Ransburg Vector AA90 79580 Service Manual

Manual is about: Applicators

Summary of Vector AA90 79580

  • Page 1

    Service manual ah-07-01.8 ah-07-01.8 ah-07-01.8 ah-07-01.8 ah-07-01.8 (replaces ah-07-01.7) june 2010 impor impor impor impor import t t t tant ant ant ant ant: before using this equipment, : before using this equipment, : before using this equipment, : before using this equipment, : before using th...

  • Page 2

    Ah-07-01.8 n o t e : n o t e : n o t e : n o t e : n o t e : this manual has been changed from revision ah-07-01.7 ah-07-01.7 ah-07-01.7 ah-07-01.7 ah-07-01.7 to revision ah-07-01.8. Ah-07-01.8. Ah-07-01.8. Ah-07-01.8. Ah-07-01.8. Reasons for this change are noted under “manual change summary” insid...

  • Page 3

    Ah-07-01.8 safety: safety: safety: safety: safety: safety precautions............................................................................................................ Hazards / safeguards.........................................................................................................

  • Page 4

    Ah-07-01.8 vector aa90 applicators - contents page page page page page maintenance: maintenance: maintenance: maintenance: maintenance: suitable solvents for cleaning vector aa90 applicators.................................................................................................. Routine sch...

  • Page 5

    Ah-07-01.8 parts identification: parts identification: parts identification: parts identification: parts identification: 79580 vector aa90 applicator model identification............................................ 79581 vector aa90 applicator model identification.......................................

  • Page 6

    Ah-07-01.8 vector aa90 applicators - safety 1 1 1 1 1 safety precautions safety precautions safety precautions safety precautions safety precautions before operating, maintaining or servicing any itw ransburg electrostatic coating system, read and understand all of the technical and safety literatur...

  • Page 7

    Ah-07-01.8 vector aa90 applicators - safety 2 2 2 2 2 a r e a a r e a a r e a a r e a a r e a tells where hazards may occur. H a z a r d h a z a r d h a z a r d h a z a r d h a z a r d tells what the hazard is. S a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g...

  • Page 8

    Ah-07-01.8 vector aa90 applicators - safety 3 3 3 3 3 a r e a a r e a a r e a a r e a a r e a tells where hazards may occur. H a z a r d h a z a r d h a z a r d h a z a r d h a z a r d tells what the hazard is. S a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g...

  • Page 9

    Ah-07-01.8 vector aa90 applicators - safety 4 4 4 4 4 a r e a a r e a a r e a a r e a a r e a tells where hazards may occur. H a z a r d h a z a r d h a z a r d h a z a r d h a z a r d tells what the hazard is. S a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g...

  • Page 10

    Ah-07-01.8 vector aa90 applicators - safety 5 5 5 5 5 a r e a a r e a a r e a a r e a a r e a tells where hazards may occur. H a z a r d h a z a r d h a z a r d h a z a r d h a z a r d tells what the hazard is. S a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g...

  • Page 11

    Ah-07-01.8 vector aa90 applicators - safety 6 6 6 6 6 a r e a a r e a a r e a a r e a a r e a tells where hazards may occur. H a z a r d h a z a r d h a z a r d h a z a r d h a z a r d tells what the hazard is. S a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g u a r d s s a f e g...

  • Page 12

    Ah-07-01.8 vector aa90 applicators - atex 7 7 7 7 7 european a european a european a european a european atex directive 94/9/ec, annex ii, 1.0.6 tex directive 94/9/ec, annex ii, 1.0.6 tex directive 94/9/ec, annex ii, 1.0.6 tex directive 94/9/ec, annex ii, 1.0.6 tex directive 94/9/ec, annex ii, 1.0.6...

  • Page 13

    Ah-07-01.8 vector aa90 applicators - atex 8 8 8 8 8 label 79515 label 79515 label 79515 label 79515 label 79515 v v v v vector aa90 79580 and 79581 ector aa90 79580 and 79581 ector aa90 79580 and 79581 ector aa90 79580 and 79581 ector aa90 79580 and 79581 a a a a atex product marking tex product mar...

  • Page 14

    Ah-07-01.8 configuration dwg. 79952 rev a "e" designations "b" designations "c" designations "a" designations "d" designations 9 9 9 9 9.

