Rangemaster OPLHD100 Instruction Manual

Manual is about: OPAL HOOD

Summary of OPLHD100

  • Page 1

    Oplhd60 – oplhd90 – oplhd100 – opal hood instructions manual www.Rangemaster.Co.Uk.

  • Page 2: Index

    2 2 index recommendations and suggestions ..................................................................................................................... 3 characteristics .............................................................................................................................

  • Page 3

    En 3 3 recommendations and suggestions the instructions for use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. Installation • the manufacturer will not be held liable for any damages resulting f...

  • Page 4: Characteristics

    En 4 4 characteristics dimensions 330 380 min. 330 - max. 640 300 200 components ref. Q.Ty product components 1 1 hood body, complete with: controls, light, blower, filters 2.1 1 upper section 2.2 1 lower section 8 1 directional air outlet grille 9 1 reducer flange ø 150 – 120 mm 10 1 adapting ring ...

  • Page 5: Installation

    En 5 5 installation wall drilling and bracket fixing 11a 1 1 2 2 140 11 12a 164 164 788 540 450 140 x 1÷2 7.2.1 as a first step, proceed with the following drawings: • a vertical line up to the ceiling or up to the upper limit, at the centre of the area in which the hood is to be fitted; • a horizon...

  • Page 6: Ø 125

    En 6 6 fitting the hood body • open the doors/the door (see section open panels). • remove the metal grease filters using the handles provided. • adjust the two screws vr, in the brackets 11a, so that they are at the start of their travel. • hook the hood body to the two brackets 11a. • from the ins...

  • Page 7

    En 7 7 recirculation version air outlet to install the recirculation version of the hood, the activated charcoal filter must be fitted, see paragraph “ activated charcoal filter (recirculation version)”. • screw the filter cover onto the air outlet, using four screws 12c (2.9 x 12.5). • fix the dire...

  • Page 8: Use

    En 8 8 use control panel t1 t2 t3 t4 l button function t1 turns the motor off. - t2 turns the motor on at speed one buttons t1+t2 are on. T3 turns the motor on at speed two buttons t1+t3 are on. Press and hold for 2 seconds to enable shutdown with a 20 minute delay (mo- tor+lights). It is possible t...

  • Page 9: Maintenance

    En 9 9 maintenance opening panel • open the panel by pulling it. • the panel can be locked in any position. • clean the outside with a damp cloth and neutral detergent. • clean the inside using a damp cloth and neutral detergent; do not use wet cloths or sponges, or jets of water; do not use abrasiv...

  • Page 10

    En 1 10 activated charcoal filter (recirculation version) these filters are not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently with heavy usage. Replacing the activated charcoal filter • open the comfort panels pulling them down...

  • Page 12

    991.0301.958_ver4 aga rangemaster group plc.