  • Page 1

    Pressurized freshwater model sea water model (remote pump) sea water model (integral pump) the seaera toilet is a powerful centrifugal macerating toilet that thoroughly breaks down waste. Seaera toilet operation, maintenance and installation instructions the following are cautionary statements that ...

  • Page 2: Opera

    Press push-button switch and hold until all waste is cleared from the toilet bowl. • no special toilet paper is required. • water should appear in the bowl within ten seconds. If not, see troubleshooting section. • hard objects or stringy substances (paper towels, feminine hygiene products, filter c...

  • Page 3: Maintenance

    Clean gasket and gasket contact surfaces thoroughly unscrew tighten cleaning instructions important: do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These may cause damage to the toilet. Using c.P. A bio-enzymatic toilet bowl cleaner (availab...

  • Page 4: Winterizing

    Winterizing important • improper winter lay up is a major cause of marine toilet failure. • use only nontoxic antifreeze. • flush toilet several times to clear waste from system. • dispose of all antifreeze in accordance with local and federal regulations. • winterize holding tanks, plumbing, treatm...

  • Page 5: Winterizing

    Integral and remote intake pump models parts required 3/4" (19mm) i.D. Intake hose approximately 3 feet (1m) long. 1" (25mm) or 1 1/2" (38mm) i.D. Discharge hose approximately 3 feet (1m) long. Two buckets nontoxic antifreeze approximately 1 quart (1 liter) steps 1. Close the intake and discharge se...

  • Page 6: Specifica

    Specifica tions pressurized freshwater model - recommended wire and fuse/circuit breaker size 6 5/8" (16.8cm) 19 3/4" (52.1cm) household 17 1/2" (44.5cm) marine 14 3/8" (36.5cm) household 13" (33cm) marine 11 1/8" (28.3cm) 14 7/8" (37.8cm) household 14 1/2" (36.8cm) marine 14 7/8" (37.8cm) household...

  • Page 7: Inst

    7 mounting toilet mounting surface must be flat and solid. 1. Install seat on toilet. 2. Remove motor cover. 3. Place toilet where it will be located. Make sure there is room to route hoses. Make sure seat will open properly. 4. Mark location of toilet base mounting holes on mounting surface. 5. Dri...

  • Page 8: Inst

    8 90° rotation of toilet bowl toilet bowl can be rotated 90° on the base, for installing in confined locations. Note: seaera models with integral pump: replace existing hose from the intake pump to the toilet bowl with a longer hose. 1. Determine which direction bowl is to be mounted. 2. Remove hose...

  • Page 9: Inst

    Inst alla tion mounting water solenoid valve (pressurized freshwater models only) 1. Locate valve on a solid flat surface in an area that is dry and well ventilated. 2. Mark and drill holes for water solenoid mounting bracket. Note: hole size will depend on type of bolts/screws used (1/4" [6mm] size...

  • Page 10: Inst

    10 inst alla tion discharge lines 1. Connect quality sanitation hose 1" (25mm) or 1 1/2" (38mm) i.D. To discharge fitting on toilet. 2. Run hose to appropriate device (i.E.: treatment system, holding tank, etc.). Plumbing warning: hazard of flooding toilets mounted at or below the waterline must hav...

  • Page 11: Inst

    11 from seacock to intake pump inst alla tion intake lines pressurized freshwater models install a shut off valve in intake line before water solenoid valve. 1. Connect hose from shut off valve to inlet port of water solenoid valve. Note: to avoid malfunction of water solenoid due to debris in water...

  • Page 12: Wiring

    Wiring warning: hazard of shock and fire • always use proper wire, wire connectors and fuse/circuit breaker. See specification chart. • secure wire properly. • do not connect appliances to toilet circuit. • make sure power is off before proceeding. • use proper wire terminals for all wire connection...

  • Page 13: Oubleshoo

    Troubleshooting warning: hazard of electric shock - before beginning any work on the seaera, be sure that all power to the unit has been turned off. Warning: hazard of flooding - make sure seacocks are in the closed or off position before working on toilet. Note: the following information reflects t...

  • Page 14: Exploded P

    Exploded p a r t s part no. Description 1108a macerator nut 1222aw 90° discharge fitting 1226 mounting screw (4) 1226b 1/4-20 hex nut (4) 1234 bowl gasket 1236aw bowl spud assembly 1236e bowl elbow 1237 marine-size bowl 1244 household-style bowl 1610* motor 161105 base 161107 seal plate o-ring 16111...

  • Page 15: Exploded P

    15 exploded p a r t s seaera exploded parts view 1244 or 1237 1236aw 1236e 1234 vcap 1226b rni ch38 161105 c254 161130 1222aw 161125 f164 161107 1108a m23a 161123 161120 161115 31-102 161110 1610* hw1 1226 161135 or 161140 164000 f020 f005 162325a 162305 162320 162310 162315 162420 162405 162415 162...

  • Page 16

    L318 0103kgs specifications subject to change without notice printed in u.S.A. 530 orange street, p.O. Box 1157, millville, nj 08332 usa telephone: 856-825-4900 fax: 856-825-4409 www.Raritaneng.Com southern office and plant: 3101 sw second avenue, fort lauderdale, fl 33315 usa telephone: 954-525-037...