  • Page 15

    Ah-07-01.8 configuration dwg. 79952 rev a option "c" designations spray tip size 1 for 0811 tip without preorifice-part number: 79691-0811 2 for 0813 tip without preorifice-part number: 79691-0813 3 for 1011 tip without preorifice-part number: 79691-1011 4 for 1015 tip without preorifice-part number...

  • Page 16

    Ah-07-01.8 1 1 1 1 1 1 1 1 1 1 configuration dwg. 79953 rev a "e" designations "b" designations "c" designations "a" designations "d" designations.

  • Page 17

    Ah-07-01.8 1 2 1 2 1 2 1 2 1 2 configuration dwg. 79953 rev a option "a" designations cable length 0 for no cable 1 for 10 meter cable-part number: 79519-10 2 for 15 meter cable-part number: 79519-15 3 for 20 meter cable-part number: 79519-20 4 for 25 meter cable-part number: 79519-25 5 for 30 meter...

  • Page 18

    Ah-07-01.8 the itw ransburg the itw ransburg the itw ransburg the itw ransburg the itw ransburg electrost electrost electrost electrost electrosta a a a atic tic tic tic tic vector aa90 process vector aa90 process vector aa90 process vector aa90 process vector aa90 process this is a combined air/air...

  • Page 19

    Ah-07-01.8 vector aa90 applicators - introduction 1 4 1 4 1 4 1 4 1 4 n o t e s n o t e s n o t e s n o t e s n o t e s.

  • Page 20

    Ah-07-01.8 vector aa90 applicators - introduction 1 5 1 5 1 5 1 5 1 5 110/120 vac 220/240 vac 79513-131 79513-132 -85 kv dc -85 kv dc voltage voltage voltage voltage voltage designation designation designation designation designation maximum maximum maximum maximum maximum output output output outpu...

  • Page 21

    Ah-07-01.8 vector aa90 applicators - introduction 1 6 1 6 1 6 1 6 1 6 figure 1: aa90 cascade solventborne electrostatic spray applicator features - air assist figure 1: aa90 cascade solventborne electrostatic spray applicator features - air assist figure 1: aa90 cascade solventborne electrostatic sp...

  • Page 22

    Ah-07-01.8 vector aa90 applicatorss - introduction 1 7 1 7 1 7 1 7 1 7 figure 2: 79513-13x cascade control unit features figure 2: 79513-13x cascade control unit features figure 2: 79513-13x cascade control unit features figure 2: 79513-13x cascade control unit features figure 2: 79513-13x cascade c...

  • Page 23

    Ah-07-01.8 vector aa90 applicators - introduction 1 8 1 8 1 8 1 8 1 8 specifica specifica specifica specifica specifications tions tions tions tions sol sol sol sol solventborne ventborne ventborne ventborne ventborne (c (c (c (c (classic lassic lassic lassic lassic))))) fluid pressure: fluid pressu...

  • Page 24

    Ah-07-01.8 vector aa90 applicators - introduction 1 9 1 9 1 9 1 9 1 9 figure 3: aa90 classic solventborne electrostatic spray applicator features - air assist figure 3: aa90 classic solventborne electrostatic spray applicator features - air assist figure 3: aa90 classic solventborne electrostatic sp...

  • Page 25

    Ah-07-01.8 vector aa90 applicators - introduction 2 0 2 0 2 0 2 0 2 0 figure 4: 79344-14x 9050 power supply features figure 4: 79344-14x 9050 power supply features figure 4: 79344-14x 9050 power supply features figure 4: 79344-14x 9050 power supply features figure 4: 79344-14x 9050 power supply feat...

  • Page 26

    Ah-07-01.8 vector aa90 applicators - installation inst inst inst inst installa alla alla alla allation tion tion tion tion • position all non-approved electrical apparatus (including, but not limited to, high voltage power supplies, fluid pumps, and air compressors) outside of the hazardous location...

  • Page 27

    Ah-07-01.8 vector aa90 applicators - installation 2 2 2 2 2 2 2 2 2 2 figure 5: typical aa90 cascade applicator installation features figure 5: typical aa90 cascade applicator installation features figure 5: typical aa90 cascade applicator installation features figure 5: typical aa90 cascade applica...

