Ramsond Sunray 1500 User manual - page 11
Ramsond SunRay 1500 and 3000 Inverters
Instruction Manual (v. 34411)
©
Ramsond Corporation. All right reserved. Ramsond and Sunray are trademarks of Ramsond Corp.
Page 10.
Top Display (Watt/Error) – SunRay 3000
The top display (WATT/ERROR) displays the load wattage (watt/h) of the load attached to the
inverter. In the event of error, it also displays a 3 character error message.
Error codes are as follows:
Bottom Display (Volt) – SunRay 3000
The bottom display shows the voltage of the battery bank.
Remote Starter Connection Port
SunRay inverters are Remote-Ready. They feature a REMOTE connection port, located on
the front panel. The optional remote starting systems connect to this port. With the optional
remote starting systems, the Ramsond SunRay inverter can be turned on or off from distances
up to 100 feet (30+ meters) away.
There are two type of remote starting systems available; the Wired and Wireless. The Wired
system consists of a remote switch and connecting wire. The Wireless system consists of a
Receiver and wireless Transmitter. Both of these remote starting systems provide convenient
mechanisms to start or stop the inverter from a distance. Each of these systems is supplied
with a connecting wire assembly. The connecting wire (between the Receiver/Switch and
inverter) can be lengthened as needed, using standard telephone cable and connectors.
The optional remote systems can be purchased from your local Ramsond dealer.
Error Code
Error Description
LUP
Low Voltage
OUP
High Voltage
OCP
Temperature Protection
OLP
Overload Protection
OPP
Short Circuit Protection