 3.2 troubleshooting 4 technical specifica...

  • Page 4

    The ram ® bux series power amps have been developped to meet the hig- hest goals in the field of professional power amplification. Their power, distor- tion and dynamics figures place them as reference in the industry. The bux series incorporate unique absolute protection systems as the cro ™ , an i...

  • Page 5

    Lokalisierung der funktionen see figure signal attenuation level control knobs: permit independent control of each channel’s attenuation (41 steps). Fault: this led shows the circuit relay on the output has open obe- ying one or several protections’ orders from the amplifier: short cir- cuit, low im...

  • Page 6

    See figure signal input: twin female neutrik ® xlr connectors for the amplifier’s signal input. Signal link: twin male neutrik ® xlr connectors for daisy chaining input signal to other amplifiers (parallel connected to female input connectors). Ground link: this switch permits connection/disconnecti...

  • Page 7

    The power switch must always be on the “off” position before plugging the amp to a properly earthed mains soc- ket (220-240v ac). The input signal fed to the amplifier can be either balanced or un-balanced. The drawing below describes both ways to wire an xlr connector for the purpose. Balanced sign...

  • Page 8

    Installation and operation installation et mise en service the amplifier can operate on three diffe- rent configurations: dual, bridge or parallel. The connections for the three modes are different. See figure - switch “off” the amp. - set the mode switch on the rear panel to “dual”. - connect the s...

  • Page 9

    8 3 4 dual channel 5 parallel inputs single channel.

  • Page 10

    In the event of incorrect connection or misfunctioning, the amp will activate one or more of its led to warn about the problem. Correct function. Clip: clipping situation on the output. No signal: no input signal is reaching the amp. Overheating: the amplifier has rea- ched the maximum operational t...

  • Page 11

    4.1 data 4.1 données techniques 4.1 technische daten technical specifications spécifications tecnische spezifikationen 10 technical specifications bux-1.0 bux-1.4 bux-1.6 bux-2.0 output power continuous average power rms, 1khz, 1.0% thd+n @ 2 Ω 2x 600 w 2x 900 w 2x 1200 w 2x 1520 w @ 4 Ω 2x 475 w 2x...

  • Page 12

    Manufactured in the eec by c.E. Studio-2 sl pol. Ind. Aldaya - c/ sierra perenxisa, nº 28 46960 aldaya - valencia - spain phone: +34 96 127 30 54 fax: +34 96 127 30 56 http://www.Ramaudio.Com e-mail: support@ramaudio.Com.