  • Page 28

    Ah-07-01.8 vector aa90 applicators - installation 2 3 2 3 2 3 2 3 2 3 1 79512-00 enclosure assembly, 9050 cascade (ref. - not in kit) -- 2 79493-00 screw, pan head, 8-32 phillips, stainless steel 8 3 79489-00 bracket, machined, 9050 cascade 1 4 79488-00 hinge, machined, 9050 cascade 1 5 79490-00 bra...

  • Page 29

    Ah-07-01.8 vector aa90 applicators - installation 2 4 2 4 2 4 2 4 2 4 5 2 4 5 2 5 3 2 5 2 1 1 1 1 2 5 2 3 5 2 5 2 4 5 figure 6: 79527-00 9050 cascade enclosures figure 6: 79527-00 9050 cascade enclosures figure 6: 79527-00 9050 cascade enclosures figure 6: 79527-00 9050 cascade enclosures figure 6: ...

  • Page 30

    Ah-07-01.8 vector aa90 applicators - installation 2 5 2 5 2 5 2 5 2 5 electrical noise electrical noise electrical noise electrical noise electrical noise general information - classic or general information - classic or general information - classic or general information - classic or general infor...

  • Page 31

    Ah-07-01.8 vector aa90 applicators - installation 2 6 2 6 2 6 2 6 2 6 i/o connections i/o connections i/o connections i/o connections i/o connections (cascade units) (cascade units) (cascade units) (cascade units) (cascade units) for maximum noise immunity, i/o wiring should be run in conduit or cab...

  • Page 32

    Ah-07-01.8 vector aa90 applicators - installation 2 7 2 7 2 7 2 7 2 7 ac input ac input ac input ac input ac input connections connections connections connections connections (((((cascade units cascade units cascade units cascade units cascade units))))) for non-conduit installations, plug the detac...

  • Page 33

    Ah-07-01.8 vector aa90 applicators - installation 2 8 2 8 2 8 2 8 2 8 > failure to connect interlocks could result in fire or explosion. W a r n i n g w a r n i n g w a r n i n g w a r n i n g w a r n i n g !!!!! To install the control unit interlocks perform the following: 1. Turn the control unit ...

  • Page 34

    Ah-07-01.8 vector aa90 applicators - installation 2 9 2 9 2 9 2 9 2 9 figure 10a: location of terminal blocks figure 10a: location of terminal blocks figure 10a: location of terminal blocks figure 10a: location of terminal blocks figure 10a: location of terminal blocks tb1 and tb2 tb1 and tb2 tb1 an...

  • Page 35

    Ah-07-01.8 vector aa90 applicators - installation 3 0 3 0 3 0 3 0 3 0 low vol low vol low vol low vol low volt t t t tage cable age cable age cable age cable age cable connect the low voltage cable from the control unit to the applicator using a wrench to tighten. Figure 11: daisy chained cable figu...

  • Page 36

    Ah-07-01.8 vector aa90 applicators - installation 3 1 3 1 3 1 3 1 3 1 figure 12: typical aa90 classic applicator installation features figure 12: typical aa90 classic applicator installation features figure 12: typical aa90 classic applicator installation features figure 12: typical aa90 classic app...

  • Page 37

    Ah-07-01.8 vector aa90 applicators - installation 3 2 3 2 3 2 3 2 3 2 figure 13: typical power supply mounting figure 13: typical power supply mounting figure 13: typical power supply mounting figure 13: typical power supply mounting figure 13: typical power supply mounting the power supply may be f...

  • Page 38

    Ah-07-01.8 vector aa90 applicators - installation 3 3 3 3 3 3 3 3 3 3 figure 15: i/o cable stripping figure 15: i/o cable stripping figure 15: i/o cable stripping figure 15: i/o cable stripping figure 15: i/o cable stripping figure 14: cable grommet figure 14: cable grommet figure 14: cable grommet ...

  • Page 39

    Ah-07-01.8 vector aa90 applicators - installation 3 4 3 4 3 4 3 4 3 4 4. Install the ac input wiring (0.8mm 2 (18 awg) minimum) through the conduit adapter plate using conduit and wire to tb1 as follows: hot/line to tb1-l1 neutral/common to tb1-n ground to tb1-earth ground safety ground safety groun...

