  • Page 1

    Toilet installation and maintenance instructions 1-800-352-5630 www.Raritaneng. Com desription: marine elegance toilet is available in 12v or 24v dc. Bowls are available in four models: standard with angled back, standard with straight back, tall with angled back and tall with straight back.Fresh wa...

  • Page 2: Safety

    Safety 2 important safety instructions: warning: young children should not be left unsupervised around toilet. Serious injury or death could occur. Children can drown in water retained in the bowl. Seat and/or lid could close and strike child. Always replace circuit breaker and fuses with same ratin...

  • Page 3: Operation

    Operation 3 a. Push button switch: press push-button switch and hold until all waste is cleared from the toilet bowl. B. Me toilet control: 1. Press and hold “water only” to add water to the bowl 2. Press and hold “empty” to evacuate the bowl 3. Press and hold “flush” to bring water in while bowl is...

  • Page 4: Operation

    Operation 4 note : flush control is set at factory to work in most installations and no additional programming is needed. Use following instructions to re-program if adjustment on water levels and timings are needed. Programming timing for “normal” flush cycle: normal cycle has initial fill time (t1...

  • Page 5: Winterizing

    Winterizing winterizing: • improper winter lay up is a major cause of marine toilet failure. • use only nontoxic antifreeze. • flush toilet several times to clear waste from system. • dispose of all antifreeze in accordance with local and federal regulations. • winterize holding tanks, plumbing, tre...

  • Page 6: Specifica

    Specifica tions 6 pressurized freshwater model - recommended wire and fuse/circuit breaker size sea water model - recommended wire and fuse/circuit breaker size plumbing notes: for wiring t e e f 0 1 5 1 0 2 5 2 0 3 0 4 0 5 r e t e m 1 . 3 6 . 4 1 . 6 6 . 7 2 . 9 2 . 2 1 2 . 5 1 p m u p e k a t n i ...

  • Page 7: Specifications

    7 specifications additional parts required • 1" (25 mm.) or 1 1/2" (38 mm.) i.D. Discharge hose • 3/4" (19 mm.) i.D. Reinforced intake hose • 3/4" (19 mm.) and 1" (25 mm.) or 1 1/2" (38 mm.) hose clamps (two for each connection below waterline) • wire • terminals • fuse/circuit breaker 14 note: 12 1...

  • Page 8: Mounting

    8 mounting a. Preparation for mounting toilet mounting surface must be flat and solid. Seat must open more than 90 degrees. 1. Place the toilet and mark mounting holes’ center line, and outside of the bowl (see fig 1.) draw a center line between two holes. Mark front hole outside and center and draw...

  • Page 9: Plumbing

    Discharge lines 1. Connect quality sanitation hose 1" (25 mm.) or 1 1/2”(38 mm.) discharge fitting on toilet. 2. Run hose to appropriate device (i.E.: treatment system, holding tank, etc.). Inlet lines 1. Connect 1/2”(13 mm.) hose to pressurized supply or 3/4”(19 mm.) hose to remote pump plumbing b....

  • Page 10: Plumbing

    10 plumbing intake lines pressurized freshwater models install a shut off valve in intake line before water solenoid valve. 1. Connect hose from shut off valve to inlet port of water solenoid valve at the toilet. Note: to avoid malfunction of water solenoid due to debris in water, installation of fr...

  • Page 11: Wiring

    Wiring c. Mounting controls: a. Push button switch: (see fig 11) • mount push button switch in an accessible location. • make certain wires can be routed to push button switch. • wire terminals must have clearance when installed. 1. Drill 5/8" (16mm) hole. 2. Attach wires to push button switch termi...

  • Page 12: Wiring

    12 d. Wiring warning: hazard of shock and fire • always use proper wire, wire connectors and fuse/circuit breaker. See specification chart. • secure wire properly. • do not connect appliances to toilet circuit. • make sure power is off before proceeding. • use proper wire terminals for all wire conn...

  • Page 13: Wiring

    Wiring battery fuse red orange black red black solenoid valve discharge pump fig. 14 wiring for push button switch fresh water model to est discharge pump black red blue blue black red fuse pump relay red push button push button battery 13 fig. 14a wiring for push button switch remote pump model to ...

  • Page 14: Wiring

    Wiring 14 gnd valve- orange black red black red black ba tt - pump - est valve + pump + ba tt + panel holding tank full from est to est ext trig batt flush control panel fuse/breaker orange black red black red black panel tank full switch est input batt flush control panel fuse/breaker relay pump re...

  • Page 15: Wiring

    15 wiring orange black black red black red flush control panel fuse/breaker batt control box batt red blue flush control panel pump fuse/breaker red orange black blue black red red relay fig. 18 wiring for me toilet control with remote pump fig. 17 wiring for me toilet control freshwater model solen...

  • Page 16: Installation

    16 5. Route wire from control per wiring diagrams. 6. Install seat. I nstall discharge support strap between seat nut and the bowl per fig. 19a. 7. Install toilet in place, connect hoses and wireplugs. (see fig. 19) caution: do not pull on the discharge hose to avoid kinking 8. Install mounting bush...

  • Page 17: Troubleshooting

    17 troubleshooting warning: hazard of electric shock - before beginning any work on the toilet, be sure that all power to the unit has been turned off. Warning: hazard of flooding - make sure seacocks are in the closed or off position before work- ing on toilet. Note: the following information refle...

  • Page 18: Exploded Parts

    Exploded parts marine elegance parts list 221100 toilet bowl,standard, angled, white(1) 221100a toilet bowl bone(1) 2210012 discharge pump assembly (1) 221012 motor: 12 vdc (1) 221024 motor: 24v dc (1) 221105 o-ring (1) 221110 discharge pump seal plate (1) 221115 discharge pump macerator housing(1) ...

  • Page 19: Exploded Parts

    Marine elegance exploded parts view 1222aw f172 f005 162325a 162305 162320 162310 162315 162420 162405 162415 162410 162425 f144 f162vt 163000 1660* m23a 162300w 162425 162425 162225 162135 162100w 162420 162200w 190601 - recommended exploded parts f193 freshwater strainer recommended seawater strai...

  • Page 20

    L460 0610vkm specifications subject to change without notice printed in u.S.A. 530 orange street, millville, nj 08332 usa telephone: 856-825-4900 fax: 856-825-4409 www.Raritaneng.Com southern office and plant: 3101 sw second avenue, fort lauderdale, fl 33315 usa telephone: 954-525-0378 fax: 954-764-...