Rasmussen AGA Chillbuster IR Assembly, Installation And Operation Instructions

Summary of AGA Chillbuster IR

  • Page 1

    Aga "chillbuster ir" 12028 e. Philadelphia st. Whittier , ca 90601 u.S.A. (562) 696-8718 fax (562) 698-3510 e-mail: gaslogs@riwinc.Com web http://www.Riwinc.Com form cbir-2-02 assembly, installation, and operation instructions for rasmussen "infra-red" gas log room heater" (c-r) manual, switch, or r...

  • Page 2

    All applications (installation) all applications-important notice • children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. • young children should be carefully supervised when they are in the same room with the applia...

  • Page 3

    All applications (installation) fireplace/firebox sizing (vented and vent-free): 1. The minimum size (in inches) of the fireplace in which this chillbuster is to be installed must be as follows: s e t s i z e m o d e l number front width height d e p t h 18 24 24 30 (k,w)(18)-cra-(m,t)-(n,p) (30,000...

  • Page 4

    Vent-free applications (additional requirements) 1. Do not use this chillbuster as a vent free heater in sleeping quarters, bathrooms or recreational vehicles. 2. When operated as a vent free heater, the minimum clearances from the fireplace opening to combustible materials must be maintained as out...

  • Page 5

    Vent-free applications (additional requirements) combustion air calculations worksheet 1 . Room width length height w x l x h=vol. (ft3) 1 a . 1 b . 1 c . 1 d . 2 . Total volume (ft3 )sum of volume (ft3) of all rooms (sum lines 1a. Thru 1d.) 2 . 3 . Max supportable btu/hr=total volume (ft3) ÷ 50 x 1...

  • Page 6

    Vent-free applications (additional requirements) fireplace hoods (vent-free) a fireplace hood deflects heat away from the fireplace face and mantel, reducing the potential for heat related warping or discoloration. The use of a fireplace hood is highly recommended. Fireplace hoods are offered by man...

  • Page 7

    All applications (vented and vent free operation) infra-red direct heat clearances to combustibles and direct heat comfort zone clearances to combustibles: do not locate any combustible material within 24" of the front of the solid fuel burning enclosure in which you have installed your chillbuster ...

  • Page 8: . . .

    All applications (vented and vent free operation) cra-m and crb-m (manual control) pilot lighting, operation, and shutting down: infra-red (front) burner on - off valve off on figure 8 pilot lighting: 1. Slightly push gas control valve (figure 9) knob and turn to “s e a s o n o f f ”. 2. Wait five m...

  • Page 9

    All applications (vented and vent free operation) cbr-t (thermostatic control) pilot lighting, operation, and shutting down: pilot lighting: 1. Turn knob "a" (main gas control) clockwise to "o f f " position. S e e f i g u r e 1 1 . 2. Turn knob "b" (rear gas burner thermostat) clockwise to lowest s...

  • Page 10

    All applications (vented and vent free operation) thermostat sensor bulb placement: 1. The thermostat sensor bulb should be placed where it can best sense average air temperature of the room in which the appliance is installed. 2. Proper operation of the thermostat can be checked by placing the ther...

  • Page 11

    How to order parts parts can be ordered through the supplier from whom you purchased your log set. When ordering parts, always specify (from information available on name plate attached to grate) the following: 1. Model number of the log set. 2. Serial number of the log set. 3. Type of gas (natural ...

  • Page 12

    Two year consumer product warranty the following warranty has been drafted to comply with the magnuson-moss warranty act applicable to products manufactured after july 4, 1975. It replaces and supersedes any warranty in this package or in any printed literature. Limited warranty: rasmussen iron work...

  • Page 13

    . . . Knob b pilot set screw under plate here. Off on knob a main gas control knob b rear gas burner thermostat knob c infra-red front burner valve 13.