  • Page 40

    Ah-07-01.8 vector aa90 applicators - installation 3 5 3 5 3 5 3 5 3 5 interlocks interlocks interlocks interlocks interlocks interlocks required by code are as follows: • booth fan interlock - when the booth fan is on, a contact closure is made. • conveyor interlock - when the conveyor is moving, a ...

  • Page 41

    Ah-07-01.8 vector aa90 applicators - installation 3 6 3 6 3 6 3 6 3 6 > always always always always always double check that the power supply is unplugged from its ac outlet before working with any internal wiring. W a r n i n g w a r n i n g w a r n i n g w a r n i n g w a r n i n g !!!!! 3. Using ...

  • Page 42

    Ah-07-01.8 vector aa90 applicators - installation 3 7 3 7 3 7 3 7 3 7 line hose - air line hose - air line hose - air line hose - air line hose - air (((((classic and cascade classic and cascade classic and cascade classic and cascade classic and cascade))))) itw ransburg supplies a standard 2m whip...

  • Page 43

    Ah-07-01.8 vector aa90 applicators - installation 3 8 3 8 3 8 3 8 3 8 n o t e s n o t e s n o t e s n o t e s n o t e s.

  • Page 44

    Ah-07-01.8 vector aa90 applicators - operation opera opera opera opera operation tion tion tion tion 3 9 3 9 3 9 3 9 3 9 safe opera safe opera safe opera safe opera safe operation tion tion tion tion • ground all operators by requiring that they hold the applicator handle with a bare hand. • ground ...

  • Page 45

    Ah-07-01.8 vector aa90 applicatorss - operation 4 0 4 0 4 0 4 0 4 0 overlap overlap overlap overlap overlap for the best "hiding" and uniformity of film thickness, the stroke overlap should be approximately 50%. There should be some overlap at edges of the part to increase edge coverage. Overlap req...

  • Page 46

    Ah-07-01.8 vector aa90 applicators - operation 4 1 4 1 4 1 4 1 4 1 the aa90 applicator incorporates a new feature, that being a locating air cap. Refer to figure 18 for a view showing the locating pin. This feature gives the capability to spray with a fan pattern in either horizontal or vertical pos...

  • Page 47

    Ah-07-01.8 vector aa90 applicators - operation 4 2 4 2 4 2 4 2 4 2 kv test jumper kv test jumper kv test jumper kv test jumper kv test jumper to assist in testing and troubleshooting, a jumper (j8) has been added to the main pc board. By covering (shorting) both terminals of this jumper, the high vo...

  • Page 48

    Ah-07-01.8 vector aa90 applicators - operation 4 3 4 3 4 3 4 3 4 3 figure 22: safety fault display figure 22: safety fault display figure 22: safety fault display figure 22: safety fault display figure 22: safety fault display safety fault (sf) safety fault (sf) safety fault (sf) safety fault (sf) s...

  • Page 49

    Ah-07-01.8 feedback fault (ff) feedback fault (ff) feedback fault (ff) feedback fault (ff) feedback fault (ff) (cascade units) (cascade units) (cascade units) (cascade units) (cascade units) this fault will occur if the microprocessor detects a loss of the current feedback signal. If this occurs, re...

  • Page 50

    Ah-07-01.8 powering up powering up powering up powering up powering up control unit control unit control unit control unit control unit (((((cascade units cascade units cascade units cascade units cascade units))))) when the ac power is turned on, the unit will display the pc board applicator type n...

  • Page 51

    Ah-07-01.8 vector aa90 applicators - operation 4 6 4 6 4 6 4 6 4 6 setpoint setpoint setpoint setpoint setpoint vol vol vol vol volt t t t tage age age age age the vector applicator system has three voltage setpoints 1, 2, and 3. Each of these voltages can be individually adjusted between 20 and ful...

  • Page 52

    Ah-07-01.8 vector aa90 applicators - operation 4 7 4 7 4 7 4 7 4 7 > do not do not do not do not do not turn the applicator off using the applicator button in place of interlocking with a solvent supply for flushing. The applicator must be interlocked with solvent supply such that when the solvent i...

