    1 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com important safety requirements & instructions ...................................................................................1 responsibilities of installers and technicians .............................................................................

  • Page 3: Ram 100 • 1000 • 5500

    2 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 installation •read and understand the instruction manual before attempting any installation. •do not exceed the equipment specifications. •insure a safe and proper installation. •install this equipment in accordance with the ul 325 specifications. •ma...

  • Page 4: Ram 100 • 1000 • 5500

    3 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com prior to installation, the following must be observed: (per ul 325.56.8.4). A) install the gate operator only when: 1. The operator is appropriate for the construction of the gate and the usage class of the gate, 2. All openings of a horizontal slide ...

  • Page 5: Ram 100 • 1000 • 5500

    4 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 vehicular horizontal slide-gate operator (or system) - a vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like. Vehi...

  • Page 6: Ram 100 • 1000 • 5500

    5 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com model ram 100 ram 1000 ram 5500 max. Gate length 20 feet 45 feet 45 feet max. Gate weight 700 lbs 1000 lbs 2500 lbs cycles continuous continuous continuous capacitor aerovox 65µƒ, 240 v, 50/60 hz, protected s 1000afc aerovox 65µƒ, 240 v, 50/60 hz, pro...

  • Page 7: Ram 100 • 1000 • 5500

    6 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 24” 6” min 4” 6 1/2” 5 3/4” 5” 3” min gate wall conduit for master-slave conduit for power conduit for low voltage wires 18” x 18” x 24” concrete pad top view gate shown open lh front installation wall gate 4” 4” min gate 6” 7 1/4” 11 3/4” base operat...

  • Page 8: Ram 100 • 1000 • 5500

    7 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com foot pedal release ram 100 front installation front installation gate shown closed tail on gate required tail wall 5 3/4” 6” min 13 7/8” figure 4 after proper use of the foot pedal, be sure to lightly kick the pedal towards the right side to spring th...

  • Page 9: Ram 100 • 1000 • 5500

    8 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 gate 6” 8 5/8” 13 1/4” base operator concrete 18” concrete 18” 24” tail 4 1/2” 3” min 4” top view gate shown closed lh front installation cl mark centers and install four 1/2-13 unc red-head anchor bolts wall top view gate shown open lh front installa...

  • Page 10: Ram 100 • 1000 • 5500

    9 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com ram 1000/ ram 5500 types of installations rear installation gate shown fully open no tail on gate required center installation gate shown fully open no tail on gate required front installation gate shown closed tail on gate required top view front vie...

  • Page 11: Ram 100 • 1000 • 5500

    10 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 figure 12 loop sensor installation reversing loops on the ground floor, prevents gate from closing when vehicle is in loop area. Exit loops on the ground floor, opens gate when vehicle crosses loop area. Ramset gate operators should always be install...

  • Page 12: Ram 100 • 1000 • 5500

    11 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com master / slave installation (rh) right hand operation requires dip switch (c7) "left/right" to be on. Dip switch “c” three pushbuttons are located under the dip switches for operation of the gate (see figure 15). The opening, stop and closing buttons...

  • Page 13: Ram 100 • 1000 • 5500

    12 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 “intelligate” control board figure 17 dip switch “a” dip switch “b” dip switch “a” 4 - 1/2 hp erd dip switch a4 works with dip switch b8 dip a4 b8 sensitivity off off most sensitive on off 1/2 hp — medium sensitivity off on 3/4 hp — medium sensitivit...

  • Page 14: Ram 100 • 1000 • 5500

    13 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com dip switch configuration dip switch “c” 2; “full rev erd” changes how long a gate will reverse when an obstruction is met when closing. Sw. Function: on reverses until the open limit is reached off reverses for 2 seconds and stops again. Dip switch “...

  • Page 15: Ram 100 • 1000 • 5500

    14 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 limit switches radio receiver figure 18 terminal strip connections.

  • Page 16: Ram 100 • 1000 • 5500

    15 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com terminal # 1 - common: low voltage common. Terminal # 2 - rev loop: stops the gate from closing. If the gate is open, it holds the gate open. If the gate is closing, it stops and reopens the gate. If the gate is closed, the gate will remain closed. T...

  • Page 17: Ram 100 • 1000 • 5500

    16 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 plug-in power transformer 40va. Dipswitches automatic timer, prewarn, constant warning, secure close, full reverse erd, radio cycle, one pass, low / high erd, adjustment, close delay, open delay and left / right. Relay connections indicator lights, a...

  • Page 18: Ram 100 • 1000 • 5500

    17 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com jp9 - input power: 1,2) 24 vac power. Connection from external transformer to power control board. Jp3 - 3 button: 1) open 2) stop 3) close 4) common used with a 3-button station to open, stop, and close the gate. The open and close are normally open...

  • Page 19: Ram 100 • 1000 • 5500

    18 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 parts diagram ram 100 figure 20 3 21 1 16 19 41 30 29 28 50 48 47 49 46 26 13 17 10 24 24 39 7 17 14 35 36 31 20 38 44 5 11 45 51 59 60 61 42 33.

  • Page 20: Ram 100 • 1000 • 5500

    19 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com ram 1000 • ram 5500 figure 21 2 41 22 27 42 44 16 19 15 8 23 9 20 32 18 38 37 36 35 28 30 25 29 63 64 65 43 34 40 33 4 12 52 62 55 54 56 58 53 57 6 parts diagram.

  • Page 21: Ram 100 • 1000 • 5500

    20 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 bill of materials for: ram 100 • ram 1000 • ram 5500 item part # part description ram 100 ram 1000 ram 5500 1 800-00-00 chassis - ram 100 1 2 800-00-01 chassis - ram 1000/5500 1 1 3 800-02-03 gear reducer - size 43, ratio 30:1 (c-face) 1 4 800-02-06 ...

  • Page 22: Ram 100 • 1000 • 5500

    21 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com bill of materials for: ram 100 • ram 1000 • ram 5500 item part # part description ram 100 ram 1000 ram 5500 45 800-75-20 foot pedal release assembly - ram 100 1 46 800-06-11 sprocket, clutch release - 41b21h 1 47 800-22-00 spring - 1 1/4" x 1 1/4" 1 ...

  • Page 23: Ram 100 • 1000 • 5500

    22 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 gate entrance safety precautions 1. Never let children operate or play with gate con- trols. Keep the controls away from children. 2. The entrance is for vehicles only. Pedestrians should use a separate entrance. 3. Always keep people, children and o...

  • Page 24: Ram 100 • 1000 • 5500

    23 ram 100 • 1000 • 5500 ramset www.Ramsetinc.Com ask your technician about all the features of our new ramset operator. Safety devices, such as reversing loops, phantom loops, photo eyes, or miller edges must be installed on your gate before the operator may be used. Ask your technician which safet...

  • Page 25: Ram 100 • 1000 • 5500

    24 ramset www.Ramsetinc.Com ram 100 • 1000 • 5500 troubleshooting table condition possible causes solution no lights are ‘on’. 1. Circuit breaker popped. 2. 1/2 amp. Fuse blown. 3. Power supply damaged on control board. 1. Reset circuit breaker. 2. Replace 1/2 amp. Fuse. 3. Return control board for ...

  • Page 26