The Ramset™power loads that are suitable for
use in standard Ramset™Low Velocity Powder
Actuated (P.A.) Tools are listed below. They are
graded according to the strength of the power
they provide.
WEAK (green) - can be used with all Ramset™
Powder Actuated (P.A.) tools
MEDIUM (yellow) - can be used with all Ramset™
Powder Actuated (P.A.) tools
STrOng (red) - can be used with all Ramset™
Powder Actuated (P.A.) tools
NOTE: For special applications; other charges
may be available on request
The FrameBoss™, Rocket, TwistLok™,
FormMaster™ and TyMaster™ tools use a strip
of power loads while the JobMaster™ uses
individual power loads.
To find the most appropriate power load for
the job, use the green/weakest power load and
set the power adjustment, if applicable, to the
minimum setting. Gradually increase power and
load strength as required to obtain a suitable
fixing.
Other Power Controls
The FrameBoss™, Rocket,
FrameMaster™ (TS750P), FixMaster™ (TS60P)
and FormMaster™ tools also have the feature
of variable power adjustment. This provides
the operator with more control over the power
delivered to the fastener.
Power Level Adjustment
• Precise control of driving power is provided by
the use of the power adjustment.
• Before use always set the power adjustment to
the minimum setting. (A)
• Select the required power setting by advancing
the power indicator to the ‘+’ symbol by
rotating the adjuster wheel anti clockwise. (B)
The colour coding of the charges is industry
standard. As such, people who are colour blind
and/or cannot distinguish between the different
power load strengths/colours should not operate
powder actuated tools.
Power Load Selection
PartNo.
Colour
Strength
PackQty
PLSGR22
Green
Weak
100
PLSYW22
Yellow
Medium
100
PLSRD22
Red
Strong
100
B
A
The FrameBoss™ variable power adjustment.
B
A
Variable power adjustment on the
FormMaster™ and TwistLok™ tools.
8