  • Page 53

    Ah-07-01.8 vector aa90 applicators - operation 4 8 4 8 4 8 4 8 4 8 applicator switch lockout applicator switch lockout applicator switch lockout applicator switch lockout applicator switch lockout the applicator switch may be de-activated for applications that require the operator to not be able to ...

  • Page 54

    Ah-07-01.8 vector aa90 applicators - operation 4 9 4 9 4 9 4 9 4 9 basic opera basic opera basic opera basic opera basic operation tion tion tion tion (cascade units) (cascade units) (cascade units) (cascade units) (cascade units) t t t t triggering riggering riggering riggering riggering high volta...

  • Page 55

    Ah-07-01.8 vector aa90 applicators - operation 5 0 5 0 5 0 5 0 5 0 description description description description description applicator type applicator type applicator type applicator type applicator type 6 st st st st star ar ar ar art t t t t-up -up -up -up -up displa displa displa displa displa...

  • Page 56

    Ah-07-01.8 vector aa90 applicators - operation 5 1 5 1 5 1 5 1 5 1 basic opera basic opera basic opera basic opera basic operations tions tions tions tions (classic units) (classic units) (classic units) (classic units) (classic units) t t t t triggering riggering riggering riggering riggering high ...

  • Page 57

    Ah-07-01.8 vector aa90 applicators - operation 5 2 5 2 5 2 5 2 5 2 figure 38: displaying "high voltage on" figure 38: displaying "high voltage on" figure 38: displaying "high voltage on" figure 38: displaying "high voltage on" figure 38: displaying "high voltage on" time time time time time to reset...

  • Page 58

    Ah-07-01.8 vector aa90 applicators - operation 5 3 5 3 5 3 5 3 5 3 to remove the to remove the to remove the to remove the to remove the applica applica applica applica applicat t t t tor from the or from the or from the or from the or from the work site work site work site work site work site 1. Fl...

  • Page 59

    Ah-07-01.8 vector aa90 applicators - operation 5 4 5 4 5 4 5 4 5 4 applica applica applica applica applicat t t t tor rep or rep or rep or rep or repair air air air air all repairs should be made on a clean, flat surface. If a vise is used to hold parts during service or repair, do not clamp onto pl...

  • Page 60

    Ah-07-01.8 maintenance maintenance maintenance maintenance maintenance vector aa90 applicators - maintenance 5 5 5 5 5 5 5 5 5 5 suit suit suit suit suitable sol able sol able sol able sol able solvents vents vents vents vents for cleaning for cleaning for cleaning for cleaning for cleaning vector a...

  • Page 61

    Ah-07-01.8 vector aa90 applicators - maintenance 5 6 5 6 5 6 5 6 5 6 daily (or at start of each shift) daily (or at start of each shift) daily (or at start of each shift) daily (or at start of each shift) daily (or at start of each shift) • verify that all solvent safety containers are grounded! • c...

  • Page 62

    Ah-07-01.8 vector aa90 applicators - maintenance 5 7 5 7 5 7 5 7 5 7 weekly weekly weekly weekly weekly • check the entire system for damage, leaks, and paint accumulation. • clean the atomizer assembly. Applica applica applica applica applicat t t t tor assembl or assembl or assembl or assembl or a...

  • Page 63

    Ah-07-01.8 vector aa90 applicators - maintenance 5 8 5 8 5 8 5 8 5 8 1. Turn off the control unit/power supply power. 2. Turn the paint and air supplies off. Relieve both fluid and air pressures. Set the trigger stop lever. 3. Unscrew the air cap retaining ring completely from the barrel. 4. With th...

  • Page 64

    Ah-07-01.8 vector aa90 applicators - maintenance 5 9 5 9 5 9 5 9 5 9 spray t spray t spray t spray t spray tip removal/carbide ip removal/carbide ip removal/carbide ip removal/carbide ip removal/carbide removal removal removal removal removal 1. Remove the retaining nut completely by hand. 2. Remove...

  • Page 65

    Ah-07-01.8 vector aa90 applicators - maintenance 6 0 6 0 6 0 6 0 6 0 figure 43: barrel removal figure 43: barrel removal figure 43: barrel removal figure 43: barrel removal figure 43: barrel removal barrel disassembly barrel disassembly barrel disassembly barrel disassembly barrel disassembly 1. Usi...

