Summary of BUX 5.0
Page 1
Operation manual notice demploi bedienungsanleitung n0326-143 qxpbuxdoc 5/00 © 2000 by c.E. Studio-2 s.L. - spain (eec) http://www.Ramaudio.Com e-mail: support@ramaudio.Com professional power amplifiers bu x x 5.0
Page 2: Caution
Warning: the exclamation point inside an equilateral triangle indicates the existen- ce of internal components whose substi- tution may affect safety. The lightning and arrowhead symbol warns about the presence of uninsula- ted dangerous voltage. To avoid fire or electrocution risk do not expose the...
Page 3
0 safety precautions 1 general information 1.1 introduction 1.2 main characteristics 2 controls: where and what? 2.1 front panel 2.2 rear panel 3 installation and operation 3.1 connections 3.1.1 dual mode (stereo) 3.1.2 parallel mode 3.1.3 bridge mode (mono) 3.2 troubleshooting 4 technical specifica...
Page 4
The ram ® bux series power amps have been developped to meet the hig- hest goals in the field of professional power amplification. Their power, distor- tion and dynamics figures place them as reference in the industry. The bux series incorporate unique absolute protection systems as the cro ™ , an i...
Page 5
Lokalisierung der funktionen see figure signal attenuation level control knobs: permit independent control of each channel’s attenuation (41 steps). Fault: this led shows the circuit relay on the output has open obe- ying one or several protections’ orders from the amplifier: short cir- cuit, low im...
Page 6
See figure signal input: twin female neutrik ® xlr connectors for the amplifier’s signal input. Signal link: twin male neutrik ® xlr connectors for daisy chaining input signal to other amplifiers (parallel connected to female input connectors). Ground link: this switch permits connection/disconnecti...
Page 7
The power switch must always be on the “off” position before plugging the amp to a properly earthed mains soc- ket (220-240v ac). The input signal fed to the amplifier can be either balanced or un-balanced. The drawing below describes both ways to wire an xlr connector for the purpose. Balanced sign...
Page 8
Installation and operation installation et mise en service the amplifier can operate on three diffe- rent configurations: dual, bridge or parallel. The connections for the three modes are different. See figure - switch “off” the amp. - set the mode switch on the rear panel to “dual”. - connect the s...
Page 9
8 3 4 dual channel 5 parallel inputs single channel.
Page 10
In the event of incorrect connection or misfunctioning, the amp will activate one or more of its led to warn about the problem. Correct function. Clip: clipping situation on the output. No signal: no input signal is reaching the amp. Overheating: the amplifier has rea- ched the maximum operational t...
Page 11
4.1 data 4.1 données techniques 4.1 technische daten technical specifications spécifications tecnische spezifikationen 10 technical specifications bux-5.0 output power continuous average power rms, 1khz, 1.0% thd+n @ 2 Ω 2x 3850 w @ 4 Ω 2x 2550 w @ 8 Ω 2x 1380 w bridge @ 4 Ω 7700 w bridge @ 8 Ω 5100...
Page 12
Technical specification spécifications tecnische spezifikationen 4.2 electrical schematic 4.2 schémas 4.2 elektrische diagramme 11.
Page 13
Manufactured in the eec by c.E. Studio-2 sl pol. Ind. Aldaya - c/ sierra perenxisa, nº 28 46960 aldaya - valencia - spain phone: +34 96 127 30 54 fax: +34 96 127 30 56 http://www.Ramaudio.Com e-mail: support@ramaudio.Com.