Randell 41048A Operator's Manual - Electrical Diagram

Other manuals for 41048A: Specifications
Manual is about: Refrigerated Wall Mount Display Merchandiser

Summary of 41048A

  • Page 1

    10/10/2008 pp mnl0807 operator’s manual this manual provides information on installation, operating, maintenance, trouble shooting & replacement parts for 42000a refrigerated wall mount display merchandiser 42036a 42048a 42060a notify carier of damage at once. It is the responsibility of the consign...

  • Page 2: Table Of Contents

    2 2 2 2 800-621-8560 table of contents page 2………………………………….…………congratulations page 3……………………………………parts & service hotline page 3………………………………...…serial number location page 4-7……………………………….Randell limited warranty page 8…………………………………………unit specifications page 9-10.………………………………………...Unit installatio...

  • Page 3: 800-621-8560

    Unifiedbrands.Net 3 in addition, all randell food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians. Retain this manual for future reference. Notice: due to a continuous program of product improvement, randell...

  • Page 4: Warranty Policies

    4 4 4 4 800-621-8560 warranty policies randell believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit comes the peace of mind that this unit has been thoroughly engineered, properly tested and manufactured to excruciating tolerance...

  • Page 5

    Unifiedbrands.Net 5 temperature adjustments are not covered under warranty, due to the wide range of ambient conditions. For warranty inquiries call our field service department at: 1-800-621-8560. When optional 5 year compressor warranty applies 1. Provide reimbursement to an asa for the cost of lo...

  • Page 6

    6 6 6 6 800-621-8560 notice: food loss is not covered under warranty 3. Repairs caused by abuse such as broken glass, freight damage, excessive force, or scratches and dents. 4. Electrical component failure due to water damage from cleaning procedures. Quotations verbal quotations are provided for c...

  • Page 7

    Unifiedbrands.Net 7 damages all crating conforms to general motor carrier specifications. To avoid concealed damage, we recommend inspection of every carton upon receipt. In the event the item shows rough handling or visible damage to minimize liability, a full inspection is necessary upon arrival. ...

  • Page 8: Unit Specifications

    8 8 8 8 800-621-8560 unit specifications 42048a shown model l d h storage cu. Ft. Shelves sq. Ft. Hp volt amps nema ship wt. 42036a 36” 22.5” 20” 4 4 ¼ 115/60/1 6.2 5-15p 235 42048a 48” 22.5” 20” 5.6 5.5 ¼ 115/60/1 6.2 5-15p 275 42060a 60” 22.5” 20” 6.9 7 ¼ 115/60/1 6.2 5-15p 360

  • Page 9: Unit Installation

    Unifiedbrands.Net 9 unit installation selecting a location for your new unit the following conditions should be considered when selecting a location for your unit: 1. Wall load: the area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined ...

  • Page 10

    10 10 10 10 800-621-8560 unit installation – con’t. 6. Carefully lift unit and lower unit onto the wall mounting bracket making sure the unit mounting bracket is securely in the wall mount bracket. 7. Assure unit is level. Shimming may be required so unit is tilting at top or bottom. 8. Plug in unit...

  • Page 11: Unit Operation

    Unifiedbrands.Net 11 unit operation randell has preset the cold control to ensure that your unit runs at an optimum temperature, but due to varying ambient conditions, including elevation, food product as well as type of operation, you may need to alter this temperature. Additional adjustments can b...

  • Page 12

    12 12 12 12 800-621-8560 unit operation – con’t. Door removal: 1. Locate outside door (sticker to identify door in lower corner of door) 2. Open door 3” 3. Lift door up 4. Pull lower part of door out away from unit. 5. Repeat for inside door door installation: 1. Locate inside door (sticker to ident...

  • Page 13

    Unifiedbrands.Net 13 unit operation – con’t. Door adjustment: roller bearings on bottom of each door may be adjusted to allow for proper seal of glass door. To look for proper door sealing assure that the bumper gasket of each door touches the entire vertical side of the door frame. No gaps should b...

  • Page 14: Preventive Maintenance

    14 14 14 14 800-621-8560 preventive maintenance randell strongly suggests a preventive maintenance program which would include the following monthly procedures: if a failure of the equipment is a direct result of any of the preventative maintenance guidelines being neglected the repairs will not be ...

  • Page 15

    Unifiedbrands.Net 15 preventive maintenance (cont.) proper maintenance of equipment is the ultimate necessity in preventing costly repairs. By evaluating each unit on a regular schedule, you can often catch and repair minor problems before they completely disable the unit and become burdensome on yo...

  • Page 16: Electrical Diagram

    16 16 16 16 800-621-8560 electrical diagram.

  • Page 17: Trouble Shooting Guide

    Unifiedbrands.Net 17 trouble shooting guide symptom possible cause procedure unit doesn't run 1. No power to unit 1. Plug in unit 2. Temperature control turned off 2. Check temperature control 3. Temperature control faulty 3. Test temperature control 4. Compressor overheated 4. Clean condenser coil ...

  • Page 18: Replacement

    18 18 18 18 800-621-8560 replacement parts 42000a series.

  • Page 19: Replacement

    Unifiedbrands.Net 19 replacement parts 42000a series.

  • Page 20: Replacement

    20 20 20 20 800-621-8560 replacement parts list 42000a series item # part # description 42036a 42048a 42060a 1 hd shl005 shelf 8 ½” x 31 7/8” x 1a hd shl006 shelf 8 ½” x 43 7/8” x 1b hd shl007 shelf 8 ½” x 55 7/8” x 2 hd frm036 frame & door assy 17” x 31 7/8” x 2a hd frm048 frame & door assy 17” x 4...

  • Page 21

    Unifiedbrands.Net 21 item # part # description 42036a 42048a 42060a 22 rf fan005 fan blade x x x 23 el mtr0230 evap fan motor x x x 24 rp brk1050 motor mount bracket x x x 25 rf coi120b evap coil x x x 26 rf fan010 fan guard x x x 27 rp dfl0801 evap housing air deflector x x x 28 rp grd0801 cond fan...