  • Page 66

    Ah-07-01.8 vector aa90 applicators - maintenance 6 1 6 1 6 1 6 1 6 1 reinstall spring reinstall spring reinstall spring reinstall spring reinstall spring figure 46b: needle shaft packing figure 46b: needle shaft packing figure 46b: needle shaft packing figure 46b: needle shaft packing figure 46b: ne...

  • Page 67

    Ah-07-01.8 vector aa90 applicators - maintenance 6 2 6 2 6 2 6 2 6 2 rebuild barrel rebuild barrel rebuild barrel rebuild barrel rebuild barrel 1. Install tip and seals into barrel. Figure 48a: rebuilding barrel figure 48a: rebuilding barrel figure 48a: rebuilding barrel figure 48a: rebuilding barre...

  • Page 68

    Ah-07-01.8 vector aa90 applicators - maintenance 6 3 6 3 6 3 6 3 6 3 4. Remove trigger lock assembly. Figure 50c: handle disassembly figure 50c: handle disassembly figure 50c: handle disassembly figure 50c: handle disassembly figure 50c: handle disassembly 5. Remove air fitting and bracket. Handle d...

  • Page 69

    Ah-07-01.8 vector aa90 applicators - maintenance 6 4 6 4 6 4 6 4 6 4 6. Remove air valve and air valve seal. Figure 50e: handle disassembly figure 50e: handle disassembly figure 50e: handle disassembly figure 50e: handle disassembly figure 50e: handle disassembly 7. Remove gasket, hook, and hook gas...

  • Page 70

    Ah-07-01.8 troubleshooting guide troubleshooting guide troubleshooting guide troubleshooting guide troubleshooting guide vector aa90 applicators - maintenance 6 5 6 5 6 5 6 5 6 5 general problem general problem general problem general problem general problem possible cause possible cause possible ca...

  • Page 71

    Ah-07-01.8 vector aa90 applicators - maintenance 6 6 6 6 6 6 6 6 6 6 general problem general problem general problem general problem general problem possible cause possible cause possible cause possible cause possible cause solution solution solution solution solution excessive surging excessive sur...

  • Page 72

    Ah-07-01.8 troubleshooting guide (cont.) troubleshooting guide (cont.) troubleshooting guide (cont.) troubleshooting guide (cont.) troubleshooting guide (cont.) general problem general problem general problem general problem general problem possible cause possible cause possible cause possible cause...

  • Page 73

    Ah-07-01.8 vector aa90 applicators - maintenance 6 8 6 8 6 8 6 8 6 8 n o t e s n o t e s n o t e s n o t e s n o t e s.

  • Page 74

    Ah-07-01.8 vector aa90 applicators - parts identification 6 9 6 9 6 9 6 9 6 9 p p p p par ar ar ar arts identifica ts identifica ts identifica ts identifica ts identification tion tion tion tion fluid hose fluid hose fluid hose fluid hose fluid hose when ordering, use 79580-a, b, c, d, and e as indi...

  • Page 75

    Ah-07-01.8 vector aa90 applicators - parts identification 7 0 7 0 7 0 7 0 7 0 p p p p par ar ar ar arts identifica ts identifica ts identifica ts identifica ts identification tion tion tion tion fluid hose fluid hose fluid hose fluid hose fluid hose when ordering, use 79581-a, b, c, d, and e as indi...

  • Page 76

    Ah-07-01.8 vector aa90 applicators - parts identification 7 1 7 1 7 1 7 1 7 1 figure 51: vector aa90 cascade exploded view figure 51: vector aa90 cascade exploded view figure 51: vector aa90 cascade exploded view figure 51: vector aa90 cascade exploded view figure 51: vector aa90 cascade exploded vi...

  • Page 77

    Ah-07-01.8 vector aa90 applicators - parts identification 7 2 7 2 7 2 7 2 7 2 1 79568-00 ring, retaining, air assist 1 2 19603-8f set screw, cup point 2 3 79460-04 assembly, plug, low voltage 1 4 79588-00 assembly, barrel aa90 with needle, retaining ring 1 79586-00 assembly, barrel aa90, barrel only...

