    1 1-800-352-5630 www.Raritaneng. Com important safety instructions for handling purasan ® tablets and solution warning: hazard of dangerous chemical reaction 1. Use only purasan tablets. 2. Do not add any other chemicals or cleaning products to the toilet or the treatment system. Raritan c.P. - clea...

  • Page 2: Opera

    2 opera tion (depends on installation chosen) single button operation - both toilet and purasan are operated by one of the following options: option #1: switch panel "push to cycle" button activates both the toilet and treatment cycle. Note: toilet flush time is set at 10 seconds, after initial 10 s...

  • Page 3: Maintenance

    3 maintenance use only purasan tablets. Do not add any other chemicals or cleaning products to the toilet or the treatment system. Raritan c.P. - cleans potties and r.C. Raritan concentrate are the only factory-recognized cleaning products that may be used in the toilet. Maintenance warning: read an...

  • Page 4: Winterizing

    4 winterizing tablet dispenser 1. Close flow metering clamp and disconnect power to water solenoid, if used, to prevent intake wa- ter from entering tablet dispenser. 2. Flush toilet and activate treatment cycle several times to leave just water in tank. 3. Carefully remove small tube from white “t”...

  • Page 5: Recommissioning\st

    5 recommissioning\st art -up recommissioning important: • do not load tablet cartridge into dispenser until system is powered and operational. • do not operate purasan until treatment unit is filled with water. Treatment tank 1. Reconnect hoses and open seacocks. 2. Reconnect wires and turn power on...

  • Page 6: Specifica

    6 specifica tions u.S.C.G. Type i msd certification #159.015/106/0 maximum roll/pitch angle: 30° maximum temperature exposure: 120° f (49° c) maximum total flush volume: 1.5 gallons/flush (5.7 liters/flush) water - fresh, salt or brackish conversions wire - awg to mm 2 feet to meters t e e f 0 1 5 1...

  • Page 7: Inst

    7 inst alla tion mounting treatment tank warning: do not locate in an area where ambient temperature exceeds 120 o f (49 o c). 1. Locate top of treatment tank at or below discharge of toilet and within six feet (1.5 m). Note: if mounting treatment tank higher than discharge. Contact raritan 2. Make ...

  • Page 8: Inst

    8 inst alla tion raw water toilets - 1. Turn off power to toilet. 2. Close intake and discharge seacocks and drain water from toilet system. 3. Disconnect intake hose from bowl elbow. 4. Remove existing bowl elbow and install new bowl elbow supplied with purasan. 5. Insert the “t” fitting in the hos...

  • Page 9: Wiring

    9 wiring wiring warning: hazard of shock and fire • always use proper wire, wire connectors and fuse/circuit breaker. See specification chart. • secure wire properly. • do not connect other appliances to purasan circuit. • make sure power is off before proceeding. • improper wiring can damage the ci...

  • Page 10: Wiring

    10 wiring flushing option #1: "push to cycle" button activates both the toilet and treatment cycle. Note: toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will momentarily flush the toilet. 1. Mount switch panel near toilet. Caution: use only the raritan #cds ...

  • Page 11: Troubleshooting

    11 troubleshooting troubleshooting warning: after the tablet dispenser has had water added, it contains a very strong halogen solution. Always wear protective gloves and ventilate well to work on tablet dispenser. Before doing any maintenance or repairs, follow winterizing/storage procedures no wate...

  • Page 12: Exploded P

    12 exploded p arts 10 17 18 8 7 21 63 64 56 43 45 6 42 43 47 49 32 31 29 28 53 23 55 50 23 23 24 22 41-100

  • Page 13: Exploded P

    13 exploded p arts purasan parts list item part # description 50 41-110 vent kit for tablet dispenser (incl. #53, 54, & 55) 51 m31 #14 brass flat washer (4) 52 m30 1/4"-20 brass nut (4) 41-100 tablet dispenser complete(less cartridge) 41-200 t-fitting (incl. #33, 34, 37 &38) 42-1000 treatment unit c...

  • Page 14: Dual

    14 dual installation - “push button” also activates purasan - pbs battery 3 amp fuse small post on cds to s2 and pbs cds to toilet positive (+) purasan circuit board on t reatment tank freshwater solenoid valve wiring battery dual inst alla tion important: • dual toilet installations require either ...

  • Page 15

    15 note: discharge of raw, untreated sewage is prohibited in all u.S. Waters inside the three mile limit except in the gulf of mexico where the limit is nine miles. "y" valves, if installed, must direct toilet discharge to a u.S.C.G. Approved treatment system or holding tank and must be secured in t...

  • Page 16

    16 l405 0911kgs specifications subject to change without notice printed in u.S.A. 530 orange street, millville, nj 08332 usa telephone: 856-825-4900 fax: 856-825-4409 website: www.Raritaneng.Com southern office and plant: 3101 sw second avenue, fort lauderdale, fl 33315 usa telephone: 954-525-0378 f...