  • Page 78

    Ah-07-01.8 figure 52: vector aa90 classic exploded view figure 52: vector aa90 classic exploded view figure 52: vector aa90 classic exploded view figure 52: vector aa90 classic exploded view figure 52: vector aa90 classic exploded view vector aa90 applicators - parts identification 7 3 7 3 7 3 7 3 7...

  • Page 79

    Ah-07-01.8 vector aa90 applicators - parts identification 7 4 7 4 7 4 7 4 7 4 1 79476-01 handle assembly 1 2 79568-00 ring, retaining, air assist 1 3 19603-8f set screw, cup point 2 4 77096-00 fluid tube assembly, 1 5 76105-00 swivel, high pressure 1 6 79584-00 assembly, barrel, aa90 classic with ne...

  • Page 80

    Ah-07-01.8 vector aa90 applicators - parts identification 7 5 7 5 7 5 7 5 7 5 figure 53: accessories figure 53: accessories figure 53: accessories figure 53: accessories figure 53: accessories * the "accessories" are included with each classic or cascade unit 1 79676-00 wrench, nozzle removal 1 2 74...

  • Page 81

    Ah-07-01.8 vector aa90 applicators - parts identification 7 6 7 6 7 6 7 6 7 6 figure 54: 7994-xx fluid line figure 54: 7994-xx fluid line figure 54: 7994-xx fluid line figure 54: 7994-xx fluid line figure 54: 7994-xx fluid line 7994-xx fluid line 7994-xx fluid line 7994-xx fluid line 7994-xx fluid l...

  • Page 82

    Ah-07-01.8 3 2 1 1 79566-10 assembly, fan air adjust 1 (contains #2 and #3) 2 79001-16 o-ring, solvent proof 1 3 79001-07 o-ring, viton 1 item # item # item # item # item # part # part # part # part # part # description description description description description q t y q t y q t y q t y q t y f ...

  • Page 83

    Ah-07-01.8 7 8 7 8 7 8 7 8 7 8 vector aa90 applicators - parts identification 10 11 7 8 11 2 4 1 3 6 5 figure 57: 79513-13x control unit figure 57: 79513-13x control unit figure 57: 79513-13x control unit figure 57: 79513-13x control unit figure 57: 79513-13x control unit -- 79513-132 assembly, cont...

  • Page 84

    Ah-07-01.8 vector aa90 applicators - parts identification 7 9 7 9 7 9 7 9 7 9 figure 58: aa90 classic power supply figure 58: aa90 classic power supply figure 58: aa90 classic power supply figure 58: aa90 classic power supply figure 58: aa90 classic power supply -- 79344-141 power supply, 110/120 v ...

  • Page 85

    Ah-07-01.8 vector aa90 applicators - parts identification 8 0 8 0 8 0 8 0 8 0 10051-05 cup seal, spring loaded 1 1 17130-00 return spring 1 1 72209-05 o-ring 1 1 72375-02 seal, teflon 1 1 72375-03 seal, teflon 1 1 72378-01 packing tube 1 1 73344-00 seal, spreader 1 1 73345-00 u-cup seal 1 1 73347-00...

  • Page 86

    Ah-07-01.8 vector aa90 applicators - warranty policies 8 1 8 1 8 1 8 1 8 1 w w w w warranty arranty arranty arranty arranty policies policies policies policies policies limited w limited w limited w limited w limited warranty arranty arranty arranty arranty itw ransburg will replace or repair withou...

  • Page 87

    Ah-07-01.8 manual manual manual manual manual change summar change summar change summar change summar change summary y y y y this manual was published to replace service manual ah-07-01.7 ah-07-01.7 ah-07-01.7 ah-07-01.7 ah-07-01.7 vector aa90 applicators, to make the following changes: 1. Corrected...

  • Page 88

    Form no. Ah-07-01.8 litho in u.S.A. 06/10 © 2010 illinois tool works inc. All rights reserved. Models and specifications subject to change without notice. Manufacturing manufacturing manufacturing manufacturing manufacturing 1910 north wayne street angola, indiana 46703-9100 telephone: 260/665-8800 ...